Skip to content
OpenSampling

2026 · Inflammatory bowel diseases · open access

Implementation of a Capillary Blood Self-Sampling Technique at Home for Monitoring of Patients With IBD

Schuurman et al.

The finding, in our words

This proof-of-concept study demonstrated that patients with inflammatory bowel disease could successfully perform capillary blood microsampling at home with high analytical success rates, and a majority preferred this decentralised approach over hospital venous draws.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2021

    Capillary blood collected in BD Microtainer tubes remained stable for up to 12 days at room temperature and gave accurate HbA1c results when posted back, with high return rates and patient willingness to reuse the system.

    Validation and feasibility of a postal system for remote monitoring of HbA1cCross et al., BMJ open diabetes research & care · source ↗

    • acceptability
    • multimodal
    • blood
    • rpm
    • self-collection
    • capillary
    • bd-microtainer
    • liquid
    • validation
  2. 2026

    In a 20-person proof-of-concept pilot among veterans with HIV, remote self-collection of dried blood spots for phosphatidylethanol monitoring was feasible and acceptable, with high return and analysis rates and positive feedback; a small first step toward decentralised alcohol biomarker monitoring rather than proof of it.

    Remote alcohol biomarker monitoring to promote drinking reductions among people with HIV: A proof-of-concept pilot studySheinfil et al., Journal of substance use and addiction treatment (paywalled) · source ↗

    • acceptability
    • multimodal
    • blood
    • rpm
    • dbs
    • self-collection
    • dried
    • biomarkers
  3. 2026

    In a cohort of 62 participants evaluating home self-collection with the TassoPlus device, 38 returned samples, with 29% excluded due to insufficient plasma volume below 200 ΔL. Although viral load measurements in adequate samples correlated well with conventional testing (r = 0.800), the high failure rate and missed detection in low-volume viremic samples indicate that further technical refinements are necessary before clinical adoption.

    Feasibility and reliability of decentralized HIV-1 viral load monitoring on self-sampled bloodMendes de Leon et al., PloS one · source ↗

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • serology
  4. 2025

    This meta-analysis found strong agreement between self-collected capillary blood and venous samples for laboratory results. Capillary sampling was associated with significantly lower pain scores than venipuncture, particularly when using upper arm devices rather than fingerprick methods.

    Comparison of laboratory results and pain perception in self-sampled capillary blood versus venous blood sampling: a systematic review and meta-analysisSchröder et al., Clinical biochemistry (paywalled) · source ↗

    • venous-agreement
    • acceptability
    • blood
    • self-collection
    • capillary
    • liquid
    • validation
  5. 2025

    Self-collected capillary samples showed good agreement with venous samples for most safety monitoring parameters in patients with rheumatic disease, although platelet counts were less reliable and haemolysis affected some biochemistry results. Patients found the self-sampling process easy and virtually painless, suggesting it is a feasible option for decentralised monitoring.

    Self-sampling of capillary blood for safety monitoring of DMARD therapy in patients with rheumatic disease: a feasibility and method-comparison studyAdelhelm et al., Scandinavian journal of clinical and laboratory investigation (paywalled) · source ↗

    • venous-agreement
    • acceptability
    • blood
    • self-collection
    • capillary
    • liquid