The Library

1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.

Papers 301–323 of 323 labelled “venous-agreement”, newest first.

  1. 2017

    Clinical validation in twenty-eight children showed that dried blood spot sampling predicted venous tacrolimus concentrations adequately, with ninety-five percent of predicted-to-observed ratios between 0.74 and 1.28 and median prediction error below fifteen percent, whereas mycophenolic acid predictions were more variable, indicating semiquantitative utility. The authors concluded that home-based dried blood spot collection is suitable for tacrolimus therapeutic drug monitoring in paediatric transplant recipients.

    Dried Blood Spot Sampling for Tacrolimus and Mycophenolic Acid in Children: Analytical and Clinical ValidationMartial et al., Therapeutic drug monitoring (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • pediatric
    • tdm
    • immunosuppressants
  2. 2017

    Dried VAMS and DBS samples collected at home and analysed after a median of three days showed poor agreement with standard venous or capillary blood for HbA1c monitoring. In contrast, wet VAMS samples analysed immediately demonstrated excellent agreement, indicating that sample drying and delayed analysis compromise reliability for decentralised HbA1c measurement.

    Volumetric absorptive microsampling at home as an alternative tool for the monitoring of HbA1c in diabetes patientsVerougstraete et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • vams
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • pediatric
  3. 2016

    With Oragene DISCOVER self-collection, saliva SNP-array genotypes matched blood at 99.996% concordance; about 6% of samples failed on low yield, so an occasional repeat should be expected.

    Saliva DNA quality and genotyping efficiency in a predominantly elderly populationGudiseva et al., BMC Medical Genomics

    • dna
    • venous-agreement
    • stabilised
    • blood
    • dna-genotek-oragene
    • validation
    • saliva
    • genotyping
  4. 2016

    ORAcollect saliva matched blood at 97.9% overall variant concordance on a hereditary-cancer NGS panel, rising to 100% for protein-coding variants, supporting self-collected saliva for germline testing.

    Validation of saliva as an alternative specimen for detecting hereditary breast-cancer mutations by next-generation sequencingMeghnani et al., International J. Genomics

    • dna
    • venous-agreement
    • stabilised
    • blood
    • dna-genotek-oracollect
    • validation
    • saliva
    • genotyping
  5. 2016

    Saliva collected with the Oragene DISCOVER kit from 30 patients with pheochromocytoma or paraganglioma produced DNA concentrations comparable to paired venous blood, though with slightly lower purity from protein contamination. Saliva is a viable alternative to blood for germline screening of SDHB and SDHD mutations in this population.

    SDH Subunit Mutation Status in Saliva: Genetic Testing in Patients with PheochromocytomaOsinga et al., Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme (paywalled)

    • saliva
    • dna-genotek-oragene
    • venous-agreement
    • genotyping
  6. 2016

    The Infopia Element blood glucose meter showed acceptable precision, linearity and interference performance and met ISO 15197 accuracy criteria with 100 per cent of results in Clarke and consensus error grid zones A and B, but it exhibited a positive bias at low to mid glucose concentrations that may require further improvement for home use.

    Analytical Performance Evaluation of Infopia Element™ Auto-coding Blood Glucose Monitoring System for Self-Monitoring of Blood GlucosePark et al., Journal of clinical laboratory analysis (paywalled)

    • blood
    • liquid
    • capillary
    • venous-agreement
  7. 2016

    In children with type 1 diabetes, ambulatory glucose profile showed mean absolute relative difference of 9.56% versus laboratory random glucose and 15.07% versus capillary glucose, with linear regression coefficients of 0.93 and 0.89 respectively, indicating acceptable agreement for outpatient glycaemic monitoring.

    Evaluation of accuracy of ambulatory glucose profile in an outpatient setting in children with type 1 diabetesHulse et al., Indian journal of endocrinology and metabolism

    • blood
    • liquid
    • capillary
    • venous-agreement
    • pediatric
    • cgm
    • multimodal
  8. 2016

    DBS sampling yielded drug concentrations that agreed with plasma at 79–94% for praziquantel enantiomers and 108–122% for its metabolite in nine opisthorchiasis patients. This validates DBS as a practical alternative to conventional venous sampling for therapeutic drug monitoring in resource-limited settings.

