1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.

15 papers labelled “bd-microtainer”, newest first.

  1. 2026

    The study found that self-collection of dried blood spots and other samples using at-home kits was a useful and cost-effective method for screening a large cohort for sexually transmitted infections outside a clinic. This demonstrates the feasibility of decentralised, patient-centric sampling for population-level infectious disease surveillance.

    Prevalence of chlamydial, gonococcal and syphilis positivity by anatomical site and sex via self-collected biospecimens using at-home testing kits among a large and diverse cohort of men and women enrolled in the MACS/WIHS Combined Cohort Study (MWCCS) in the USAMimiaga et al., Sexually transmitted infections (paywalled)

    • blood
    • sti
    • dbs
    • self-collection
    • dried
    • serology
    • bd-microtainer
    • urine
  2. 2026

    Although most kidney transplant recipients successfully collected capillary blood samples at home, haemolysis and transport conditions affected analyte stability. Agreement with venous sampling was acceptable for haemoglobin and creatinine, but potassium and haematocrit exceeded total allowable error limits.

    At-home blood collection for clinical chemistry analyses in a kidney transplant population: a feasibility studyHoekstra et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • self-collection
    • validation
    • venous-agreement
  3. 2026

    This developer study reports that a self-collection kit interfacing with a BD Microtainer produced RNA of sufficient quality and yield for transcriptomic analysis in a pilot group and a longitudinal rheumatology cohort. Most participants found the device easy to use, supporting its utility for decentralised blood sampling.

    To the homeRNAmax: Developing an Improved Blood Self-Collection and Stabilization Platform for Remote Transcriptomic StudiesEakman et al., Analytical chemistry (paywalled)

    • dct
    • blood
    • self-collection
    • bd-microtainer
    • liquid
    • validation
    • biomarkers
  4. 2025

    A head-to-head of four upper-arm capillary devices, including TAP Micro Select, versus fingerstick and venous: experience and performance varied by device with none clearly superior, while analyte correlations with venous were similar across all.

    Comparing capillary blood collection technologies: patient experience, device performance and clinical accuracyCollier et al., Bioanalysis (paywalled)

    • blood
    • liquid
    • yourbio
    • capillary
    • venous-agreement
    • acceptability
    • validation
    • bd-microtainer
  5. 2025

    A vacuum-assisted upper-arm device collected a mean 538 µL and met the volume target in 85.5% of cases; 17 of 19 analytes met CLIA agreement with venous, with pain lower than fingerstick.

    Evaluation of a Simplified Upper-Arm Device for Vacuum-Assisted Collection of Capillary BloodSchaff et al., Diagnostics

    • blood
    • liquid
    • capillary
    • venous-agreement
    • acceptability
    • validation
    • bd-microtainer
  6. 2025

    A study of decentralised patient-centric microsampling found that 82% of untrained participants, 47 of 57, successfully self-collected acceptable fingerstick blood in Microtainer tubes. All 46 tested samples yielded accurate HIV viral suppression results compared to venipuncture, though this remote monitoring approach is limited to US courier services and temperature conditions.

    A cross-sectional analysis of fingerstick blood self-microcollection for remote HIV suppression monitoring in Atlanta, Georgia, USA: a path to expanding access to continuum of careJohnson et al., AIDS research and therapy

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • self-collection
    • validation
    • venous-agreement
    • serology
  7. 2025

    A prospective study of 109 subjects found that 250 μl capillary whole blood microsampling is stable for five hours in a microtainer. This patient-centric, decentralised method successfully detected most HCV genotypes at defined limits using the Xpert HCV test on the GeneXpert Xpress system and the cobas HCV platform.

    Independent assessment of a point of care HCV RNA test by laboratory analytical testing and a prospective field study in the U.SMiller et al., PloS one

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • validation
    • serology
  8. 2024

    Plasma total carbon dioxide concentrations were significantly lower in BD Microtainers compared to standard vacutainers, with reductions driven by low sample volume and transport delays rather than brief air exposure. These findings indicate that microtainers must be filled completely and analysed rapidly to maintain accuracy for this analyte.

