Skip to content
OpenSampling

The Library

1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.

Papers 1–100 of 757 labelled “validation”, newest first.

  1. 2026

    In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.

    Clinical Validation of Venetoclax Volumetric Microsampling in Leukemia, with Whole-Blood-to-Plasma Conversion and Self-Microsampling FeasibilityLevens et al., Clinical Pharmacokinetics (paywalled)

    • vams
    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • capillary
    • validation
  2. 2026

    Guidance on capillary-to-plasma conversion: method- and analyte-specific clinical validation with paired capillary–venous samples before reporting plasma-equivalent results.

    To Convert or Not to Convert? Official IATDMCT Guideline on Converting Capillary-Blood Microsampling Concentrations to Plasma ConcentrationsBoffel et al., Therapeutic Drug Monitoring (paywalled)

    • venous-agreement
    • blood
    • tdm
    • standards
    • dried
    • capillary
    • validation
  3. 2026

    Saliva samples collected using the OMNIgene ORAL device and oral wash samples remain stable for microbiome diversity and relative abundance analyses for up to five years when stored at -80°C. This supports the use of these self-collection methods for long-term prospective biobanking and decentralised clinical studies.

    Long-term stability at -80°C of oral wash and saliva samples for microbiome analysesSlack et al., Microbiology spectrum (paywalled)

    • stabilised
    • dna-genotek-omnigene
    • self-collection
    • microbiome
    • liquid
    • validation
    • saliva
  4. 2026

    This meta-analysis found that HPV testing using self-collected vaginal and urine samples showed sensitivities of 88.6% and 81% for detecting cervical precancer. Using a standardised device for first-void urine increased sensitivity to 86.6%, supporting decentralised patient-centric screening, though data on specificity and specific commercial devices were not consistently reported.

    Diagnostic Performance of HPV Testing Using Self-Collected Urine and Vaginal Samples for Detecting Cervical Precancer or Worse: A Meta-AnalysisHsiao et al., The journal of obstetrics and gynaecology research (paywalled)

    • urine
    • first-void
    • self-collection
    • validation
    • hpv
    • sti
  5. 2026

    This meta-analysis found that self-collected urine samples for HPV testing had lower sensitivity for detecting high-grade lesions compared to physician-collected cervical specimens. The use of a first-void collection device such as Colli-Pee was associated with marginally higher sensitivity than general urine sampling.

    Accuracy of HPV Testing Using Self-collected Urine Compared With Physician-collected Cervical Specimen for HSIL or WorseChen et al., Journal of lower genital tract disease (paywalled)

    • urine
    • first-void
    • colli-pee
    • self-collection
    • validation
    • hpv
    • sti
  6. 2026

    The analysis indicates that dried blood spots and volumetric absorptive microsampling enable minimally invasive monitoring of prohibited substances, with volumetric absorptive microsampling offering improved quantitative reliability over traditional dried spots.

    Liquid Chromatographic Methods for Microsampling in Sports Drug Monitoring: Progress in DBS and VAMSZhang, Biomedical chromatography : BMC (paywalled)

    • vams
    • doping
    • blood
    • dbs
    • dried
    • steroids
    • toxicology
    • hormones
    • validation
    • biomarkers
  7. 2026

    Researchers successfully validated an analytical method for measuring creatinine across plasma and volumetric absorptive microsampling devices, demonstrating strong correlation between conventional plasma and dried microsamples. This provides a reliable, patient-centric approach for monitoring kidney function remotely during transplant follow-up.

    Surrogate-based LC-MS/MS quantification of endogenous creatinine in plasma, plasma-equivalent dried spots (qDPS), and volumetric absorptive microsampling (VAMS): an ICH M10-compliant bridging studyKocur et al., European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences (paywalled)

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dried
    • validation
    • biomarkers
  8. 2026

    In lung and renal transplant recipients, VAMS sampling with LC-MS/MS quantification of mycophenolic acid and tacrolimus showed good linearity and accuracy, and with a haematocrit-adjusted conversion formula achieved clinical agreement in most samples; tacrolimus did not require haematocrit correction. The approach is virtually painless and enables richer sampling for more accurate drug exposure estimates, supporting decentralised therapeutic drug monitoring.

    Evaluation of hematocrit-adjusted conversion strategies for mycophenolic acid and tacrolimus monitoring using volumetric absorptive microsampling in lung and renal transplant recipientsJuan et al., Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit
  9. 2026

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug MonitoringHuhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled)

    • vams
    • volumetric
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  10. 2026

    Volumetric absorptive microsampling showed better precision than dried blood spots and a metabolic profile closer to whole blood, with stable signalling lipids for 24 hours at room temperature but significant changes after one week unless stabilised, indicating feasibility for decentralised sampling with the need for storage strategies.

    Volumetric absorptive microsampling for profiling of signaling lipids: a comparative analysis with whole blood and dried blood spotsThangavelu et al., Analytical and bioanalytical chemistry

    • vams
    • volumetric
    • blood
    • dbs
    • metabolome
    • dried
    • validation
    • biomarkers
  11. 2026

    This study found that volumetric absorptive microsampling shows satisfactory agreement with venous plasma for monitoring several antiseizure medications in paediatric patients. However, a blood-to-plasma conversion factor was required to estimate plasma concentrations for clobazam and carbamazepine metabolites due to poor capillary-to-plasma interchangeability.

    Volumetric Absorptive Microsampling (VAMS) for Therapeutic Drug Monitoring of Antiseizure Medications (ASMs) in Pediatric PatientsSimeoli et al., Pharmaceuticals (paywalled)

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • pediatric
    • tdm
  12. 2026

    An LC-MS/MS method for tamoxifen and six metabolites in VAMS was developed and validated, with water prerinsing improving recoveries and poor room temperature stability but stability for at least 100 days at minus 80 degrees Celsius. Plasma to blood ratios were used to estimate plasma equivalent concentrations, and paired VAMS and plasma samples from ten breast cancer patients showed strong correlations and good agreement on Bland-Altman analysis, supporting reliable decentralised TDM.

    Development and validation of an LC-MS/MS method for the comprehensive quantification of tamoxifen and its metabolites in volumetric absorptive microsampling: clinical application in breast cancer patientsKuo et al., Analytical and bioanalytical chemistry (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • oncology
  13. 2026

    VAMS gave near‑quantitative recovery for cadmium and lead in human blood and correlated strongly with venous sampling, with pre‑cleaning improving correlation and lowering background lead, supporting its use for decentralised biomonitoring of these toxic elements.

    Application of volumetric absorptive microsampling (VAMS) for the simultaneous determination of cadmium and lead in bloodGutknecht et al., Environmental monitoring and assessment (paywalled)

    • vams
    • venous-agreement
    • blood
    • dried
    • toxicology
    • validation
  14. 2026

    In 480 adults, capillary specimens from fingertip lancets or the TAP Micro Select device gave clinically comparable results to venous samples for 16 of 18 routine chemistry analytes; potassium and chloride were not interchangeable, and fingertip collection showed more haemolysis, both points to weigh before decentralised microsampling of routine chemistry.

