The Library
1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.
Papers 301–400 of 733 labelled “blood”, newest first.
2024
In a qualitative study of 100 service users, online postal self-sampling for STIs was valued for privacy and for overcoming barriers such as limited clinic appointments, although blood self-sampling proved challenging for most participants. Users favoured retaining clinic access for broader sexual health support, indicating that decentralised testing works best as part of a hybrid model rather than a complete replacement.
How does online postal self-sampling (OPSS) shape access to testing for sexually transmitted infections (STIs)? A qualitative study of service users — Spence et al., BMC public health
- blood
- self-collection
- acceptability
- sti
2024
Three freeze-thaw cycles, Virkon disinfectant, and air drying on Mitra microsamplers for two hours each inactivated Trypanosoma cruzi in spiked blood, while FTA C cards failed. These validated methods permit safe removal of infectious samples from containment facilities for storage and analysis, supporting decentralised diagnostics.
Validation of Trypanosoma cruzi inactivation techniques for laboratory use — MacLean et al., PloS one
- blood
- dried
- vams
- neoteryx-mitra
- validation
- serology
2024
Dried blood microsamplers (Mitra) and dried blood spots maintained metabolite stability comparable to plasma at minus 80 degrees Celsius, and both dried formats remained stable at minus 20 degrees Celsius while plasma showed reduced stability. At refrigerated temperature, Mitra microsampler profiles were more stable than plasma or dried blood spots, particularly for lipids, suggesting capillary blood microsampling could support sample collection outside clinical settings where ultra-cold storage is unavailable.
Effects of storage temperature and time on metabolite profiles measured in dried blood spots, dried blood microsamplers, and plasma — Petrick et al., The Science of the total environment (paywalled)
- blood
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- validation
- metabolome
2024
Filtered protein precipitation was the most effective extraction method for 75 per- and polyfluoroalkyl substances from dried blood spots collected with a capillary microsampler, recovering 72 analytes within 70–130% with limits of detection from 0.05 to 0.34 ng/mL. The method detected 16 PFAS in self-collected human samples, demonstrating feasibility for large-scale biomonitoring studies using minimally invasive sampling.
Validating blood microsampling for per- and polyfluoroalkyl substances quantification in whole blood — Partington et al., Journal of chromatography. A (paywalled)
- blood
- dried
- capillary
- dbs
- validation
- toxicology
2024
Among 1,423 people who use drugs across 21 community centres, a decentralised care programme using dried blood spot testing achieved a 93% cure rate in those who completed hepatitis C therapy and were monitored. Over 90% of participants accepted the decentralised screening and treatment approach, showing patient-centric microsampling can improve healthcare access for stigmatised populations.
Implementing a new HCV model of care for people who use drugs — Herranz Mochales et al., JHEP reports : innovation in hepatology
- blood
- dried
- dbs
- acceptability
- dct
- serology
2024
Capillary dried blood spots collected during professional triathlon competitions detected endogenous erythropoietin in all 111 athletes using Tasso-M20 devices, even when matching urine samples were negative. Mitra VAMS devices also sensitively detected recombinant EPO micro-doses and the EPO c.577del variant, confirming that microsampling provides a viable complementary matrix for decentralised doping analysis.
Dried blood spots for erythropoietin analysis: Detection of micro-doses, EPO c.577del variant and comparison with in-competition matching urine samples — Heiland et al., Drug testing and analysis (paywalled)
- blood
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- validation
- doping
2024
Dried blood spots stored at ambient temperature for up to 15 years retained sufficient DNA quantity and integrity for some genomic applications, but were of limited use for viral pathogen research, especially RNA viruses. This suggests DBS can support decentralised genomics but may not be reliable for RNA virus diagnostics without additional stabilisation.
Nucleic acid degradation after long-term dried blood spot storage — Li et al., Molecular ecology resources
- blood
- dried
- dbs
2024
Sixty-nine metabolites in dried blood spots remained stable across storage temperatures of 4°C, 25°C and 40°C for 21 days, whereas seventy-eight metabolites showed instability, with phosphatidylcholines and triglycerides most affected. This demonstrates that storage conditions materially alter metabolite integrity, which is critical for biomarker selection and data quality in patient-centric, home-sampling protocols.
Evaluation of metabolite stability in dried blood spot stored at different temperatures and times — Cui et al., Scientific reports
- blood
- dried
- dbs
- metabolome
- biomarkers
2024
In young elite footballers with regular cycles, salivary progesterone correlated strongly with capillary blood concentrations, offering a non‑invasive way to track ovarian function. A luteal‑phase saliva progesterone threshold of 50 pg/ml and a 1.5‑fold rise over follicular baseline showed good accuracy for confirming ovulation against serum criteria.
The use of saliva and blood progesterone to profile the menstrual cycles of youth professional football players — Ferrer et al., Frontiers in sports and active living
- blood
- saliva
- capillary
- validation
- fertility
- hormones
2024
Fifty-eight matched capillary and venous blood samples collected under official doping control conditions demonstrated excellent laboratory agreement for complete blood count parameters (except platelets) after temperature-monitored air shipment. This validates micro capillary collection as a virtually painless, athlete-friendly alternative to venipuncture for the Athlete Biological Passport, supporting its use in decentralised diagnostics.
Application of micro capillary blood sampling in an anti-doping setting — Lewis et al., Drug testing and analysis (paywalled)
- blood
- capillary
- validation
- venous-agreement
- doping
2024
Self-collected dried blood spots were used to assess HIV status at 12 months in 1168 participants. Integration of sexual and reproductive health services increased linkage to HIV prevention care within 60 days (adjusted odds ratio 1·68) compared with standard referral, whereas peer support had no effect.
Effectiveness of integrating HIV prevention within sexual reproductive health services with or without peer support among adolescents and young adults in rural KwaZulu-Natal, South Africa (Isisekelo Sempilo): 2 × 2 factorial, open-label, randomised controlled trial — Shahmanesh et al., The lancet. HIV (paywalled)
- blood
- dried
- dbs
- self-collection
- dct
- serology
- sti
2024
The authors validated an LC-MS/MS method for quantifying 18 endogenous steroids and metabolites in 30 μL dried blood VAMS samples from 20 healthy volunteers. Steroids remained stable for up to 100 days across storage temperatures from room temperature to -80 °C and through three freeze-thaw cycles, suggesting VAMS is reliable for doping control and clinical hormone monitoring outside traditional settings.
LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling (VAMS) for doping control purposes — Ponzetto et al., Clinica chimica acta; international journal of clinical chemistry (paywalled)
- blood
- dried
- vams
- validation
- hormones
- doping
- toxicology
2024
Self-collected dried blood spots showed high specificity and acceptable sensitivity for detecting islet antibodies compared to serum samples, and participants preferred this method over venous blood draw for its ease and reduced pain.