    Impact of blood volume, air exposure duration, transport duration, and testing delay on plasma total carbon dioxide in simulated open collections using microtainersReid et al., Clinical biochemistry (paywalled)

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • validation
  9. 2024

    This study evaluated the repeatability of a point-of-care G6PD test using capillary blood collected via fingerprick and BD Microtainers, finding that modified sample application methods reduced variability in laboratory and field settings.

    Field assessment of the operating procedures of a semi-quantitative G6PD Biosensor to improve repeatability of routine testingSadhewa et al., PloS one

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • validation
  10. 2023

    TAP II capillary serum, both professionally collected and self-collected, correlated with venous serum at R > 0.9 for eight analytes including ALT, AST, cholesterol, HDL and triglycerides. Creatinine correlated acceptably but carried a consistent negative bias, and carbon dioxide, potassium and albumin did not reach acceptable agreement: the useful reading is that the panel has to be validated, not the device alone.

    Maximizing microsampling: measurement of comprehensive metabolic and lipid panels using a novel capillary blood collection deviceCollier et al., The Journal of Applied Laboratory Medicine (paywalled)

    • venous-agreement
    • blood
    • self-collection
    • capillary
    • bd-microtainer
    • liquid
    • yourbio
    • validation
    • biomarkers
  11. 2023

    Fingerstick blood self-collected into BD Microtainer tubes and posted at ambient temperature for 24 h agreed acceptably with paired serum for 11 of 12 analytes, HbA1c, lipids, creatinine, urea, urate, liver enzymes and total protein, with only AST falling outside limits.

    Capillary blood stability and analytical accuracy of 12 analytes stored in MicrotainersFontaine & Saez, Practical Laboratory Medicine

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • self-collection
    • venous-agreement
    • validation
  12. 2021

    Capillary blood collected in BD Microtainer tubes remained stable for up to 12 days at room temperature and gave accurate HbA1c results when posted back, with high return rates and patient willingness to reuse the system.

    Validation and feasibility of a postal system for remote monitoring of HbA1cCross et al., BMJ open diabetes research & care

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • self-collection
    • validation
    • acceptability
  13. 2021

    Fingerstick plasma collected in Microtainer tubes showed 100% concordance with matched venous plasma on the Abbott ARCHITECT SARS-CoV-2 IgG assay, n=109. Fingerstick dried blood spots found high concordance with venous samples, n=61, supporting these microsampling methods for decentralised serology.

    Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assaysAnderson et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology

    • blood
    • liquid
    • capillary
    • dbs
    • bd-microtainer
    • validation
    • venous-agreement
    • serology
  14. 2020

    The study found that HIV-1 viral load testing using fingerstick blood collected in BD Microtainer tubes showed high correlation, R² ≥0.980, with standard venous assays, supporting decentralised patient-centric microsampling. The authors note the limitation that testing was performed at a single laboratory site.

    Performance evaluation of the Aptima HIV-1 RNA Quant assay on the Panther system using the standard and dilution protocolsRossetti et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology (paywalled)

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • venous-agreement
    • serology
  15. 2014

    A US survey of 3,400 adults aged 62 to 90 collected up to 15 biomeasures at home, including saliva, dried blood spots and urine, with Salivette and Oragene among the devices used, which shows that several patient-centric sampling methods can run together in home-based research.

    Continuity and innovation in the data collection protocols of the second Wave of the National Social Life, Health, and Aging ProjectJaszczak et al., The journals of gerontology. Series B, Psychological sciences and social sciences (paywalled)

    • actigraphy
    • multimodal
    • blood
    • dbs
    • cortisol
    • dna-genotek-oragene
    • self-collection
    • dried
    • bd-microtainer
    • hormones
    • liquid
    • urine
    • saliva
    • biomarkers
    • genotyping