    Pharmacokinetic Study of Praziquantel Enantiomers and Its Main Metabolite R-trans-4-OH-PZQ in Plasma, Blood and Dried Blood Spots in Opisthorchis viverrini-Infected PatientsMeister et al., PLoS neglected tropical diseases

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
  9. 2016

    Miltefosine concentrations measured in dried blood spots showed excellent agreement with plasma (median ratio 0.99, Pearson's r=0.946) in patients with visceral leishmaniasis. The method demonstrated 97% extraction recovery, remained stable for 162 days at 37°C, and performed reliably across haematocrit levels of 20–35%, offering a valid and practical alternative to venous sampling for therapeutic drug monitoring in decentralised settings.

    Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample CollectionKip et al., Antimicrobial agents and chemotherapy

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • haematocrit
  10. 2016

    The validation of a dried blood spot assay for ceftriaxone achieved a limit of quantification of 0.14 mg/L with strong correlation between DBS-predicted and measured plasma concentrations (r=0.95). The method showed acceptable thermal stability, retaining over 95% of initial concentrations for periods ranging from 14 hours to 11 months. This supports the use of self-collected DBS samples for therapeutic drug monitoring of antimicrobials in remote and resource-poor settings.

    Validation and Application of a Dried Blood Spot Ceftriaxone AssayPage-Sharp et al., Antimicrobial agents and chemotherapy (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • haematocrit
  11. 2015

    Capillary dried blood spots collected at home by pediatric transplant patients and mailed to the laboratory gave tacrolimus and sirolimus results that were clinically comparable to venous whole blood, with small negative biases within acceptable limits, enabling remote therapeutic drug monitoring.

    Tacrolimus and sirolimus in capillary dried blood spots allows for remote monitoringDickerson et al., Pediatric transplantation (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • venous-agreement
    • pediatric
    • tdm
    • immunosuppressants
  12. 2015

    Capillary thyroid stimulating hormone values in the 4-6 mU/L range in children with Down syndrome rarely indicate true hypothyroidism, as venous free thyroxine was normal in almost all cases. The authors propose a decentralised screening algorithm that uses repeat finger-prick testing after six months rather than venepuncture for school-aged children with borderline elevations, which could reduce patient burden and support patient-centric care.

    Screening for hypothyroidism in Down syndrome using the capillary thyroid stimulating hormone methodMcGowan et al., The Journal of pediatrics (paywalled)

    • blood
    • capillary
    • venous-agreement
    • pediatric
    • hormones
  13. 2015

    MiniCollect 3.2% citrate small-volume tubes give PT/INR results equivalent to standard venipuncture and are suitable when a small blood volume is preferred; EDTA tubes do not agree with standard sampling.

    Evaluation of small-volume tubes for venous and capillary PT (INR) samplesOnelöv et al., International journal of laboratory hematology (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
    • pediatric
  14. 2015

    Retinol measured in dried blood spots showed high agreement with venous plasma (r=0.9724) and remained stable at room temperature for up to 10 weeks when extracted under acidic conditions, enabling simple and reliable assessment of vitamin A status for population studies and large clinical trials.

    Robust measurement of vitamin A status in plasma and blood dried on paperHuang et al., Prostaglandins, leukotrienes, and essential fatty acids (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • biomarkers
  15. 2015

    The study validated a commercial ELISA for measuring measles-specific IgG in capillary dried blood spots from children, finding 100% sensitivity and 96.8% specificity against matched venous serum with 92% overall agreement, then applied the method to 1,588 field-collected samples in Mexico and Nicaragua. The procedure was acceptable to surveyors and participants, showing that dried blood spots are a feasible and accurate means of assessing population immunity to measles in low-resource settings.