    Venous-capillary blood agreement for routine chemistry analytes: effects of collection site and sample matrixDeza et al., Clinical chemistry and laboratory medicine (paywalled)

    • venous-agreement
    • blood
    • capillary
    • yourbio
    • validation
  15. 2026

    This method validation for 15 cardiovascular drugs found that VAMS and Capitainer-B provided interchangeable patient results, although Capitainer-B showed higher matrix effects while VAMS exhibited stability losses for specific analytes after two weeks. The work confirms the suitability of these microsampling workflows for decentralised adherence monitoring but highlights the need for analyte-specific stability testing.

    Capillary blood microsampling and LC-Orbitrap analysis for adherence monitoring of cardiovascular drugs: method development, cross-validation, and patient proof-of-concept using VAMS and Capitainer-BKretschmer et al., Talanta (paywalled)

    • vams
    • volumetric
    • blood
    • tdm
    • dried
    • capillary
    • validation
  16. 2026

    A liquid chromatography-tandem mass spectrometry method was successfully validated for measuring androstenedione, 17α-hydroxyprogesterone, and 11-ketotestosterone in dried blood samples collected via volumetric absorptive microsampling. The dried samples remained stable at room temperature for up to a week and after postal transit, and plasma concentrations could be reliably estimated from the microsamples when adjusting for haematocrit.

    Analytical validation of a dried blood microsampling method to measure androstenedione, 17α‑hydroxyprogesterone, and 11‑ketotestosterone for congenital adrenal hyperplasia monitoringDe Baets et al., Talanta (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • pediatric
    • hormones
    • haematocrit
  17. 2026

    Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.

    Clinical validation of a DBS-based LC-MS/MS method for 25-hydroxyvitamin D: from lab sampling to home samplingHeughebaert et al., Clinical chemistry and laboratory medicine (paywalled)

    • venous-agreement
    • blood
    • dbs
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
    • biomarkers
  18. 2026

    Vaginal self-sampling achieved higher pooled sensitivity and specificity than urine self-sampling for detecting high-risk HPV, making it the preferred option, while urine self-sampling remains a useful non-invasive choice for under-screened populations.

    Diagnostic Accuracy of Urine and Vaginal Self-Sampling for Detection of High-Risk Human Papillomavirus: A Systematic Review and Meta-AnalysisRakhat & Aimagambetova, Viruses

    • first-void
    • sti
    • self-collection
    • hpv
    • urine
    • validation
  19. 2026

    For decentralised testing, a study found dry vaginal self-samples using Copan FLOQSwabs stored up to two weeks at room temperature maintain DNA quality. However, first-void urine collected with the Colli-Pee device may be less sensitive for HPV detection, showing lower positivity and higher cycle threshold values, median Ct 30 versus 27 for other samples.

    Evaluation of the Quality and Suitability of Self-Collected Vaginal and Urine Samples for Human Papillomavirus Testing: A Prospective Matched StudyChu et al., BJOG : an international journal of obstetrics and gynaecology

    • colli-pee
    • first-void
    • sti
    • self-collection
    • dried
    • hpv
    • urine
    • validation
  20. 2026

    A prospective study of eleven adults with epilepsy found that saliva microsampling using VAMS showed excellent agreement with conventional liquid saliva for perampanel quantification, with a mean bias of -0.126 ng/mL. This supports analytical equivalence for decentralised monitoring, though the small sample size limits generalisability.

    Clinical validation of a patient-friendly saliva microsampling approach to monitor perampanel levels in people with epilepsyFranco et al., Epilepsia (paywalled)

    • vams
    • neoteryx-mitra
    • tdm
    • validation
    • saliva
  21. 2026

    An optimised VAMS workflow for blood proteomics increased protein identifications 4-fold in plasma and 2.1-fold in whole blood compared with liquid processing, with mean CVs below 11%, and whole blood showed greater robustness and storage stability at room temperature for up to 14 days. This enables reliable patient-centric microsampling for longitudinal biomarker studies.

    Advancing Blood Proteome Analysis Past the Plasma Age: Mass Spectrometry of Whole Blood and Plasma Collected with Volumetric Absorptive Microsampling DevicesKarsten et al., Journal of proteome research (paywalled)

    • vams
    • neoteryx-mitra
    • blood
    • dried
    • validation
    • biomarkers
  22. 2026

    Self-sampling for HPV testing using urine and swab devices achieved high DNA detection rates, 92.1-99.7%, and very high participant acceptance, 99.1%, in a primary care population, supporting decentralised screening in low-resource settings.

    Population-based self-sampling under primary care conditions - a possible approach for cervical cancer screening in Indonesia (IndoCerCa study)Wenang et al., Reproductive health

    • urine
    • self-collection
    • validation
    • acceptability
    • hpv
    • sti
  23. 2026

    Midstream urine self-collection demonstrated adequate sensitivity for Chlamydia trachomatis screening in asymptomatic patients, although it was less sensitive than vaginal swabs in women, and the study confirmed that nucleic acids in neat urine remain stable for up to seven days when stored at 4°C.

    The potential use of midstream urine samples for diagnosing Chlamydia/Gonorrhoea NAAT in male and female patients, and the pre-analytical storage conditions in neat urine specimensIlardo et al., The new microbiologica (paywalled)

    • sti
    • self-collection
    • liquid
    • urine
    • validation
  24. 2026

    This study found strong agreement between self-collected urine samples tested with the INDICAID HPV assay and clinician-collected swabs tested with the BD Onclarity assay for detecting high-risk HPV. The results suggest that urine-based self-collection offers a reliable alternative for cervical cancer screening, potentially improving access for women who face barriers to standard care.

    Agreement between INDICAID™ HPV (human papillomavirus) Urine Test and BD Onclarity™ HPV Assay in detection of high-risk HPV in self-collected urine samplesYung et al., Journal of gynecologic oncology (paywalled)

    • sti
    • self-collection
    • hpv
    • liquid
    • urine
    • validation
  25. 2026

    This meta-analysis found that urine self-sampling for HPV detection had significantly lower sensitivity for high-grade lesions compared to vaginal and cervical samples, though specificity remained comparable. Despite the reduced diagnostic accuracy, the non-invasive and acceptable nature of urine sampling supports its use as a decentralised option to improve screening uptake.

    A systematic review and meta-analysis of diagnostic accuracy of urine self-sampling for human papillomavirus detection in cervical cancer screeningNath et al., Journal of medical screening (paywalled)

    • acceptability
    • sti
    • self-collection
    • hpv
    • urine
    • validation
  26. 2026

    Genital swabs demonstrated a significantly higher human papillomavirus positivity rate than self-collected urine samples or urethral swabs in men, suggesting that urine may be a less sensitive matrix for screening in this population.

