Skip to content
OpenSampling

The Library

1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.

Papers 201–300 of 323 labelled “venous-agreement”, newest first.

  1. 2022

    Neoteryx Mitra sticks and Noviplex cards agreed more closely with venous plasma and gave more repeatable N-glycoprofiling results than dried blood spots, with relative deviance from plasma of 0.092 and 0.069 respectively compared with 0.674 for dried blood spots, and coefficient of variation values of 7.098 per cent and 4.831 per cent against 14.305 per cent for dried blood spots. The findings support these self-sampling devices for decentralised glycoanalysis, though the authors call for larger cohort validation.

    Comparison of self-sampling blood collection for N-glycosylation analysisCvetko et al., BMC research notes

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
  2. 2022

    Dried blood spot sampling achieved high sensitivity and specificity for SARS-CoV-2 antibody detection with strong correlation to paired serum, enabling virtually painless, decentralised specimen collection in community and remote settings where venepuncture is difficult.

    Evaluation of serological assays for SARS-CoV-2 antibody testing from dried blood spots collected from cohorts with prior SARS-CoV-2 infectionCatlett et al., Journal of clinical virology plus

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  3. 2022

    A capture ELISA on dried blood spot eluates detected SARS-CoV-2 IgG and IgM with 97.9% sensitivity and 99.2% specificity compared with serum, showed strong correlation (r=0.81), and remained stable even when samples were deliberately rendered inadequate or accidentally damaged; all vaccine recipients were seropositive, supporting the use of DBS self-sampling for decentralised seroprevalence studies and post-vaccine response monitoring.

    Simple, sensitive, specific self-sampling assay secures SARS-CoV-2 antibody signals in sero-prevalence and post-vaccine studiesKhan et al., Scientific reports

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  4. 2022

    The authors validated an LC-MS and LC-MS/MS method for quantifying axitinib from 10 microlitre capillary blood collected by VAMS, demonstrating within- and between-run precision within 14% CV and accuracy between 81 and 116% against plasma as the gold standard, making the approach suitable for therapeutic drug monitoring in ambulatory and clinical care.

    Development and validation of a bioanalytical method for the quantification of axitinib from plasma and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MSOpitz et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • oncology
  5. 2022

    Capillary VAMS combined with direct mercury analysis demonstrated strong correlation with venous blood mercury concentrations in adult volunteers, with acceptable accuracy and precision above 1.0 µg/l. Storage in pre-cleaned glass vials following two hours of desiccator drying maintained analyte stability for at least four weeks.

    Mercury biomonitoring in German adults using volumetric absorptive microsamplingKoutsimpani-Wagner et al., Environmental monitoring and assessment

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • toxicology
  6. 2022

    The LC-MS/MS assay for uracil was validated with good accuracy and precision, and uracil concentrations measured in Tasso-SST capillary serum correlated highly with venous plasma (rs 0.910), indicating that capillary microsampling can reliably identify patients with DPD deficiency for safer fluoropyrimidine dosing.

    Evaluation of the Tasso-SST® capillary blood microsampling device for the measurement of endogenous uracil levelsMenestrina Dewes et al., Clinical biochemistry (paywalled)

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
    • oncology
  7. 2022

    Noninvasive salivary measurements of creatinine, cystatin C and urea, and fingerstick capillary blood testing, can approximate gold‑standard laboratory results for kidney function. This could enable more frequent, home‑based monitoring to detect CKD progression and AKI episodes without the burdens of conventional venepuncture and laboratory processing.

    Novel monitoring of renal function and medication levels in saliva and capillary blood of patients with kidney diseaseBeshay et al., Current opinion in nephrology and hypertension (paywalled)

    • blood
    • saliva
    • liquid
    • capillary
    • validation
    • venous-agreement
  8. 2022

    In a small substudy of psoriasis patients, lateral flow testing for adalimumab agreed very well with ELISA (r=0.95, R2=0.89) and capillary VAMS from finger prick correlated strongly with serum (r=0.87), while patients found home microsampling acceptable, indicating promise for decentralised TDM of biologics and warranting larger validation.