Feasibility and Validity of In-Home Self-Collected Capillary Blood Spot Screening for Type 1 Diabetes Risk — Sing et al., Diabetes technology & therapeutics (paywalled)
- blood
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
2024
In 30 adult solid organ transplant recipients, capillary blood self-collected using the Tasso+ device showed 91% concordance with venous samples for detecting CMV DNAemia above the limit of detection, with excellent quantitative correlation (Spearman R² = 0.99). Most participants preferred self-collection over venipuncture, suggesting the device could enable decentralised viral monitoring, though sensitivity was lower (95% at 308 IU/mL).
Evaluation of the Tasso+ blood self-collection device for quantitation of plasma cytomegalovirus (CMV) DNAemia in adult solid organ transplant recipients (SOTr) — Phan et al., Microbiology spectrum
- blood
- liquid
- capillary
- self-collection
- validation
- venous-agreement
- acceptability
- serology
2024
Older adults achieved 98% adherence when self-collecting dried blood spots at home for inflammatory markers, with 97% of samples yielding valid results. Test-retest reliability was good (ICCs 0.70–0.76) and correlation with venous blood was strong (r=0.60–0.99), demonstrating that remote capillary sampling is a feasible and valid method for decentralised assessment of inflammation in older adults.
Remote dried blood spot collection for inflammatory markers in older adults is feasible, reliable, and valid — Reed et al., Brain, behavior, and immunity (paywalled)
- blood
- dried
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
- biomarkers
2024
Adolescents collecting blood microsamples at home achieved varying success rates across six devices, with Minicollect tubes performing poorest. The confirmation that visual inspection alone was insufficient, by analytical variability, underscores the need for robust quality assessment before deploying any device in decentralised trials.
Self-Sampling by Adolescents at Home: Assessment of the Feasibility to Successfully Collect Blood Microsamples by Inexperienced Individuals — Boffel et al., The AAPS journal (paywalled)
- blood
- liquid
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- self-collection
- acceptability
- pediatric
- dct
2023
A study of 50 paediatric renal transplant recipients found that a validated VAMS LC-MS/MS method for tacrolimus showed high correlation with the reference method over 0.5–60 ng/mL, with minimal haematocrit effect.
Therapeutic Drug Monitoring of Tacrolimus Based on VAMS in Renal Transplant Pediatric Recipients — LC-MS/MS Method, Hematocrit Effect, and Clinical Application — Kocur et al., Pharmaceutics
- vams
- neoteryx-mitra
- blood
- tdm
- haematocrit
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2023
VAMS microsampling found no significant difference from venous blood for tacrolimus in paediatric patients; samples were stable for 14 days, with average difference between paired at-home samples of 0.12 ± 0.94 ng/mL.
VAMS and parallel-reaction-monitoring mass spectrometry for tacrolimus trough measurements at home in paediatric heart-transplant patients — Zhao et al., J. Mass Spectrometry and Advances in the Clinical Lab
- vams
- venous-agreement
- acceptability
- blood
- dbs
- tdm
- self-collection
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2023
A structured review: many VAMS assays are analytically validated and can substitute for venous sampling for well-characterised analytes, though clinical-validation depth varies.
Analytical and Clinical Validation of Assays for VAMS of Drugs in Different Blood Matrices: A Literature Review — Nugraha et al., Molecules
- vams
- venous-agreement
- blood
- tdm
- dried
- immunosuppressants
- validation
2023
VAMS matched serum for the kinase inhibitors nilotinib, cabozantinib, dabrafenib and ruxolitinib, r 0.94–0.97, with serum reliably predictable for the first three, and 93% of at-home samples were collected correctly: at-home VAMS shown feasible for routine cancer-drug monitoring.
Clinical validation and feasibility of VAMS for monitoring of nilotinib, cabozantinib, dabrafenib, trametinib and ruxolitinib — Zimmermann et al., J. Pharmaceutical and Biomedical Analysis (paywalled)
- vams
- venous-agreement
- acceptability
- blood
- tdm
- self-collection
- haematocrit
- dried
- oncology
- capillary
- validation
2023
In children, VAMS and dried plasma spot voriconazole, posaconazole and isavuconazole correlated with fresh plasma, Spearman 0.82–0.94, and stayed stable at room temperature for at least 14 days: refrigeration-free antifungal TDM in paediatrics.
VAMS and dried plasma spot for antifungal triazole agents (voriconazole, posaconazole, isavuconazole) in pediatric patients by LC-MS/MS — Simeoli et al., J. Pharmaceutical and Biomedical Analysis (paywalled)
- vams
- neoteryx-mitra
- blood
- tdm
- dried
- antimicrobials
- pediatric
2023
A UHPLC-HRMS assay quantified 25-hydroxyvitamin D2 and D3 from 20 µL Mitra VAMS samples with accuracy under 10% and precision under 11%, LOQ 5 ng/mL: sensitive enough to flag deficiency and simple enough for untrained self-collection, enabling year-round vitamin-D monitoring.
Quantification of 25-hydroxyvitamin D2 and D3 in Mitra devices (VAMS) by UHPLC-HRMS for regular vitamin D status monitoring — Tuma et al., J. Pharmaceutical and Biomedical Analysis (paywalled)
- vams
- neoteryx-mitra
- blood
- self-collection
- dried
- capillary
- validation
- biomarkers
2023
Capillary VAMS blood covered more of the metabolome than plasma, capturing intracellular red-cell metabolites, and correlated moderately-to-well with venous, Spearman 0.66; the honest caveats are higher finger-prick replicate variability and a need for −80 °C storage within six hours.
VAMS-based blood capillary sampling for mass-spectrometry-based human metabolomics studies — Volani et al., Metabolites
- vams
- venous-agreement
- blood
- metabolome
- dried
- capillary
- validation
- biomarkers
2023
During ACTH stimulation, salivary cortisol correlated only weakly with serum and gave modest accuracy: saliva does not reliably replace serum cortisol for adrenal insufficiency. A concrete limit.
Reliability of Salivary versus Serum Cortisol for Diagnosing Adrenal Insufficiency in Children — Ciancia et al., Children
- venous-agreement
- blood
- cortisol
- pediatric
- hormones
- liquid
- validation
- saliva
2023
TAP II capillary serum, both professionally collected and self-collected, correlated with venous serum at R > 0.9 for eight analytes including ALT, AST, cholesterol, HDL and triglycerides. Creatinine correlated acceptably but carried a consistent negative bias, and carbon dioxide, potassium and albumin did not reach acceptable agreement: the useful reading is that the panel has to be validated, not the device alone.
Maximizing microsampling: measurement of comprehensive metabolic and lipid panels using a novel capillary blood collection device — Collier et al., The Journal of Applied Laboratory Medicine (paywalled)
- venous-agreement
- blood
- self-collection
- capillary
- bd-microtainer
- liquid
- yourbio
- validation
- biomarkers
2023
Fingerstick blood self-collected into BD Microtainer tubes and posted at ambient temperature for 24 h agreed acceptably with paired serum for 11 of 12 analytes, HbA1c, lipids, creatinine, urea, urate, liver enzymes and total protein, with only AST falling outside limits.