    Urine sample for HPV detection in men: is it a valid and non-invasive diagnostic alternative?Sucato et al., Microbiology spectrum

    • sti
    • self-collection
    • hpv
    • urine
    • validation
  27. 2026

    This study found that self-collected vaginal dry swabs provided noninferior sensitivity for detecting high-grade cervical lesions compared to practitioner-collected samples, although specificity was lower.

    Clinical Validation of the Roche cobas and cobas 4800 Human Papillomavirus Tests on Self-Collected Vaginal Dry Swabs versus Practitioner-Collected Cervical Specimens Using the VALHUDES ProtocolHawkes et al., The Journal of molecular diagnostics : JMD (paywalled)

    • sti
    • self-collection
    • dried
    • hpv
    • validation
  28. 2026

    Dried urine strips demonstrated high diagnostic accuracy and stability for chlamydia and gonorrhea detection compared to standard urine samples. This method supports decentralised screening by allowing self-collection and ambient temperature transport without compromising sample integrity.

    Development and evaluation of dried urine strip for genital chlamydia and gonorrhea testingGibbons et al., Journal of clinical microbiology

    • sti
    • self-collection
    • dried
    • urine
    • validation
    • genotyping
  29. 2026

    Single unstimulated whole saliva measurements show high physiological variability, but averaging repeated self-collected samples, particularly in the evening, improves diagnostic reliability. This validation supports the implementation of home-based saliva testing for salivary gland dysfunction.

    Repeated Unstimulated Whole Saliva Collection: A Reliable Approach to Improve Diagnostic AccuracyMusella et al., Journal of oral rehabilitation

    • saliva
    • liquid
    • self-collection
    • validation
  30. 2026

    This study validated a low-cost 3D-printed smartphone attachment and paper sensor for measuring glucose, uric acid and cholesterol in saliva, demonstrating high correlation with standard ELISA results in a small clinical cohort. The authors suggest this platform offers a scalable solution for decentralised diabetes management by balancing sensitivity with affordability.

    Nanostructured zinc-coordination supraparticles on cellulose fibers: A 3D-Printed μ-FAD integrated smartphone platform for multiplexed salivary metabolic monitoringYang et al., Biosensors & bioelectronics (paywalled)

    • dct
    • economics
    • metabolome
    • self-collection
    • liquid
    • validation
    • saliva
  31. 2026

    Using a synthetic swab for saliva collection gave results closest to no swab for both resting and stimulated samples, indicating minimal pre-analytical interference. The widest metabolite coverage was achieved with ACN:MeOH at 1:1 v/v and a ZIC-HILIC column for polar metabolites plus a C18 column for non-polar metabolites, and resting versus stimulated saliva yielded distinct metabolic profiles that may provide complementary clinical insights.

    Impact of Selected Pre-Analytical and Analytical Factors on Untargeted Salivary MetabolomicsMichorowska et al., International journal of molecular sciences

    • metabolome
    • self-collection
    • liquid
    • validation
    • saliva
  32. 2026

    The study found that self-collected dried saliva on FishburneTabs achieved 92% accuracy for viral RNA detection compared to standard liquid saliva samples. This method supports decentralised testing by enabling reliable sample storage and transport for upper respiratory infections.

    Validation of Dried Saliva for Molecular DiagnosticsMora et al., ACS measurement science au

    • self-collection
    • dried
    • serology
    • validation
    • saliva
  33. 2026

    This study found that salivary 11-dehydrodexamethasone correlates strongly with serum dexamethasone, unlike salivary dexamethasone which shows poor agreement. This validation suggests patients could self-collect saliva samples at home to verify dexamethasone absorption for the overnight suppression test.

    The Utility of Salivary 11-Dehydrodexamethasone as a Marker of Dexamethasone AbsorptionMarshall et al., The Journal of clinical endocrinology and metabolism (paywalled)

    • venous-agreement
    • tdm
    • cortisol
    • self-collection
    • hormones
    • liquid
    • validation
    • saliva
  34. 2026

    This study validated a lateral flow fluorescence assay using quantum dots for saliva and europium nanoparticles for serum to detect cortisol within physiological ranges. The test operates in 15 minutes with a handheld reader, supporting point-of-care and at-home monitoring without a cold chain.

    Ultrasensitive de novo Protein Sandwich Lateral flow Fluorescence Assay for Cortisol in Saliva and Serum using Quantum dots and Europium NanoparticlesBruno et al., Journal of fluorescence (paywalled)

    • blood
    • saliva
    • liquid
    • self-collection
    • validation
    • hormones
    • cortisol
  35. 2026

    The homeRNA capillary blood collection and stabilization platform successfully captured lipopolysaccharide-induced inflammatory gene expression profiles. These transcriptomic responses were comparable to those obtained from traditional venous blood samples stabilized with RNAlater or PAXgene, demonstrating the platform's suitability for remote transcriptomic monitoring.

    From Home to Transcriptome: Comparing the Transcriptomic Profile of Induced Immune Response via Lipopolysaccharide Stimulation in homeRNA and Venous BloodBrown et al., Analytical chemistry (paywalled)

    • venous-agreement
    • stabilised
    • blood
    • capillary
    • liquid
    • validation
    • biomarkers
  36. 2026

    The study validated a semi-quantitative protocol for Epstein-Barr virus serology using dried blood spots, demonstrating 98.8% sensitivity and 96.5% specificity compared to paired venous serum samples. The successful validation in a self-sampling cohort confirms the suitability of this patient-centric microsampling approach for large-scale seroprevalence studies and decentralised trials.

    A dried blood spot protocol for high-throughput semi-quantitative analysis of Epstein-Barr Virus VCA IgG and EBNA IgG serologies based on the Roche Elecsys systemRubio-Acero et al., Virology journal

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  37. 2026

    In pregnant women at high risk of gestational diabetes, the GTT@home capillary glucose device showed a small positive bias of 0.16 mmol/L versus venous laboratory OGTT, with 79.8 per cent of results in the lowest surveillance risk zone and diagnostic classification agreement in 54 of 61 cases, suggesting it could support home OGTT in pregnancy.

    Use of the GTT@home Oral Glucose Tolerance Test Kit in Gestational Diabetes Mellitus: Performance Evaluation StudyDunseath et al., JMIR diabetes

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
  38. 2026

    A machine learning model called Remote Control was trained on 2685 blood samples to predict change due to instability, enabling accurate calibration of results to approximate the time zero value at collection. With calibration, unprocessed whole blood could be transported for up to 9 days under ambient conditions and temperatures between 3.4 and 47.4 degrees Celsius, achieving agreement with CLIA TEa between 98.1 and 100 per cent and expanding the catalog of tests available for at-home collection.