    Promising Tools to Facilitate the Implementation of TDM of Biologics in Clinical PracticeSoenen et al., Journal of clinical medicine

    • blood
    • dried
    • capillary
    • vams
    • self-collection
    • venous-agreement
    • acceptability
    • tdm
    • biologics
  9. 2022

    Finger-prick VAMS sampling gives results that agree well with venous blood for paracetamol and three of its four metabolites, offering a less burdensome method for pharmacokinetic studies in obese and non-obese patients. Concentrations of APAP-cysteine in dried blood require careful interpretation, as this metabolite showed the largest differences between capillary and venous samples.

    Application of a Volumetric Absorptive Microsampling (VAMS)-Based Method for the Determination of Paracetamol and Four of its Metabolites as a Tool for Pharmacokinetic Studies in Obese and Non-Obese PatientsBoffel et al., Clinical pharmacokinetics (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
  10. 2022

    A new LC-MS/MS method quantifies four immunosuppressants from one 3.2 mm dried blood spot using cold-induced phase separation, achieving accurate results and favourable interchangeability with a certified whole blood method in 120 paired clinical samples, supporting decentralised therapeutic drug monitoring.

    Quantification of immunosuppressants from one 3.2 mm dried blood spot by a novel cold-induced phase separation based LC-MS/MS methodLe et al., Analytica chimica acta (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  11. 2022

    Menstrual blood HbA1c levels showed strong concordance and a robust linear relationship with systemic venous HbA1c in both healthy and diabetic women, supporting its use as a non-invasive alternative for glycaemic monitoring.

    Novel use of menstrual blood for monitoring glycaemic control in patients with diabetes: a proof-of-concept studyNaseri et al., BMJ sexual & reproductive health (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
  12. 2022

    In a pilot study of 100 adults, 70 per cent collected an adequate capillary blood sample using the Tasso-SST device, and among those with an adequate sample results showed high concordance with routine phlebotomy for SARS-CoV-2 antibody testing, supporting the use of this self-collection system in decentralised diagnostics.

    Comparison of a Blood Self-Collection System with Routine Phlebotomy for SARS-CoV-2 Antibody TestingWixted et al., Diagnostics

    • blood
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
    • serology
  13. 2022

    Retrospective analysis of 15,218 paired samples from two paediatric centres showed capillary blood counts differ systematically from venous results, with haemoglobin 6.5 g/L higher and platelet count 7.01 × 10⁹/L lower on average. This large-scale evidence enables accurate interpretation of capillary samples in children, which is crucial for patient-centric microsampling in decentralised diagnostics.

    Differences between capillary and venous blood counts in children-A data mining approachBecker et al., International journal of laboratory hematology (paywalled)

    • blood
    • liquid
    • capillary
    • venous-agreement
    • pediatric
  14. 2022

    In a Ugandan cohort, 96% of participants successfully collected at least 16 of 24 requested at-home dried blood spots, with strong correlation (R=0.93) between parasite RNA detected in self-collected spots and venous blood. The method was well tolerated, indicating self-collected DBS can reliably support decentralised malaria surveillance in endemic settings.

    Feasibility of community at-home dried blood spot collection combined with pooled reverse transcription PCR as a viable and convenient method for malaria epidemiology studiesHergott et al., Malaria journal

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
    • pediatric
    • serology
  15. 2022

    Capillary blood self-sampling achieved 98.3% agreement with venous samples for SARS-CoV-2 IgG antibodies and 100% for IgA among 60 participants, demonstrating accuracy for vaccine monitoring. Saliva self-collection proved feasible with excellent usability, offering a patient-centric alternative for decentralised immunogenicity assessment.

    Self-collection of capillary blood and saliva to determine COVID-19 vaccine immunogenicity in patients with immune-mediated inflammatory diseases and health professionalsSchmetzer et al., Frontiers in public health

    • blood
    • saliva
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • serology
  16. 2022

    Dried blood spots collected by fingerprick at home produced SARS-CoV-2 antibody results comparable to plasma or serum in ELISA and commercial assays, reliably detecting responses months after infection and tracking post-vaccination kinetics in a community survey across 12 cities. This demonstrates that self-collected DBS enable longitudinal serosurveillance without phlebotomy, supporting their use in decentralised diagnostics when venous sampling is impractical.

    Development and Implementation of Dried Blood Spot-Based COVID-19 Serological Assays for Epidemiologic StudiesWong et al., Microbiology spectrum

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  17. 2022

    Capillary blood collected at home with the MiniCollect device showed good agreement with venous sampling for HbA1c analysis, supporting remote self-collection as a convenient alternative that maintains clinical performance and patient care during the COVID-19 pandemic.

    Remote capillary blood collection for HbA<sub>1c</sub> measurement during the COVID-19 pandemic: A laboratory and patient perspectiveGroenendijk et al., Diabetic medicine : a journal of the British Diabetic Association (paywalled)

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  18. 2022

    Self-collected dried blood spot samples showed 98.1% categorical agreement with venous serum and professional dried blood spot samples showed 100% agreement, enabling at-home serology with robust shipping stability and interference testing.

    Monitoring of SARS-CoV-2 antibodies using dried blood spot for at-home collectionMiesse et al., Scientific reports

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  19. 2022

    The study validated an LC-MS/MS method for measuring eight tyrosine kinase inhibitors in dried blood samples collected via VAMS, showing good accuracy, precision and haematocrit independence. It demonstrated agreement with venous sampling, supporting the use of decentralised, patient-centric microsampling for oncology drug monitoring.

    Volumetric absorptive microsampling as a suitable tool to monitor tyrosine kinase inhibitorsVerougstraete & Stove, Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • oncology
    • haematocrit
  20. 2022

    The Tasso SST capillary blood micro-sampling device generated reproducible serum protein measurements, but its concordance with venous samples was analyte-specific: CRP, ferritin, IL-6 and PCT showed strong agreement, while D-dimer, IL-1β and IL-1Ra did not. Self-collection at home with delayed processing led to significant concentration differences for several proteins, underscoring that user proficiency and timely sample handling are critical for decentralised diagnostic applications.

    Assessing the use of a micro-sampling device for measuring blood protein levels in healthy subjects and COVID-19 patientsBrandsma et al., PloS one

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • biomarkers
  21. 2022

    LC-MS/MS assay validation for monitoring tacrolimus and creatinine in renal transplant patients demonstrated that volumetric absorptive microsampling is the preferred single-sampling approach compared to traditional dried blood spots and venous sampling.

    Analytical and clinical validation of dried blood spot and volumetric absorptive microsampling for measurement of tacrolimus and creatinine after renal transplantationMathew et al., Clinical biochemistry (paywalled)

    • blood
    • dried
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  22. 2022

    The Tasso OnDemand device was well accepted by participants, with nearly all finding it easy to use and feeling confident they could self-sample at home, and paired self-collected and clinician-collected specimens showed high agreement for HIV, syphilis and creatinine tests. While most users collected enough serum for two monitoring tests, only a third produced sufficient volume for three tests, suggesting a larger-volume device may be preferable for full guideline-recommended PrEP monitoring.

    Feasibility of a novel self-collection method for blood samples and its acceptability for future home-based PrEP monitoringCannon et al., BMC infectious diseases

    • blood
    • liquid
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
    • serology
    • sti
  23. 2021

    Fingerstick plasma collected in Microtainer tubes showed 100% concordance with matched venous plasma on the Abbott ARCHITECT SARS-CoV-2 IgG assay, n=109. Fingerstick dried blood spots found high concordance with venous samples, n=61, supporting these microsampling methods for decentralised serology.

    Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assaysAnderson et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology

    • blood
    • liquid
    • capillary
    • dbs
    • bd-microtainer
    • validation
    • venous-agreement
    • serology
  24. 2021

    A study of 39 paediatric transplant recipients found capillary VAMS microsampling agreed closely with venous sampling for tacrolimus, with 92% of predose and 88% of postdose pairs within ±20% difference. Although sampling was performed in-clinic rather than at home, VAMS shows feasibility for patient-centric, decentralised monitoring.

    Tacrolimus Measured in Capillary Volumetric Microsamples in Pediatric Patients-A Cross-Validation StudyKindem et al., Therapeutic drug monitoring

    • blood
    • vams
    • validation
    • venous-agreement
    • pediatric
    • tdm
    • immunosuppressants
  25. 2021

    Capillary blood self‑collection with the Tasso‑SST device succeeded in over 93 % of attempts and produced SARS‑CoV‑2 IgG results that agreed closely with venous blood, maintaining 98.9 % overall accuracy after simulated summer and winter shipping. This supports reliable, decentralised serology testing without medical supervision.