Capillary blood stability and analytical accuracy of 12 analytes stored in Microtainers — Fontaine & Saez, Practical Laboratory Medicine
- blood
- liquid
- capillary
- bd-microtainer
- self-collection
- venous-agreement
- validation
2023
This review evaluates established and emerging capillary blood sampling techniques, comparing factors such as wound geometry and patient comfort, and identifies microneedles as a promising option for paediatric care because they can obtain samples virtually painlessly.
Minimally invasive capillary blood sampling methods — Hoffman et al., Expert review of medical devices (paywalled)
- blood
- capillary
- validation
- acceptability
- pediatric
2023
In 28 healthy adults, alectinib concentrations from capillary microsamples were generally similar to venous ones, which supports the method for therapeutic drug monitoring; the study tested a paediatric-friendly suspension, and the authors point to children, for whom venepuncture is difficult, as the intended use.
Relative bioavailability and food effect study of an oral suspension of alectinib in healthy volunteers using venipuncture and capillary microsampling — Liu et al., Clinical and translational science
- blood
- capillary
- venous-agreement
- pediatric
- tdm
- oncology
2023
Dried blood spot microsampling shows that paediatric lipid profiles vary significantly across three age groups, 0-10 days, 2-18 months and 3-13 years, with differences in 16 specific lipid species. The authors caution that paediatric ages remain under-mapped in DBS lipidomics and further investigation is required before establishing reference standards.
Lipid profile variability in children at different ages measured in dried blood spots — Ferreira et al., Molecular omics (paywalled)
- blood
- dbs
- metabolome
- dried
- pediatric
- biomarkers
2023
A new method using a direct mercury analyser allows for precise total mercury measurement in dried blood spot samples while controlling for sample volume. This approach facilitates minimally invasive capillary blood collection, making it highly suitable for human biomonitoring studies in vulnerable populations such as children.
A simple method for direct mercury analysis in dried blood spots (DBS) samples for human biomonitoring studies — González-Rubio et al., Environment international (paywalled)
- blood
- dried
- dbs
- validation
- pediatric
- toxicology
2023
A validated LC-MS/MS method successfully quantified vincristine in paediatric patient-centric whole blood collected via VAMS microsampling, spanning 1 to 50 ng/mL with intra- and inter-accuracy and precision within ±10.3% and ≤7.3%. Whole blood concentrations showed a non-linear relationship to plasma concentrations, which was described by a saturable binding model.
A sensitive liquid chromatographic-mass spectrometry method for the quantification of vincristine in whole blood collected with volumetric absorptive microsampling — van et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- blood
- vams
- validation
- pediatric
- tdm
- oncology
2023
A study of 50 paediatric renal transplant recipients found that a UHPLC-MS/MS method successfully quantified mycophenolic acid in VAMS microsampling samples over a 0.10-15 µg/mL range. However, converting microsampling results to plasma equivalents using haematocrit-based regression is required for clinical interpretation, supporting patient-centric decentralised monitoring.
Therapeutic drug monitoring of mycophenolic acid (MPA) using volumetric absorptive microsampling (VAMS) in pediatric renal transplant recipients: ultra-high-performance liquid chromatography-tandem mass spectrometry analytical method development, cross-validation, and clinical application — Kocur et al., Pharmacological reports : PR
- vams
- venous-agreement
- blood
- tdm
- haematocrit
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2023
Self-collection of capillary blood using a topper and paediatric tube was successful for most patients under 70 and showed excellent agreement with venous sampling for PSA measurement, supporting its use for decentralised patient monitoring.
Self-sampling of blood using a topper and pediatric tubes; a prospective feasibility study for PSA analysis using 120 prostate cancer patients — van et al., Clinical chemistry and laboratory medicine (paywalled)
- venous-agreement
- blood
- self-collection
- oncology
- capillary
- liquid
2023
In 26 participants, capillary self-collection with Tasso-SST showed no qualitative discrepancies from venous phlebotomy for SARS-CoV-2 antibody results, and quantitative levels correlated strongly, total Ig Spearman rho 0.72 and IgG 0.85; within the limits of so small a study, this supports at-home collection for serosurveillance.
Comparison of capillary blood self-collection using the Tasso-SST device with venous phlebotomy for anti-SARS-CoV-2 antibody measurement — King et al., Journal of immunological methods (paywalled)
- venous-agreement
- blood
- self-collection
- serology
- capillary
- liquid
2023
A study of 37 kidney transplant recipients found Capitainer and Mitra microsampling feasible for decentralised monitoring. Capitainer showed consistent sampling success, 92%-96%, and higher analytical accuracy than Mitra, 52%-88% success. Proportions within ±15% of venous reference for creatinine and haemoglobin were 92%-100% and 93%-100% for Capitainer, versus 79%-96% and 67%-92% for Mitra, despite small cohorts.
Clinical performance of volumetric finger-prick sampling for the monitoring of tacrolimus, creatinine and haemoglobin in kidney transplant recipients — Vethe et al., British journal of clinical pharmacology (paywalled)
- blood
- capillary
- qdbs
- volumetric
- neoteryx-mitra
- self-collection
- validation
- venous-agreement
- tdm
- immunosuppressants
2023
The Tasso+ capillary blood collection device showed substantial to almost perfect concordance with standard venipuncture for measuring abnormal liver function tests including ALT, ALP, AST and total bilirubin, and patient feedback indicated a very favourable experience, supporting its use for more frequent and convenient testing outside the clinic.
Standard Venipuncture vs a Capillary Blood Collection Device for the Prospective Determination of Abnormal Liver Chemistry — Wickremsinhe et al., The journal of applied laboratory medicine (paywalled)
- blood
- capillary
- validation
- venous-agreement
- acceptability
2023
In a 16-donor validation study, prompt centrifugation of serum microsamples maintained analyte stability and preserved clinical chemistry and protein biomarker quality. This demonstrates that remote centrifugation with refrigerated shipping can lessen patient burden and broaden participation in decentralised clinical trials.
Decentralized clinical trial design using blood microsampling technology for serum bioanalysis — Lee et al., Bioanalysis (paywalled)
- blood
- liquid
- validation
- venous-agreement
- dct
- biomarkers
2023
Dried blood spot eluates showed high agreement with serum for SARS-CoV-2 IgG against Spike and Nucleocapsid (r≈0.96; qualitative φ≈0.98–1.0) and remained stable after 6–8 hours of storage, supporting use of capillary DBS for serosurveys and decentralised testing.
Dried blood spot eluates are suitable for testing of SARS-CoV-2 IgG antibodies targeting Spike protein 1 and Nucleocapsid protein — Guttmann et al., Biochemistry and biophysics reports
- blood
- dried
- capillary
- self-collection
- validation
- venous-agreement
- serology
2023
A remote protocol combining daily surveys with weekly self-collected dried blood spots achieved a 92% study completion rate and high acceptability among reproductive-age women smokers, with 87% of participants collecting most samples and the same proportion extremely willing to repeat the study. This feasibility demonstrates that decentralised microsampling can support longitudinal research on hormonal contraceptive effects and smoking behaviour.
Feasibility of remotely assessing hormonal contraceptive use and smoking-related symptomatology: Evidence from a preliminary prospective cohort study — Medvescek & Allen, Drug and alcohol dependence reports (paywalled)
- blood
- dried
- dbs
- self-collection
- acceptability
- fertility
- hormones
- dct
2023
Volumetric absorptive microsampling of whole blood did not provide a reliable basis for calculating meropenem plasma concentrations in critically ill children, so a validated low volume plasma method was required for paediatric therapeutic drug monitoring.
Developing a Method for Quantifying Meropenem in Children-Volumetric Adsorptive Microsampling Versus Plasma Sampling — Ramadan et al., Therapeutic drug monitoring (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- venous-agreement
- pediatric
- tdm
- antimicrobials
2023
Volumetric absorptive microsampling (VAMS) of whole blood allows depletion of abundant red-cell proteins during processing, which improves detection of less abundant proteins from all blood compartments and yields deeper proteomic coverage than conventional plasma analysis alone.
Proteome Analysis of Whole Blood Collected by Volumetric Absorptive Microsampling — Molloy et al., Methods in molecular biology (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- biomarkers
2023
Lead can be measured accurately in dried blood spots by ICP-MS only when matrix-matched calibrators are used; aqueous calibrators perform poorly. The three methods evaluated showed strong agreement with whole blood analysis and offer a robust option for decentralised lead screening in children, though the recognised limitations of dried blood spots remain.
Matrix-matched calibrators are necessary for robust and high-quality dried blood spots lead screening assays by inductively coupled plasma-mass spectrometry — Franco et al., Journal of mass spectrometry and advances in the clinical lab
- blood
- dried
- dbs
- validation
- venous-agreement
- pediatric
- toxicology
2023
The authors validated a simultaneous LC-MS/MS assay for hydroxychloroquine, its metabolites, and azithromycin from self-collected dried blood spots. Requiring only ten microlitres of blood and achieving a sensitivity of one nanogram per millilitre, the method enabled remote therapeutic drug monitoring in more than two thousand specimens during the COVID-19 pandemic.
Simultaneous LC-MS/MS method for the quantitation of Azithromycin, Hydroxychloroquine and its metabolites in SARS-CoV-2(-/ +) populations using dried blood spots — Chhonker et al., Scientific reports
- blood
- dried
- dbs
- self-collection
- validation
- tdm
2023
Capillary finger-stick dried blood spots yielded TSH measurements that agreed strongly with venous plasma (R² 0.988) and correctly identified hypothyroidism and hypothyrotropinemia in most cases. The analyte remained stable for at least four days between -20°C and +30°C, indicating potential for at-home collection in thyroid diagnostics and monitoring.
A Preliminary Analysis of Thyrotropin Measurement from Finger Stick Dried Blood Spot with an Automated High-Throughput Immunoassay Analyzer — Schakelaar et al., Thyroid : official journal of the American Thyroid Association (paywalled)
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- hormones
- haematocrit
2023
In term newborns, measuring thyroid-stimulating hormone from dried blood spots before 72 hours of life is as accurate as later sampling and enables treatment of positive cases around 6 days instead of 8.5 days, without increasing false positives; however, home sampling delays laboratory receipt and yields more unusable samples than hospital sampling.
Thyrotropin Screening of Newborns: Before or After 72 Hours of Life? Before Discharge or at Home? — Boros et al., Thyroid : official journal of the American Thyroid Association (paywalled)
- blood
- dried
- dbs
- self-collection
- pediatric
- hormones
2023
The analysis quantified 62 proteins with satisfactory analytical performance, and 48 proteins showed significant correlation between 2 µL plasma microsamples and dried blood spots, supporting the use of dried blood microsampling for home collection and predictive medicine in elderly patients.
New Perspectives of Multiplex Mass Spectrometry Blood Protein Quantification on Microsamples in Biological Monitoring of Elderly Patients — Vialaret et al., International journal of molecular sciences
- blood
- liquid
- dried
- dbs
- validation
- biomarkers
2023
The study found that serum concentrations of lacosamide and levetiracetam can be accurately estimated from dried capillary blood samples using simple ratio conversion, with high agreement to measured serum levels, supporting their use in decentralised therapeutic drug monitoring. For lamotrigine, the method is acceptable at low to medium concentrations but less reliable at higher levels, indicating a need for cautious interpretation in clinical practice.
Validation of Conversion Factors for Therapeutic Drug Monitoring of Lacosamide, Lamotrigine, and Levetiracetam in Dried Capillary Blood — Hagemann et al., Therapeutic drug monitoring (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
2023
In healthy Chinese adults a single oral dose of padsevonil showed rapid absorption and a favourable safety profile. VAMS dried blood concentrations of padsevonil and its metabolites were generally lower than plasma but were comparable at some time points by Passing‑Bablok regression, indicating that VAMS is promising for therapeutic drug monitoring of this novel antiepileptic drug and warrants further validation.
Pharmacokinetics and safety of Padsevonil in healthy Chinese subjects and comparison of two sampling methods for Padsevonil quantification — Li et al., European review for medical and pharmacological sciences (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
2023
The study optimised a UHPLC-MS/MS method to measure 11 lipids in 2.74 µL blood microsamples collected with hemaPEN® devices directly from athletes on a track. Five analytes, arachidonic acid, sphingosine, lactic acid, and two lysophosphatidylcholines, showed significant exercise-induced changes, demonstrating that capillary microsampling can reliably capture metabolic responses in decentralised settings without specialist staff.
A targeted UHPLC-MS/MS method to monitor lipidomic changes during a physical effort: Optimization and application to blood microsamples from athletes — Laurent et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- blood
- capillary
- validation
- metabolome
- biomarkers
2023
Capillary blood collected in microtubes yielded HbA1c results that agreed closely with venous sampling, while dried blood spots showed markedly poorer agreement. High patient acceptability and willingness to repeat suggest microtubes are a viable option for decentralised diabetes monitoring.
Home monitoring of haemoglobin A<sub>1c</sub> in diabetes: A systematic review and narrative synthesis on accuracy, reliability and patient acceptability — Colley et al., Diabetic medicine : a journal of the British Diabetic Association (paywalled)
- blood
- liquid
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
2023
Self-collected capillary blood produces serum creatinine results comparable to venous blood, and the analyte remains stable in unspun capillary samples stored at ambient temperature for three days. This supports the use of capillary microsampling for kidney function monitoring in patient-centric, decentralised settings.
Comparability and Stability of Serum Creatinine Concentration in Capillary and Venous Blood — Woolley et al., British journal of biomedical science
- blood
- liquid
- capillary
- validation
- venous-agreement
2023
Internet-based self-sampling of dried blood spots for HIV total nucleic acid testing was feasible, with a 95% qualification rate and good confidentiality, and it complemented sentinel surveillance.
A novel internet sampling for HIV surveillance: feasibility of self-sampling and preparation of DBS for delivery detection of HIV total nucleic acid and complementarity to sentinel surveillance — Su et al., BMC infectious diseases
- blood
- dried
- dbs
- self-collection
- serology
- sti
2023
This study of 184 individuals showed that home collection of dried blood spots and saliva can identify genetic polymorphisms linked to cardiac serum markers. Seven SNPs associated significantly with markers such as Apo B, LDL Direct, and hsCRP, while a polygenic risk score correlated strongly with NT-proBNP (r²=0.82, P=.03) and ox-LDL (r²=0.94, P=.005). These results indicate decentralised genetic sampling could enable early cardiovascular risk assessment and identify patients requiring closer serological monitoring.
Influence of genetic polymorphisms on serum biomarkers of cardiac health — Krishnamurthy et al., Medicine
- blood
- saliva
- dried
- dbs
- self-collection
- genotyping
- biomarkers
2023
In 1070 young adults, dried blood spot eluates correlated strongly with serum for anti-spike IgGAM and total IgG, IgA and IgM; labDBS achieved 82.0% sensitivity and 98.2% specificity and ssDBS 86.1% sensitivity and 96.7% specificity versus serum, with minimal difference between self and investigator collection.
Validation of dried blood spot sampling for detecting SARS-CoV-2 antibodies and total immunoglobulins in a large cohort of asymptomatic young adults — Ferentinos et al., Journal of immunological methods
- blood
- dried
- dbs
- self-collection
- validation
- venous-agreement
- serology
2023
Self-collection of dried blood spots in the home was feasible for healthy youth, with 82% consenting to provide a sample in the lab and 75% of those willing to self-collect at home, and DNA extraction quality was high across demographic groups.
At-home dried blood spot (DBS) collection to increase population heterogeneity representation in pediatric research: An ECHO study — Green et al., Frontiers in pediatrics
- blood
- dried
- dbs
- self-collection
- pediatric
2023
Dried blood spot sampling shows moderate agreement with plasma for therapeutic drug monitoring across evaluated drugs, and home based DBS achieves high yield and adherence with patient preference around three quarters; DBS is a reliable and feasible option for decentralised TDM but needs careful design and evaluation before use.
Reliability and feasibility of home-based dried blood spot in therapeutic drug monitoring: a systematic review and meta-analysis — Xiaoyong et al., European journal of clinical pharmacology (paywalled)
- blood
- dried
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
- tdm
2023
A VAMS method using Mitra devices for whole blood lead quantification showed no significant difference compared with the centre's routine method, supporting VAMS as a practical alternative for blood lead and other trace element analyses.
Method development for the quantification of lead levels in whole blood sampled on Mitra<sup>®</sup> with VAMS<sup>®</sup> tips by inductively coupled plasma-MS/MS — Breton et al., Bioanalysis (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- venous-agreement
- toxicology
2023
Capillary blood collected with the Mitra® device showed correlation with venous samples for paclitaxel therapeutic drug monitoring, but wide confidence intervals suggest the methods may not be interchangeable. While plasma and whole blood concentrations were more closely aligned, the variability raises questions about using self-collected capillary samples for dose individualisation without further validation.
Paclitaxel and Therapeutic Drug Monitoring with Microsampling in Clinical Practice — Radovanovic et al., Pharmaceuticals
- blood
- liquid
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- oncology
2023
The authors developed and validated a workflow that couples Mitra volumetric absorptive microsampling with hybridisation LC-MS/MS to quantify the antisense oligonucleotide fomivirsen in human blood. Quantitative recovery was achieved irrespective of haematocrit level or sample age, and the method demonstrated sensitivity, linearity, precision, accuracy, and four-month stability, supporting its use for therapeutic drug monitoring of biologic candidates in decentralised trials.
Volumetric absorptive microsampling coupled with hybridization LC-MS/MS for quantitation of antisense oligonucleotides — Chen et al., Bioanalysis (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- haematocrit
2023
Patient-collected dried blood spot specimens for phenylketonuria monitoring showed significant quality variability across ten UK laboratories, with rejection rates rising from a median of 4.0% under existing local criteria to 21.9% under proposed national guidelines, most commonly because spots were too small or multi-spotted. The authors estimate that accepting poor-quality specimens could lead to approximately 12,410 incorrect results annually in England, and recommend ongoing training for patients and carers to prevent distress from higher rejection rates.
Cross-sectional audit assessing the quality of dried bloodspot specimens received by UK metabolic biochemistry laboratories for the biochemical monitoring of individuals with Phenylketonuria — Hogg et al., Annals of clinical biochemistry (paywalled)
- blood
- dried
- dbs
- self-collection
2023
In 102 samples, quantitative TSH by Finecare LFIA showed strong correlation (r approximately 0.93) and excellent agreement (Cohen's kappa 0.85) with the Roche CobasPro reference; using serum, sensitivity was 90.5% and specificity 96.3% for diagnosing thyroid abnormalities, supporting fingerstick and whole-blood use for decentralised TSH testing.
High-sensitive detection and quantitation of thyroid-stimulating hormone (TSH) from capillary/fingerstick and venepuncture whole-blood using fluorescence-based rapid lateral flow immunoassay (LFIA) — Shurbaji et al., Heliyon
- blood
- liquid
- capillary
- validation
- venous-agreement
- hormones
2023
The study found that smartwatch-based adherence monitoring showed consistent concordance over time and may be more reliable than app or pill count methods in measuring treatment adherence in a decentralised setting. This supports the use of wearable devices as objective tools in patient-centric monitoring for decentralised clinical trials.
Exploration of smart adherence-monitoring methods in vitamin D-deficient patients: A pilot feasibility clinical study — Huh et al., Clinical and translational science
- blood
- dct
- wearable
- digital-biomarker
- multimodal
2023
University branding increased trust and confidence in results, plain packaging promoted discretion, and colour‑coded bags with matching instructions reduced confusion; participants recommended instructional videos, tailored test options, real‑time introductions and personalised reminders to maximise return rates.
Lessons Learned From the Implementation of a Pilot Study on Self-collected Specimen Return by Sexual Minority Men (Project Caboodle!): Qualitative Exploration — Sallabank et al., JMIR formative research
- blood
- urine
- capillary
- self-collection
- acceptability
- sti
2023
The study demonstrated that qPCR-based epigenetic immune cell counting from capillary dried blood spots agreed with venous blood and conventional flow cytometry in healthy donors, and then identified lymphopenia, neutrophilia and a lowered lymphocyte-to-neutrophil ratio in 103 COVID-19 patients versus 113 healthy controls, with naive B cell frequency tracking disease severity, suggesting that filter-paper blood collection could enable remote immune monitoring in home-isolated patients.
Epigenetic immune monitoring for COVID-19 disease course prognosis — Samans et al., Frontiers in immunology
- blood
- liquid
- dried
- capillary
- validation
- venous-agreement
- serology
2023
In kidney transplant recipients, home capillary blood self-testing of creatinine using a handheld analyser showed good agreement with clinic venous laboratory results, whereas potassium showed poorer agreement; patient self-use of the device was not a significant source of the potassium difference.
Patient Self-Testing of Kidney Function at Home, a Prospective Clinical Feasibility Study in Kidney Transplant Recipients — Murray et al., Kidney international reports
- blood
- liquid
- capillary
- self-collection
- venous-agreement
2023
The Ser-Col dried blood device with automated elution matched plasma gold-standard results for HIV and showed comparable performance to conventional DBS for HBV, HCV and syphilis across 378 miners at remote sites in French Guiana, with full HIV concordance and 87 per cent sensitivity for treponemal antibodies, supporting automated dried blood testing for large-scale infectious disease screening in remote populations.
Automated and combined HIV, HBV, HCV, and syphilis testing among illegal gold miners in French Guiana using a standardized dried blood device — Pisoni et al., Acta tropica (paywalled)
- blood
- dried
- dbs
- validation
- venous-agreement
- serology
- sti
2023
The study found that congenital cytomegalovirus infection is significantly associated with asymmetric bilateral and profound sensorineural hearing loss in children, based on retrospective analysis of dried blood spot testing. This supports the use of decentralised microsampling for early identification of at-risk children, enabling timely intervention.
Factors associated with congenital cytomegalovirus infection detected by dried blood spot testing in children with hearing loss — Liao et al., International journal of pediatric otorhinolaryngology (paywalled)
- blood
- dried
- dbs
- pediatric
- serology
2023
Early at-home VAMS samples allowed Bayesian forecasting of steady-state adalimumab concentrations with modest bias (mean prediction error -2.6%) and acceptable precision (normalised RMSE 24.0%), correctly classifying 75% of predictions within the therapeutic window and identifying 8.3% of patients who developed anti-adalimumab antibodies, supporting decentralised precision dosing during induction.
Early At-Home Measurement of Adalimumab Concentrations to Guide Anti-TNF Precision Dosing: A Pilot Study — de Klaver et al., European journal of drug metabolism and pharmacokinetics (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- self-collection
- tdm
- biologics
2023
The study found that blood concentrations of padsevonil measured using Mitra devices can reliably predict plasma concentrations with less than 9% mean bias, supporting the use of VAMS as a patient-centric alternative to venous sampling in decentralised trials. This validation strengthens confidence in microsampling for therapeutic drug monitoring where venous draws are impractical.
Clinical Bridging Studies and Modeling Approach for Implementation of a Patient Centric Sampling Technique in Padsevonil Clinical Development — Kramer et al., The AAPS journal (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- dct
2023
A UHPLC-MS/MS method for measuring Fabry disease biomarkers in dried blood spots was validated using both conventional cards and Capitainer B devices. Capillary blood gave similar results to venous blood across a wide haematocrit range, supporting decentralised screening and longitudinal monitoring of patients.
Mass Spectrometry Analysis of Globotriaosylsphingosine and Its Analogues in Dried Blood Spots — Boutin et al., International journal of molecular sciences
- blood
- dried
- capillary
- dbs
- validation
- venous-agreement
- haematocrit
- biomarkers
2023
The study found that dried blood spot sampling for HIV viral load monitoring achieved high coverage over 24 months in remote settings in Vietnam, with no difference in access between people who inject drugs and other patients. However, virological failure was more common in people who inject drugs, those with poor adherence and those late to clinical visits, highlighting the need for targeted support to improve outcomes in decentralised care.
Assessment of HIV viral load monitoring in remote settings in Vietnam - comparing people who inject drugs to the other patients — Lefrancois et al., PloS one
- blood
- dried
- dbs
- serology
2023
The authors developed a capillary microfluidic device that captures multiple blood biomarkers at collection and dries them on-chip, enabling safe shipment to centralised laboratories for multiplexed analysis. This patient-centric approach could support remote health monitoring and decentralised trials.
Microfluidic Device for Patient-Centric Multiplexed Assays with Readout in Centralized Laboratories — Hauser et al., Analytical chemistry
- blood
- dried
- capillary
- dct
- biomarkers
2023
Automated dried blood spot analysis achieved clinical and analytical acceptance criteria for tacrolimus, sirolimus, everolimus and cyclosporin A after haematocrit correction. This validates a method that could enable decentralised, patient-centric therapeutic drug monitoring for transplant recipients.
Application of a Fully Automated Dried Blood Spot Method for Therapeutic Drug Monitoring of Immunosuppressants: Another Step Toward Implementation of Dried Blood Spot Analysis — Deprez & Stove, Archives of pathology & laboratory medicine (paywalled)
- blood
- dried
- dbs
- validation
- venous-agreement
- tdm
- immunosuppressants
- haematocrit
2023
In participants 11 months after SARS-CoV-2 infection, the nano-immunoassay achieved 98.33% sensitivity and 97.62% specificity on venous serum. When combined with dried capillary microsampling, sensitivity was 95.05% with Mitra, 61.11% with repurposed glucose strips and 83.16% with HemaXis (91.49% after automated extraction), with no loss of specificity, supporting home-based sampling for serology.
Clinical sensitivity and specificity of a high-throughput microfluidic nano-immunoassay combined with capillary blood microsampling for the identification of anti-SARS-CoV-2 Spike IgG serostatus — Michielin et al., PloS one
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- serology
2023
VAMS finger-prick microsampling showed reliable agreement with venous blood sampling for measuring tacrolimus and creatinine after correction for systematic differences, supporting its use in therapeutic drug monitoring. This offers a patient-centric, decentralised alternative to frequent venipunctures in kidney transplant recipients.
Serum Creatinine and Tacrolimus Assessment With VAMS Finger-Prick Microsampling: A Diagnostic Test Study — Scuderi et al., Kidney medicine
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- immunosuppressants
2023
VAMS capillary samples from 32 liver transplant recipients showed strong agreement with venous blood for everolimus measurement, with a correlation of r squared 0.92 and no proportional or constant bias on Bland Altman analysis. No effect of haematocrit or sampling time was observed, supporting VAMS as a virtually painless decentralised alternative to venous draws for immunosuppressant monitoring in transplant patients.
Volumetric Absorptive Microsampling for the Therapeutic Drug Monitoring of Everolimus in Patients Who Have Undergone Liver Transplant — Yoo et al., Therapeutic drug monitoring (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- venous-agreement
- tdm
- immunosuppressants
- haematocrit
2023
Researchers developed and validated a volumetric absorptive microsampling method for cariprazine therapeutic drug monitoring in psychiatric patients. The approach showed strong agreement with conventional plasma analysis, offering a minimally invasive alternative that could support decentralised monitoring programmes.
Volumetric absorptive microsampling for the therapeutic drug monitoring of psychiatric patients treated with cariprazine — Millán-Santiago et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- blood
- dried
- vams
- validation
- venous-agreement
- tdm
2023
The authors validated a UHPLC-MS/MS method for quantifying four ceramide species in 10 μL quantitative dried blood spots. Ceramides remained stable at room temperature, supporting remote self-collection, and concentrations were higher in fingertip whole blood than in plasma or serum, which is relevant for at-home monitoring of cardiovascular and metabolic disease risk.
Ceramides biomarkers determination in quantitative dried blood spots by UHPLC-MS/MS — Meikopoulos et al., Analytica chimica acta (paywalled)
- blood
- dried
- capillary
- qdbs
- validation
- metabolome
- biomarkers
2023
Capillary blood in Hem-Col microtubes showed a relative bias of 1.23% against directly processed venous sampling for CEA, with samples remaining stable for up to four days after withdrawal. Home-based CEA monitoring for colorectal cancer follow-up is feasible with this method, though underfilled tubes flagged by high lithium concentrations yield less reliable results.
Reliable capillary sampling of carcinoembryonic antigen at home: the CASA feasibility study — Voigt et al., Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland (paywalled)
- blood
- liquid
- capillary
- self-collection
- validation
- venous-agreement
- colorectal
2023
Capillary blood self-collection showed acceptable agreement with venous samples for vitamin D, C-reactive protein and alkaline phosphatase even after 36-hour delays, but calcium and phosphate levels were more affected by pre-analytical conditions. This supports decentralised serology and biomarker testing while highlighting analytes that need tighter pre-analytical control.
Concordance in COVID-19 serology, bone mineralization, and inflammatory analytes between venous and self-collected capillary blood samples exposed to various pre-analytical conditions — Hosseini et al., Annals of clinical biochemistry (paywalled)
- blood
- liquid
- capillary
- validation
- venous-agreement
- serology
- biomarkers
2023
The study developed and validated an HPLC-DAD method for quantifying favipiravir in whole blood collected via VAMS, meeting FDA 2018 guidelines with a lower limit of quantification of 0.5 micrograms per millilitre. This supports the use of VAMS for therapeutic drug monitoring of favipiravir in decentralised settings.
HPLC-DAD quantification of favipiravir in whole blood after extraction from volumetric absorptive microsampling devices — Azzahra Rahmadhani et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
- blood
- dried
- vams
- neoteryx-mitra
- validation
- tdm
- antimicrobials
2023
The study found that VAMS dried blood sampling provides blood phenylalanine measurements highly concordant with venous plasma, with over 88% of results within 20% difference, supporting its use in patient-centric monitoring. This validates a decentralised, microsampling-based approach for therapeutic drug monitoring in phenylketonuria, including in children.
Validation and application of volumetric absorptive microsampling (VAMS) dried blood method for phenylalanine measurement in patients with phenylketonuria — Gao et al., Clinical biochemistry (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- venous-agreement
2023
Jacobs et al. validated a VAMS-based LC-HRMS/MS method for therapeutic drug monitoring of antihypertensive drugs in finger-prick blood, demonstrating acceptable accuracy and precision across haematocrit levels and stable analyte recovery for two weeks at ambient temperature. Whole-blood VAMS concentrations cannot be used interchangeably with plasma, requiring class-specific reference ranges, yet the approach is suitable for decentralised adherence assessment.
Closing the gap - development of an analytical methodology using volumetric absorptive microsampling of finger prick blood followed by LC-HRMS/MS for adherence monitoring of antihypertensive drugs — Jacobs et al., Analytical and bioanalytical chemistry
- blood
- dried
- vams
- validation
- tdm
- haematocrit
2023
Researchers developed and validated a UHPLC-MS/MS method for simultaneous quantification of favipiravir and remdesivir from VAMS blood samples, meeting FDA and EMA validation criteria. The method uses simple protein precipitation and supports therapeutic drug monitoring of COVID-19 antivirals in settings where small sample volumes and simplified processing are advantageous.
Development and validation of method for analysis of favipiravir and remdesivir in volumetric absorptive microsampling with ultra high-performance liquid chromatography-tandem mass spectrophotometry — Harahap et al., Frontiers in medicine
- blood
- dried
- vams
- validation
- tdm
- antimicrobials
2023
A qualitative study found that an online PrEP pathway incorporating postal self-sampling for HIV and STIs was highly acceptable to users and clinicians, offering convenience and service capacity benefits, though blood self-sampling was a barrier for some participants. The model suits established PrEP users with adequate digital literacy and requires integration with in-clinic support.
Delivering HIV prevention medication online: Findings from a qualitative study exploring the acceptability of an online HIV pre-exposure prophylaxis (PrEP) care pathway among service users and healthcare professionals — Kincaid et al., Digital health
- blood
- self-collection
- acceptability
- sti
2023
The study describes a protocol for measuring the low-abundance cancer biomarker progastrin-releasing peptide in dried serum spots and volumetric absorptive microsampling devices, finding that VAMS yielded higher signal intensities than dried serum spots.
Microsampling in Targeted Mass Spectrometry-Based Protein Analysis of Low-Abundance Proteins — Ngo et al., Journal of visualized experiments : JoVE (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- biomarkers
2023
In 20 women providing 73 paired samples across menstrual‑cycle phases, urinary metabolites measured at home correlated strongly with serum hormone concentrations (estradiol R²=0.96, progesterone R²=0.95, LH R²=0.98). When the derived equations were applied to a separate set of 20 users, predicted serum values correlated 0.92–0.94 with actual measurements. This suggests home urine testing could substitute for clinic blood draws in routine fertility monitoring, though the cohort was limited to women with normal cycles.
Predicting serum hormone concentration by estimation of urinary hormones through a home-use device — Pattnaik et al., Human reproduction open
- blood
- urine
- self-collection
- validation
- fertility
- hormones
2023
The TASSO-M20 device for self-collected capillary blood demonstrated strong agreement with liquid whole blood for phosphatidylethanol (PEth) measurement (r²=0.988) and proved feasible and acceptable during virtual alcohol monitoring, causing less discomfort than finger stick methods. In a single participant tracked over time, PEth levels from the device aligned with urinary ethyl glucuronide and self-reported alcohol consumption.
Validation of the quantification of phosphatidylethanol 16:0/18:1 concentrations in TASSO-M20 devices — Jett et al., Alcohol, clinical & experimental research (paywalled)
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
2023
Targeted DNA methylation analysis accurately estimated relative and absolute leukocyte subset counts from dried capillary blood collected with Mitra devices, showing strong correlation with conventional venous blood methods (r=0.72–0.97). This enables self-sampling by finger prick, facilitating easier access to leukocyte testing for patients with haematological disorders.
Targeted DNA Methylation Analysis Facilitates Leukocyte Counts in Dried Blood Samples — Hubens et al., Clinical chemistry (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- biomarkers
2023
In whole blood spiked with 90 drugs, the VAMS method using the Neoteryx Mitra device confirmed 87 compounds with identification limits below 12.5 ng/mL for 82.2% of drugs and extraction yields of 80.6 to 108.7%. In 15 poisoned patients, 98% of plasma compounds were detected in VAMS with satisfactory concordance (R2 = 0.827), supporting its use for decentralised toxicology screening.
New Trend in Toxicological Screening Using Volumetric Absorptive Microsampling (VAMS) and High-Resolution Mass Spectrometry (HR/MS) Combination — Houzé et al., Molecules
- blood
- dried
- vams
- neoteryx-mitra
- validation
- venous-agreement
- toxicology
2023
Female adolescent and young adult cancer survivors frequently misestimated their infertility risk, with minimal agreement between perceived risk and objective assessment using self-collected dried blood spots for ovarian reserve testing. The study suggests ongoing counselling could align perceptions with actual risk and inform family planning.
Perceived and Objective Fertility Risk Among Female Survivors of Adolescent and Young Adult Cancer — Din et al., JAMA network open
- blood
- dried
- dbs
- self-collection
- fertility
- hormones
2023
This protocol paper describes a decentralised HIV self-testing trial that enrolled 2093 Black and Hispanic men who have sex with men across 11 US states. The study incorporates laboratory analysis of participant-returned dried blood spot cards to verify self-reported HIV status, illustrating how patient-centric microsampling can be integrated into remote serology screening for underserved populations.
Engaging Black or African American and Hispanic or Latino Men Who Have Sex With Men for HIV Testing and Prevention Services Through Technology: Protocol for the iSTAMP Comparative Effectiveness Trial — Dana et al., JMIR research protocols
- blood
- dried
- dbs
- self-collection
- dct
- serology
- sti
2023
Self collected dried blood spots gave equivalent results to venous blood for lipids, HbA1c and C reactive protein, enabling similar classification of cardiovascular risk; self collection had lower response than nurse collection but similar demographic participation.
A randomised study of nurse collected venous blood and self-collected dried blood spots for the assessment of cardiovascular risk factors in the Understanding Society Innovation Panel — Kumari et al., Scientific reports
- blood
- dried
- dbs
- self-collection
- venous-agreement
- acceptability
- biomarkers
2023
Researchers validated a microsampling method for measuring baricitinib levels in children aged 2–18 years using the Mitra device. The approach showed good agreement with conventional plasma sampling and was well received by clinical sites, suggesting it could support paediatric therapeutic drug monitoring and trial enrolment.
Microsampling in pediatric studies: pharmacokinetic sampling for baricitinib (Olumiant™) in global pediatric studies — Wickremsinhe et al., Bioanalysis (paywalled)
- blood
- dried
- vams
- neoteryx-mitra
- validation
- pediatric
- tdm
2023
This review surveys published LC-MS/MS methods that use dried blood microsampling for therapeutic drug monitoring of immunosuppressants in transplantation, chemotherapy and autoimmune disease, finding that volumetric dried blood samples can replace conventional venous draws for home sampling and improve patient quality of life. The authors discuss pre-analytical considerations, clinical applicability, cost-effectiveness, harmonisation gaps and patient perception, concluding that obstacles to routine clinical implementation remain despite growing methodological maturity.
Dried blood microsampling-assisted therapeutic drug monitoring of immunosuppressants: An overview — Deprez & Stove, Journal of chromatography. A (paywalled)
- blood
- dried
- dbs
- volumetric
- validation
- acceptability
- tdm
- immunosuppressants
- economics
2023
The electrochemical sensor detected SARS-CoV-2 antibodies in under ten minutes from 1.5 μL patient samples with 100% sensitivity and specificity across 93 clinical specimens. Dried blood spots enabled self-collection and ambient-temperature transport, supporting remote serological surveillance and point-of-care assessment of humoral responses to vaccination or infection.
Rapid quantitation of SARS-CoV-2 antibodies in clinical samples with an electrochemical sensor — Timilsina et al., Biosensors & bioelectronics
- blood
- dried
- dbs
- validation
- serology
2023
In adult kidney transplant patients, fingerprick VAMS and dried blood spot microsampling achieved accurate simultaneous measurement of tacrolimus, mycophenolic acid, and prednisolone compared with venepuncture. The authors noted an overall preference for VAMS over conventional dried blood spots.
Fingerprick Microsampling Methods Can Replace Venepuncture for Simultaneous Therapeutic Drug Monitoring of Tacrolimus, Mycophenolic Acid, and Prednisolone Concentrations in Adult Kidney Transplant Patients — Scuderi et al., Therapeutic drug monitoring (paywalled)
- blood
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- immunosuppressants
2023
Microsampling assays for immunosuppressant monitoring showed three- to fourfold higher imprecision across 14 laboratories than conventional whole-blood analysis, with coefficients of variation of 11.7 to 18.6 percent versus 3.9 to 4.9 percent. In a patient specimen, this analytical scatter produced a different clinical decision, proving that current microsampling practice lacks the standardisation required for safe home-based therapeutic drug monitoring.
Results From a Proficiency Testing Pilot for Immunosuppressant Microsampling Assays — Veenhof et al., Therapeutic drug monitoring
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- tdm
- immunosuppressants
2023
The study developed and validated a UHPLC-MS/MS method to measure eight antibiotics in quantitative dried blood spots collected from neonates using a capillary microsampling device. This patient-centric approach enables robust pharmacokinetic monitoring in children where blood volume is limited, supporting decentralised therapeutic drug monitoring.
A Validated UHPLC-MS/MS Method to Quantify Eight Antibiotics in Quantitative Dried Blood Spots in Support of Pharmacokinetic Studies in Neonates — Liu et al., Antibiotics
- blood
- dried
- qdbs
- validation
- pediatric
- tdm
- antimicrobials
2023
Sexual minority men found finger-stick blood and rectal swabs more challenging to self-collect than other specimens. Barriers to returning samples included low confidence in self-collection and concerns about transit delays, while motivators were status confirmation and limited clinic access; real-time video support could improve uptake in future decentralised testing programmes.
Perceptions and Experiences of Returning Self-collected Specimens for HIV, Bacterial STI and Potential PrEP Adherence Testing among Sexual Minority Men in the United States — Sharma et al., AIDS and behavior
- blood
- urine
- self-collection
- acceptability
- serology
- sti
Read from the corpus on .