    Prolonging Sample Stability with Machine Learning Expands the Catalog of Tests Available for Mail-In Capillary Blood Collected At-HomeO'Meara et al., Analytical chemistry (paywalled)

    • dct
    • blood
    • self-collection
    • capillary
    • liquid
    • validation
    • biomarkers
  39. 2026

    The True Dose TD-EPI kit demonstrated strong analytical agreement with venous blood for epirubicin monitoring, and the capillary samples remained stable for 72 hours at ambient temperature.

    Method-Comparison Validation of a Novel Capillary Blood Collection Kit, True Dose<sup>®</sup> TD-EPI, for Therapeutic Drug Monitoring of EpirubicinDe Chiara et al., Pharmaceuticals

    • venous-agreement
    • stabilised
    • blood
    • tdm
    • oncology
    • capillary
    • liquid
    • validation
  40. 2026

    This UK consensus opinion outlines how clinical laboratories can validate self-collected capillary blood sampling against venous reference standards to achieve accreditation and facilitate the shift towards community-based patient care.

    UK recommendations for the validation and adoption of capillary blood testing within the routine clinical laboratory: Consensus opinion from the LabMed patient-centred testing and sampling (PaCTS) groupWoolley et al., Annals of clinical biochemistry (paywalled)

    • venous-agreement
    • blood
    • standards
    • self-collection
    • capillary
    • liquid
    • validation
  41. 2026

    Capillary blood samples collected by staff or self-collected by participants showed strong correlation and clinically acceptable agreement with venipuncture for influenza haemagglutination inhibition titers. The small differences observed were not clinically meaningful, and adequate sample volume was achieved in most attempts, supporting the feasibility of decentralised serological testing.

    Comparison of influenza hemagglutination inhibition titers from capillary blood versus venipunctureRick et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology (paywalled)

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • serology
  42. 2026

    Self-collected capillary blood samples posted by standard mail showed high concordance with couriered venous samples for HbA1c, creatinine and lipid parameters, supporting their use for remote monitoring in diabetes management and screening.

    Concordance of HbA1c, creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and self-collected capillary blood samples sent by mailHoffmeister et al., Journal of diabetes investigation

    • venous-agreement
    • blood
    • self-collection
    • capillary
    • liquid
    • validation
  43. 2026

    This study found that measuring thyroid-stimulating hormone via dried blood spots and a volumetric device showed high agreement with serum results, with classification accuracy exceeding 96 per cent. The volumetric approach demonstrated improved reproducibility and stability, supporting its use for decentralised thyroid function monitoring.

    Adaptation of a routine immunoassay analyser for TSH measurement in dried blood spot and volumetric microsampling (Capitainer B50): evaluation for thyroid function testing in adultsBornikowska et al., Practical laboratory medicine

    • blood
    • dried
    • dbs
    • volumetric
    • validation
    • venous-agreement
    • hormones
  44. 2026

    This study validated a dried blood spot method for tacrolimus monitoring and demonstrated agreement with venous whole blood measurements in kidney transplant recipients. It also found that dried blood spot analysis of the biomarker CXCL-10 was elevated in patients experiencing rejection or infection, supporting its use for decentralised monitoring.

    Dried Blood Spot for CXCL-10 and Tacrolimus: Integrated Non-Invasive Monitoring to Guide Personalized Treatment in Adult Kidney Transplant RecipientsMillán et al., Pharmaceuticals

    • venous-agreement
    • blood
    • dbs
    • tdm
    • dried
    • immunosuppressants
    • validation
    • biomarkers
  45. 2026

    Self-collected dried blood spot specimens for phenylketonuria monitoring showed very poor quality initially but improved substantially over a decade with training and education, reducing measurement error and the risk of incorrect clinical interpretation.

    Improving self-collected dried blood spot specimens for phenylketonuria monitoring: a 10-year computer vision review of dried blood spot specimen qualityFlynn et al., Clinica chimica acta; international journal of clinical chemistry (paywalled)

    • blood
    • dbs
    • self-collection
    • dried
    • validation
  46. 2026

    Although most kidney transplant recipients successfully collected capillary blood samples at home, haemolysis and transport conditions affected analyte stability. Agreement with venous sampling was acceptable for haemoglobin and creatinine, but potassium and haematocrit exceeded total allowable error limits.

    At-home blood collection for clinical chemistry analyses in a kidney transplant population: a feasibility studyHoekstra et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • self-collection
    • validation
    • venous-agreement
  47. 2026

    This developer study reports that a self-collection kit interfacing with a BD Microtainer produced RNA of sufficient quality and yield for transcriptomic analysis in a pilot group and a longitudinal rheumatology cohort. Most participants found the device easy to use, supporting its utility for decentralised blood sampling.

    To the homeRNAmax: Developing an Improved Blood Self-Collection and Stabilization Platform for Remote Transcriptomic StudiesEakman et al., Analytical chemistry (paywalled)

    • dct
    • blood
    • self-collection
    • bd-microtainer
    • liquid
    • validation
    • biomarkers
  48. 2026

    This study employed volumetric absorptive microsampling to collect blood samples from neonates, revealing that existing propofol pharmacokinetic models poorly predicted drug levels in this population. A newly developed meta-model provided accurate predictions, validating the use of patient-centric microsampling for therapeutic drug monitoring in preterm and term infants.

    Systematic evaluation of propofol population pharmacokinetic models and development of a literature-supported new meta-model for critically ill preterm and term neonatesRantanen et al., European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • pediatric
    • tdm
  49. 2026

    This study validated a method for monitoring mycophenolic acid in paediatric patients, demonstrating that quantitative dried plasma spots achieved close agreement with venous plasma. Quantitative dried blood spots showed significant haematocrit-related bias, making the plasma-based format more suitable for decentralised monitoring.

    Matrix fidelity in microsampling: Plasma-first LC-MS/MS quantification of mycophenolic acid and MPAGKocur et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • venous-agreement
    • blood
    • qdbs
    • tdm
    • haematocrit
    • dried
    • pediatric
    • immunosuppressants
    • validation
  50. 2026

    Capillary samples collected using dried blood spots and Mitra microsamplers showed strong agreement with venous plasma for quantifying IgG antibodies against most vaccine-preventable diseases. Sensitivity was high for the majority of pathogens, though the study noted that antibody stability declined at room temperature over time, favouring cold storage for longer durations.

    Comparison of capillary microsampling and venous blood for multi-pathogen serosurveillanceOmbati et al., Scientific reports (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
    • serology
  51. 2026

    Task sharing dried blood spot collection for HIV viral load testing with community lay cadres achieved high diagnostic agreement with healthcare worker collections and was highly acceptable to patients. This approach offers a viable strategy to overcome healthcare worker shortages and support decentralised viral load monitoring in resource-limited settings.