    Use of a commercial ELISA for the detection of measles-specific immunoglobulin G (IgG) in dried blood spots collected from children living in low-resource settingsColson et al., Journal of medical virology (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • acceptability
    • pediatric
    • serology
  16. 2015

    Dried capillary blood spot screening correctly identified 95.5% of relatives with multiple islet autoantibodies and 98.6% of those without, and 60% of participants favoured initial home fingerstick screening with clinic visits only if autoantibodies were found.

    Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility StudyBingley et al., Diabetes technology & therapeutics (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
  17. 2015

    Self-collected dried blood spots gave HbA1c measurements that agreed closely with venous blood when samples were stored at room temperature for up to seven days, showing low intra-assay variation and clinically acceptable prediction intervals. The method offers a viable alternative for diabetes monitoring in remote or home-bound populations where traditional venepuncture is unavailable.

    The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional studyMastronardi et al., BMC clinical pathology

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
  18. 2014

    Dried blood spot microsampling provides a patient-centric alternative to venous sampling for therapeutic drug monitoring, with advantages of home self-collection, small sample volumes suitable for children, and analyte stability, though accuracy is affected by haematocrit and requires patient correlation studies to validate clinical equivalence.

    Therapeutic drug monitoring by dried blood spot: progress to date and future directionsWilhelm et al., Clinical pharmacokinetics

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • pediatric
    • tdm
    • haematocrit
  19. 2014

    Capillary earlobe blood (20 µl) from adults yielded RNA expression results comparable to venous blood for four mRNAs and microRNA‑126. This microsampling approach may enable gene expression profiling in newborns, children and patients requiring repeated sampling or with bleeding disorders.

    Capillary earlobe blood may be used for RNA isolation, gene expression assays and microRNA quantificationWehmeier & Hilberg, Molecular medicine reports (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
    • pediatric
  20. 2014

    Finger‑prick dried blood spots gave almost identical nandrolone and testosterone concentrations to venous samples. Home self‑collection for 21 days was well tolerated, showing that microsampling supports decentralised therapeutic drug monitoring without clinic visits, venesection or frozen storage.

    Pharmacokinetic-pharmacodynamic study of subcutaneous injection of depot nandrolone decanoate using dried blood spots sampling coupled with ultrapressure liquid chromatography tandem mass spectrometry assaysSingh et al., The Journal of clinical endocrinology and metabolism (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • venous-agreement
    • hormones
    • tdm
  21. 2014

    Parsons et al. validated a quantitative dried blood spot assay for rifapentine that remained stable for 11 weeks at ambient temperature and showed good agreement with plasma concentrations after haematocrit correction, offering a low-volume sampling approach suitable for therapeutic drug monitoring in international and paediatric tuberculosis trials.

    Quantification of rifapentine, a potent antituberculosis drug, from dried blood spot samples using liquid chromatographic-tandem mass spectrometric analysisParsons et al., Antimicrobial agents and chemotherapy (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • haematocrit
  22. 2014

    Both the Sebia CAPILLARYS 2 Flex Piercing and the Tosoh G8 performed excellently for HbA1c determination with low imprecision and minimal bias. Capillary blood analysed on the Cap 2FP showed good agreement with venous blood and was stable at room temperature, making it an acceptable alternative for point of care testing and enabling home collection with central analysis to reduce healthcare costs without compromising quality.

    Evaluation of the Sebia CAPILLARYS 2 flex piercing for the measurement of HbA(1c) on venous and capillary blood samplesHeylen et al., American journal of clinical pathology (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
  23. 2014

    A patient-use blood glucose monitoring system achieved accuracy comparable to six professional-use point-of-care systems when capillary samples from 100 subjects were measured by trained staff under standardised conditions, with all seven systems showing 99.5 to 100 per cent of results within ISO 15197:2003 limits. This supports the case that decentralised, patient-centric capillary blood glucose measurement can match professional laboratory-aligned performance when sampling is standardised.

    System accuracy evaluation of systems for point-of-care testing of blood glucose: a comparison of a patient-use system with six professional-use systemsFreckmann et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement