Skip to content
OpenSampling

The Library

Papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. With a free account, every entry links to a legitimate copy; nothing is copied from an abstract.

Papers 1–5 of 72 labelled “Volumetric”, newest first.

  1. 2026

    Clinical Validation of Venetoclax Volumetric Microsampling in Leukemia, with Whole-Blood-to-Plasma Conversion and Self-Microsampling Feasibility

    In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling,

    Levens et al., Clinical Pharmacokinetics (paywalled)

  2. 2026

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug Monitoring

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation.

    Huhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled)

  3. 2026

    Volumetric absorptive microsampling for profiling of signaling lipids: a comparative analysis with whole blood and dried blood spots

    Volumetric absorptive microsampling showed better precision than dried blood spots and a metabolic profile closer to whole blood,

    Thangavelu et al., Analytical and bioanalytical chemistry

  4. 2026

    Capillary blood microsampling and LC-Orbitrap analysis for adherence monitoring of cardiovascular drugs: method development, cross-validation, and patient proof-of-concept using VAMS and Capitainer-B

    This method validation for 15 cardiovascular drugs found that VAMS and Capitainer-B provided interchangeable patient results, although Capitainer-B showed higher matrix effects while VAMS exhibited stability losses for specific analytes after two weeks.

    Kretschmer et al., Talanta (paywalled)

  5. 2026

    Adaptation of a routine immunoassay analyser for TSH measurement in dried blood spot and volumetric microsampling (Capitainer B50): evaluation for thyroid function testing in adults

    This study found that measuring thyroid-stimulating hormone via dried blood spots and a volumetric device showed high agreement with serum results, with classification accuracy exceeding 96 per cent.

    Bornikowska et al., Practical laboratory medicine

Browse the whole Library with a free account

A free account opens every page of every view, search, and every finding in full with its source.

Read from the corpus on .