    Feasibility and acceptability of task sharing collection of HIV viral load dried blood spot samples with community lay cadres: A cross-sectional diagnostic validation study in ZimbabwePrust et al., PLOS global public health

    • acceptability
    • blood
    • dbs
    • dried
    • serology
    • validation
  52. 2026

    This review establishes that microsampling across blood, saliva, urine and stool matrices offers validated workflows and regulatory recognition for human biomonitoring comparable to conventional methods. It finds that these decentralised approaches enhance participant acceptability and enable screening in remote or low-resource settings.

    Integrating Microsampling in Human Biomonitoring: Methodologies, Regulatory Frameworks, and Case Study InsightsRajamani & Poongavanam, Critical reviews in analytical chemistry (paywalled)

    • wearable
    • acceptability
    • multimodal
    • sweat
    • blood
    • dbs
    • standards
    • dried
    • serology
    • colorectal
    • pediatric
    • stool
    • urine
    • validation
    • saliva
    • biomarkers
  53. 2026

    Volumetric microsampling can enable patient-centred therapeutic drug monitoring with high patient preference and acceptable method validation for many drugs, but conversion from capillary to plasma and agreement with venous sampling varies by analyte and requires careful validation.

    Volumetric Microsampling for Patient-Centric Therapeutic Drug Monitoring in Clinical Pharmacology: A Scoping ReviewTummala et al., Journal of clinical pharmacology (paywalled)

    • volumetric
    • venous-agreement
    • acceptability
    • blood
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  54. 2026

    Capillary fingerstick sampling showed high correlation and agreement with venous sampling for serum AMH but with proportional bias, so it may improve access to testing yet should not be considered fully interchangeable without further validation.

    Comparison of serum anti-Müllerian hormone concentrations measured in capillary fingerstick and venous samples from Korean reproductive-aged womenLavadia et al., Clinical and experimental reproductive medicine (paywalled)

    • blood
    • capillary
    • validation
    • venous-agreement
    • acceptability
    • fertility
    • hormones
  55. 2026

    Fingerstick capillary sampling showed strong agreement with venous sampling for mycophenolic acid, tacrolimus and cyclosporine A, with acceptable bias and improved agreement for mycophenolic acid after haematocrit correction. This minimally invasive approach may reduce procedural burden and support outpatient or home based therapeutic drug monitoring in children.

    Minimally Invasive Therapeutic Drug Monitoring of Immunosuppressants in Children with Kidney Diseases: Validation of Fingerstick Sampling Using LC-MS/MSIshii et al., Pharmaceuticals

    • venous-agreement
    • blood
    • tdm
    • haematocrit
    • capillary
    • pediatric
    • immunosuppressants
    • validation
  56. 2026

    This study validated a method requiring only 10 microlitres of serum and found high agreement between fingerstick capillary samples and venous serum for monitoring twelve antibiotics. The results suggest capillary serum sampling is a feasible, minimally invasive alternative that avoids the haematocrit effect associated with whole blood microsampling.

    Feasibility verification of fingerstick capillary microsampling replacing venipuncture for therapeutic drug monitoring of 12 antibiotics using a rapid LC-MS/MS assayChen et al., Talanta (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
    • pediatric
    • tdm
    • antimicrobials
  57. 2026

    The study developed and validated a reliable HPLC-MS method for quantifying multiple tyrosine kinase inhibitors from VAMS microsamples of capillary blood, showing acceptable accuracy, precision, and 28-day stability at -21°C, with results comparable to venous plasma in 194 samples from patients with solid tumours. This enables therapeutic drug monitoring using microsamples in oncology practice.

    HPLC-MS Quantification of Multiple Tyrosine Kinase Inhibitors in Patients with Solid Tumors: Method Validation and Clinical ApplicationStaudinger et al., Pharmaceutics (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • oncology
  58. 2026

    A validated two-step LC-MS/MS protocol can identify 91 prohibited doping agents from a single dried blood spot collected on either cellulose cards or volumetric absorptive microsampling devices. This demonstrates robust multi-analyte screening from capillary blood, supporting decentralised anti-doping programmes where venous sampling is impractical.

    Dried Blood Spots for Doping Purpose-Two-Step Protocol for Analysis of Non-Threshold Substances and Anabolic Steroid Esters From One Spot/PebbleStojanovic et al., Biomedical chromatography : BMC (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • validation
    • doping
    • toxicology
  59. 2026

    Capillary finger-stick dried blood spots demonstrated strong analytical agreement with venous serum for prostate-specific antigen (R² = 0.987) and remained stable for 31 days across a wide temperature range. This less invasive microsampling approach enables at-home self-collection, supporting decentralised screening and tele-diagnostics for prostate cancer.

    Accessible Prostate-Specific Antigen Testing through Finger-Stick Dried Blood Spots and Routine Laboratory Analyzersvan Vugt et al., The journal of applied laboratory medicine (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • haematocrit
    • biomarkers
  60. 2026

    This review highlights that microsampling techniques such as dried blood spots and volumetric absorptive microsampling offer superior alternatives to traditional sampling for the mass spectrometry detection of prohibited substances in anti-doping analysis. It provides guidance on selecting appropriate analytical methods and sample pretreatment strategies to ensure sensitive detection and reliable storage conditions.

    Mass Spectrometry-Based Anti-Doping Analysis: A Critical Review of Emerging Analytical and Sample Pretreatment StrategiesMaykar et al., Critical reviews in analytical chemistry (paywalled)

    • blood
    • urine
    • dried
    • vams
    • dbs
    • validation
    • doping
    • toxicology
  61. 2026

    The dried urine spot device showed strong agreement with liquid urine across three clinical chemistry analysers and stable performance across temperatures, enabling decentralised ambient collection for albumin-to-creatinine ratio.

    Analysis of albumin-to-creatinine ratio on automated analysers using a microsampling card (Capitainer DIP70 card) for the collection of urineOlausson et al., Clinical chemistry and laboratory medicine (paywalled)

    • urine
    • dried
    • validation
  62. 2026

    Capillary blood collected with Tasso+ devices demonstrated strong agreement with venous blood for primary Athlete Biological Passport markers (haemoglobin, reticulocytes, OFF-score, ABPS) with correlations ≥0.9, though platelet count showed poor concordance. Despite 44 of 209 samples failing pre-analytical checks mainly due to coagulation, high athlete acceptance and minimal pain support capillary sampling as a less invasive, viable alternative for decentralised anti-doping controls.

    Capillary Blood as a Potential New Matrix for the Athlete Biological Passport: A Field-Based Comparison StudyRequena-Tutusaus et al., Medicine and science in sports and exercise (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
    • acceptability
    • doping
  63. 2026

    ALAS2 and CA1 mRNA were reliably quantified from venous-cellulose, capillary-cellulose and Tasso-M20 dried blood spots with strong linear agreement (r ≥ 0.96) and no bias for ALAS2. CA1 showed modest proportional bias of 9-22% only when Tasso-M20 was compared with cellulose cards in the rEPO cohort, but no significant differences in relative expression across matrices were observed at any timepoint. These findings support decentralised capillary sampling for longitudinal anti-doping monitoring.

    Comparison of Dried Blood Spot Sampling Methods for RNA-Based Biomarker Measurement in Anti-DopingBejder et al., Drug testing and analysis

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • doping
    • biomarkers
  64. 2026

    In a cohort of 62 participants evaluating home self-collection with the TassoPlus device, 38 returned samples, with 29% excluded due to insufficient plasma volume below 200 ΔL. Although viral load measurements in adequate samples correlated well with conventional testing (r = 0.800), the high failure rate and missed detection in low-volume viremic samples indicate that further technical refinements are necessary before clinical adoption.

    Feasibility and reliability of decentralized HIV-1 viral load monitoring on self-sampled bloodMendes de Leon et al., PloS one

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • serology
  65. 2026

    Saliva and dried saliva spot lamotrigine concentrations correlated strongly with plasma (R approximately 0.84 to 0.85), supporting saliva and DSS as needle-free alternatives for therapeutic drug monitoring.

    Toward needle-free lamotrigine monitoring: Proof-of-concept for saliva and dried saliva spot analysis by LC-MS/MS - a short communicationĎurčová et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • saliva
    • dried
    • validation
    • venous-agreement
    • tdm
  66. 2026

    Low-volume blood collection devices enable frequent, longitudinal sampling at home with reduced invasiveness, thereby improving participant retention in patient-centric studies. This facilitates decentralised biomarker monitoring for tracking disease progression and understanding physiological responses to diet, medication and physical activity.

    Low-volume collection devices for longitudinal biomarker monitoring in patient-centric sampling settingsSimon-Guth et al., Bioanalysis (paywalled)

    • blood
    • self-collection
    • validation
    • dct
    • biomarkers
  67. 2026

    A liquid-phase microsampling method using 2.8 µL of whole blood demonstrated strong correlation with conventional venous sampling for immunosuppressant monitoring in renal transplant recipients. This approach enables patient-centric therapeutic drug monitoring, reducing burden and supporting implementation in home-based, paediatric, and telemedicine settings.

    Clinical Application of Microvolume LC-MS/MS for Therapeutic Drug Monitoring of Immunosuppressants in Solid-Organ Transplant RecipientsIwami et al., Journal of clinical medicine

    • blood
    • liquid
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit
  68. 2026

    The authors validated VAMS for lumateperone therapeutic drug monitoring and confirmed its stability, which supports decentralised, patient-centric antipsychotic therapy through low-volume blood collection.

    Volumetric absorptive microsampling for lumateperone analysis: method validation and stability evaluationMilandri et al., Analytical and bioanalytical chemistry

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm
  69. 2026

    The authors developed and optimised a dual LC-MS workflow for non-targeted metabolomics from blood microsamples, comprising a 15-minute HILIC-MS method for polar metabolites and an RPLC-MS method for mid- to non-polar compounds. A 20% water/80% methanol extraction with rehydration offered a practical compromise that detected numerous metabolite features across amino acid, acylcarnitine and bile acid pathways, enabling decentralised metabolomic analysis.

    RPLC- and HILIC-based non-targeted metabolomics workflow for blood microsamplesCouacault & Witting, Metabolomics : Official journal of the Metabolomic Society

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • metabolome
  70. 2026

    Salivary HPV DNA testing achieved 91.7% sensitivity and 100% specificity against oropharyngeal swab in patients with oral cavity cancer, demonstrating potential for non-invasive self-collection screening programmes and long-term monitoring of HPV-driven disease.

    Application of a Saliva-Based Liquid Biopsy for the Detection of HPV in Patients With Oral Cavity Squamous Cell Carcinoma (OCSCC)Bulfoni et al., Head & neck

    • saliva
    • self-collection
    • validation
    • hpv
    • liquid-biopsy
  71. 2026

    The Phase HPV Urine Test detected 14 high-risk HPV types from first-void urine samples, showing 93 per cent concordance with the Roche cobas 4800 reference assay after sequencing adjudication. The test demonstrated high precision, a low limit of detection, and ten-day stability at ambient temperature, supporting non-invasive, self-collected screening to improve access and participation.

    Performance of a novel, urine-based test for the detection of cervical human papillomavirus infectionManjeshwar et al., Journal of clinical microbiology

    • urine
    • first-void
    • self-collection
    • validation
    • hpv
    • sti
  72. 2026

    The Alinity m STI assay achieved strong agreement with comparator nucleic acid amplification tests across female urogenital specimens, with κ scores of 0.84 to 0.99. Urine and self-collected vaginal swabs showed high positive agreement (≥99.2% and ≥98.0% respectively), validating their reliability for decentralized STI screening.

    Evaluation of Alinity m STI Assay for Simultaneous Detection of Chlamydia trachomatis , Neisseria gonorrhoeae , Trichomonas vaginalis , and Mycoplasma genitalium in Female Urogenital SpecimensGentil et al., Sexually transmitted diseases

    • urine
    • self-collection
    • validation
    • sti
  73. 2026

    In a multicentre European study the Papilloplex HR-HPV assay showed similar clinical sensitivity for CIN2+ on self collected urine and vaginal swabs compared with clinician taken cervical samples, while clinical specificity was similar for urine but lower for vaginal swabs; cut off optimisation restored specificity for vaginal swabs without compromising sensitivity.

    Clinical performance assessment of the Papilloplex HR-HPV assay on self-taken urine and vaginal swab samples: findings from a multicentre European studyCuschieri et al., Journal of clinical pathology (paywalled)

    • urine
    • self-collection
    • validation
    • hpv
    • sti
  74. 2026

    Capillary whole blood collected and dried on the OneDraw device gave robust PFAS measurements with low limits of quantification, and levels of ten PFAS correlated strongly with matched venous plasma levels in 133 veterans, enabling remote sampling without clinical infrastructure.

    Use of a capillary blood collection device to monitor exposure to per- and polyfluoroalkyl substances (PFAS) in Veterans living in proximity to potential sources of environmental contaminationHavens et al., Journal of exposure science & environmental epidemiology (paywalled)

    • blood
    • dried
    • capillary
    • validation
    • venous-agreement
  75. 2026

    Capillary blood obtained using an at-home collection device matched venous blood closely in immune cell composition and phenotype. Although shipping affected myeloid cells, T cell numbers, subsets, and phenotypes stayed stable, which supports the practicality of remote immune monitoring.

    An at-home blood collection device for remote immune monitoring by high-parameter flow cytometryKonecny et al., JCI insight

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
  76. 2026

    Self-collected dried blood spots from 40 healthy participants arrived intact and yielded good-quality DNA, with most immune and epigenetic biomarkers remaining stable for up to six weeks at room temperature. The study confirms that minimally invasive dried blood and plasma spot sampling is feasible for scalable, longitudinal biomolecular surveillance in occupational health settings.

    Dried blood spot-based monitoring of immune and epigenetic biomarkers in occupational exposure studiesDe Ryck et al., Journal of exposure science & environmental epidemiology (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • acceptability
    • biomarkers
  77. 2026

    Finger-stick dried blood spots produce creatinine measurements that correlate strongly with venous plasma (R² = 0.97), with 91% sensitivity and 96% specificity for detecting reduced eGFR. Creatinine stays stable in dried spots for up to one month at refrigerated or frozen temperatures, supporting accurate home-based kidney function screening, patient follow-up, and medication management.

    Creatinine measurement from finger stick dried blood spots with a routine chemistry analyzer for estimation of GFRvan Dam et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • haematocrit
  78. 2026

    This scoping review identified 15 distinct technologies for measuring HbA1c from capillary blood, with point-of-care devices requiring only 2 to 10 µL and delivering results within minutes. However, diagnostic accuracy varied widely between studies and devices, and most evidence comes from high-income countries, indicating gaps in validation for low- and middle-income settings where decentralised screening is most needed.

    HbA1c measurement using capillary blood in epidemiological studies: a scoping review of technologies and approachesBreternitz et al., BMC endocrine disorders (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
  79. 2026

    Home DBS sampling gave testosterone results that agreed well with venous blood in men on intramuscular testosterone undecanoate, but showed falsely high values in those using topical gel, likely from skin contamination. Patients preferred home collection for its convenience, suggesting DBS is viable for decentralised monitoring of injectable testosterone if patients are taught proper technique.

    From venipuncture to self-sampling dried blood spots: a shift in monitoring testosterone levelsOlthof et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • fertility
    • hormones
    • tdm
  80. 2026

    The TaqPath kit performed well for HIV drug resistance testing from dried blood spots in samples with high viral loads, meeting WHO criteria for sensitivity and mutation detection, but showed reduced sensitivity at lower viral loads below 5000 copies/mL. This supports the use of DBS for decentralised HIV monitoring in resource-limited settings, though caution is needed when viral load is low.

    Evaluation of the Applied Biosystems™ TaqPath™ Seq HIV-1 Genotyping Kit for HIV-1 drug resistance testing from dried blood spot specimensOkafor et al., Journal of virological methods (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • serology
  81. 2026

    The lateral flow assay showed 80.6% sensitivity and 94.2% specificity in first-void urine from asymptomatic men, and 81.8% sensitivity and 98.1% specificity in vaginal swabs from asymptomatic women. Vaginal swab performance met WHO screening criteria for low-resource settings, while urine specificity fell short, indicating the assay is suitable for decentralised STI screening in women but needs improvement for men.

    Cross-sectional evaluation of a lateral flow assay for point-of-care detection of <i>Neisseria gonorrhoeae</i> in asymptomatic individuals at primary healthcare facilities in South AfricaPeters et al., Sexually transmitted infections (paywalled)

    • urine
    • first-void
    • validation
    • sti
  82. 2026

    The fluorescence-enhanced catalytic hairpin assembly nanobiosensor detected HPV16 E7 mRNA with high sensitivity and specificity in first-void urine, showing linear performance across clinically relevant concentrations and stability for 45 days, offering a promising tool for decentralised HPV screening programmes.

    Fluorescence-Enhanced Catalytic Hairpin Assembly-Driven Nanobiosensor for Ultrasensitive Detection of HPV16 E7 mRNABina et al., Journal of medical virology (paywalled)

    • urine
    • first-void
    • validation
    • hpv
  83. 2026

    The study validated an LC-MS/MS method for eight antiepileptic drugs and two metabolites in dried blood spot and VAMS formats, with satisfactory analytical performance and stability, and was the first to include the oxcarbazepine metabolite DHCB. In 80 paired patient samples, microsampling concentrations showed promising correlation with plasma, supporting decentralised therapeutic drug monitoring of antiepileptic treatment.

    Development and application of an LC-MS/MS method for 8 antiepileptic drugs and 2 metabolites using microsampling techniques (DBS and VAMS)Cobo-Golpe et al., Journal of analytical toxicology

    • blood
    • dried
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • haematocrit
  84. 2026

    Untargeted metabolomic profiles from three blood microsampling devices aligned more closely with whole blood than with plasma, and all devices distinguished sex based on amino acids, lipids, and acylcarnitines. This validates that device choice can be tailored to the metabolites of interest for decentralised human biomonitoring.

    An LC-MS untargeted metabolomic comparison between three blood microsampling devices, whole blood, and plasmaAvella et al., Metabolomics : Official journal of the Metabolomic Society

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • metabolome
    • biomarkers
  85. 2026

    This narrative review surveys remote biospecimen collection products for sexual health research, including dried blood spots and volumetric absorptive microsampling, and concludes that successful implementation needs a multidisciplinary, participant-centred team with sufficient time allocated to the complexities of collection procedures and processes.

    A Narrative Review of Remote Biospecimen Collection Product and Implementation Considerations for Sexual Health Clinical ResearchHorvath et al., AIDS and behavior (paywalled)

    • blood
    • dried
    • vams
    • dbs
    • self-collection
    • validation
    • dct
    • serology
    • sti
  86. 2026

    A streamlined workflow quantified up to 10,000 protein groups and post-translational modifications from 20 microlitres of dried blood collected by volumetric absorptive microsampling, with mass spectrometry acquisition under two hours. The study established stability profiles and best practices for dried blood proteomics, supporting its feasibility for decentralised precision medicine and disease phenotyping.

    Development and Validation of a Streamlined Workflow for Proteomic Analysis of Proteins and Post-translational Modifications from Dried BloodFoster et al., Journal of proteome research (paywalled)

    • blood
    • dried
    • vams
    • validation
    • biomarkers
    • multi-omics
    • multimodal
  87. 2026

    The authors validated a liquid-liquid extraction LC-MS/MS method that quantifies cannabinoids in only 50 µL of liquid whole blood with lower limits of quantitation from 0.10 to 1.0 ng/mL. This microsampling approach enables roadside collection via finger prick, allowing measurement of THC levels at the time of driving without trained phlebotomists, thus overcoming delays that reduce THC concentrations.

    Validation of a microsampling-compatible liquid-liquid extraction method for cannabinoid quantitation in 50 µL of whole blood using liquid chromatography-mass spectrometryMohammed et al., Journal of analytical toxicology

    • blood
    • liquid
    • validation
    • toxicology
  88. 2026

    The study developed and validated a rapid LC-MS/MS method for quantifying cefazolin in capillary whole blood collected via VAMS, plasma, and plasma ultrafiltrate, showing robust performance across matrices and successful application in a pediatric pilot cohort for therapeutic drug monitoring.

    Rapid, robust LC-MS/MS quantification of cefazolin in whole blood microsamples, plasma, and plasma ultrafiltrate: Analytical method validation and preliminary clinical application in pediatric populationKocur et al., Clinica chimica acta; international journal of clinical chemistry (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • pediatric
    • tdm
    • antimicrobials
  89. 2026

    This study demonstrates that a commercial conductive vial electromembrane extraction device can reliably isolate basic pharmaceuticals from whole blood collected on volumetric absorptive microsampling tips, showing superior reproducibility and reduced matrix effects compared to conventional treatment.

    Volumetric absorptive microsampling and conductive vial electromembrane extraction for the analysis of pharmaceuticals in whole bloodReguli et al., Talanta (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • haematocrit
  90. 2026

    In matched clinical samples from rheumatoid arthritis, VAMS and DBS showed strong agreement for methotrexate polyglutamates (slopes 0.95-1.07; bias within -4.21% to 0.36%; SRCC ≥ 0.969), with up to 100% of total MTXPG results within ±20% limits; capillary microsampling agreed closely with whole blood but differed from red blood cells, indicating matrix-specific differences that must be accounted for when interpreting against RBC-based reference values.

    Multi-Matrix LC-MS/MS Validation of Methotrexate Polyglutamates: Comparison of VAMS, DBS, and Conventional Blood Sampling in Rheumatoid ArthritisKocur et al., International journal of molecular sciences

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  91. 2026

    A UPLC-MS/MS method for linezolid and metabolites in oral fluid and VAMS capillary blood satisfied ICH M10 validation requirements. Linezolid concentrations correlated strongly with venous plasma in both matrices, offering a non‑invasive option for therapeutic drug monitoring, whereas metabolites were systematically underestimated in VAMS and seldom detectable in oral fluid, restricting metabolite measurement.

    Simultaneous quantification of linezolid and its metabolites (PNU-142300 and PNU-142586) in oral fluid and capillary blood by UPLC-MS/MS: method validation and clinical application using non-invasive sampling techniquesGonzález-Berdullas et al., Journal of translational medicine (paywalled)

    • blood
    • saliva
    • dried
    • capillary
    • vams
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • haematocrit
  92. 2025

    Worked case studies of patient-centric sampling deployed in pharmaceutical drug development: how sponsors have implemented it, rather than whether it is possible.

    Case Studies on the Use of Patient-centric Sampling for Clinical Studies in Pharmaceutical Drug DevelopmentPatel et al., The AAPS Journal (paywalled)

    • dct
    • venous-agreement
    • blood
    • self-collection
    • pediatric
    • validation
    • biomarkers
  93. 2025

    A head-to-head pharmacokinetic comparison of conventional venous sampling against patient-centric microsampling: exactly the bridging study regulators now expect before microsampled data supports an endpoint.

    A Pharmacokinetic Study of Zavegepant Nasal Spray in Healthy Adults Comparing Conventional Venous Blood Sampling With Patient-Centric MicrosamplingShahin et al., Clinical and Translational Science

    • dct
    • venous-agreement
    • blood
    • dried
    • capillary
    • liquid
    • validation
  94. 2025

    Patient-centric microsampling of salivary cortisol shows a 12.6 nmol/L cutoff at 60 min post cosyntropin stimulation, 89% accuracy, 85% sensitivity and 90% specificity, for adrenal insufficiency diagnosis, but reproducibility in healthy volunteers was poor.

    Utility of Salivary Cortisol and Cortisone in the Diagnostics of Adrenal InsufficiencyKvam Hellan et al., Journal of Clinical Endocrinology & Metabolism (paywalled)

    • cortisol
    • hormones
    • liquid
    • validation
    • saliva
  95. 2025

    A systematic review found mixed economic evidence for microsampling in therapeutic drug monitoring; one study reported no cost reduction with DBS home-sampling, €688 versus €676, whilst another predicted savings up to 61%. The authors caution that more work is required to assess costs alongside clinical outcomes and optimise logistics for decentralised implementation.

    The economic evidence for microsampling to support therapeutic drug monitoring: A systematic reviewCarland et al., British Journal of Clinical Pharmacology (paywalled)

    • vams
    • blood
    • economics
    • dbs
    • tdm
    • self-collection
    • dried
    • antimicrobials
    • pediatric
    • immunosuppressants
    • validation
  96. 2025

    A review of 39 studies found that dried blood spot and volumetric absorptive microsampling show promising results for therapeutic drug monitoring of oral targeted anticancer drugs. The authors state that external validation remains crucial to confirm reliability, citing haematocrit effects and sample stability as key challenges.

    Advancing Therapeutic Drug Monitoring for Oral Targeted Anticancer Drugs: From Hospital-Based Towards Home-SamplingMeertens et al., Biomedical Chromatography

    • vams
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • validation
  97. 2025

    An evaluation of blood sampling strategies across a large UK healthcare-worker cohort study, covering how sampling approach affected participation.

    Evaluating blood sampling strategies within the SIREN study: the experience from a large cohort of healthcare workers in the UKHettiarachchi et al., BMC Medical Research Methodology

    • dct
    • acceptability
    • blood
    • economics
    • self-collection
    • capillary
    • validation
  98. 2025

    A multi-targeted procedure covered 237 prohibited substances across 11 WADA classes in dried urine spots, with environmental-stability testing for refrigeration-free transport.

    LC-HRMS screening for 11 classes of prohibited substances in dried urine spots for doping controlMazzarino et al., Analytical and Bioanalytical Chemistry (paywalled)

    • neoteryx-mitra
    • doping
    • dried
    • toxicology
    • urine
    • validation
  99. 2025

    Testosterone, androstenedione, cortisol and cortisone were measurable from 200 µL saliva, but estradiol fell below quantification and progesterone in under half of samples: only a subset of steroids is reliable in saliva, and not interchangeable with serum.

    Non-invasive assessment of free steroid hormones: a high-throughput LC-MS/MS method for salivary steroid quantificationSlettvoll et al., Analytical and Bioanalytical Chemistry

    • cortisol
    • steroids
    • hormones
    • liquid
    • validation
    • saliva
  100. 2025

    Earlobe capillary microsampling of 100-250 µL found good agreement with venous draws for progesterone, concordance 0.911, and 17β-estradiol, concordance 0.919, across menstrual cycles, showing suitability for decentralised monitoring. However, participant-reported burden was not assessed, and further validation is required in elite athletes.

    Larger-volume capillary blood sampling is a valid alternative to assess progesterone and 17β-estradiol for cycle phase identificationSchlie et al., Frontiers in Physiology

    • blood
    • liquid
    • capillary
    • hormones
    • fertility
    • venous-agreement
    • validation

Read from the corpus on .