    Self-collection of capillary blood using Tasso-SST devices for Anti-SARS-CoV-2 IgG antibody testingHendelman et al., PloS one

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • serology
  26. 2021

    A Simoa immunoassay detected SARS-CoV-2 nucleocapsid protein in venous and capillary blood and saliva with 98% negative and 90% positive agreement versus molecular testing across symptomatic, asymptomatic and pre‑symptomatic PCR‑positive individuals in days 1–7; N‑protein levels fell as spike‑IgG rose and correlated with saliva RT‑PCR Ct values and between matched saliva and capillary samples, enabling non‑invasive, swab‑independent sample collection for at‑home or point‑of‑care use.

    N-protein presents early in blood, dried blood and saliva during asymptomatic and symptomatic SARS-CoV-2 infectionShan et al., Nature communications

    • blood
    • saliva
    • liquid
    • capillary
    • validation
    • venous-agreement
    • serology
  27. 2021

    Capillary whole blood samples yielded comparable results to venous plasma for HbA1c, lipid profile and liver function tests after three days at ambient temperature, and a pilot home-collection kit was found to have good patient usability. This model could enable decentralised monitoring of chronic disease patients during virtual clinics, mitigating infection risk.

    The use of whole blood capillary samples to measure 15 analytes for a home-collect biochemistry service during the SARS-CoV-2 pandemic: A proposed model from North West London PathologyAnsari et al., Annals of clinical biochemistry

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  28. 2021

    Two home-use capillary blood collection kits for HbA1c measurement produced results within 5% of venous values for 96% to 99% of samples across different shipping conditions. The kits were easy to use and yielded comparable results to venous specimens for both paediatric and adult participants, supporting their use in decentralised clinical research and care.

    An Evaluation of Two Capillary Sample Collection Kits for Laboratory Measurement of HbA1cBeck et al., Diabetes technology & therapeutics (paywalled)

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • pediatric
  29. 2021

    In paediatric inflammatory bowel disease patients, infliximab levels measured from dried capillary blood spots strongly correlated with venous serum concentrations, with a mean difference of -0.14 μg/mL and excellent interclass correlation coefficient of 0.998. This demonstrates that finger-prick microsampling is a patient-friendly alternative to venepuncture for therapeutic drug monitoring of biologics in children.

    Infliximab Level Between Venous and Capillary Blood Using Novel Device Strongly Correlate in Paediatric Inflammatory Bowel Disease PatientsZijlstra et al., Journal of pediatric gastroenterology and nutrition (paywalled)

    • blood
    • dried
    • capillary
    • neoteryx-mitra
    • venous-agreement
    • pediatric
    • tdm
    • biologics
  30. 2021

    Dried blood spot specimens collected at home without medically trained personnel showed agreement with conventional venous blood when analysed by electrochemiluminescence immunoassay, with stable antibody readouts over more than 200 days of dry dark storage and consistent results in individuals tested twice within 10 months post-infection.

    Detection of anti-SARS-CoV-2 antibodies in dried blood spots utilizing manual or automated spot extraction and electrochemiluminescence immunoassay (ECLIA)Knoop et al., Analytical science advances

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  31. 2021

    Capillary dried blood spot samples analysed with the Roche Elecsys anti-SARS-CoV-2 assay on COBAS 6000 systems agreed with paired serum results in 98.9% of cases and remained accurate at 86.7% after 9 days, supporting their use for decentralised COVID-19 serosurveillance and large-scale screening.

    Analysis of SARS-CoV-2 antibodies from dried blood spot samples with the Roche Elecsys Immunochemistry methodFontaine & Saez, Practical laboratory medicine

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  32. 2021

    Dried capillary blood collected with volumetric absorptive microsampling provides linear agreement with serum for lamotrigine, lacosamide and levetiracetam, enabling conversion factors to estimate serum trough concentrations for therapeutic drug monitoring.

    Therapeutic Drug Monitoring of Lamotrigine, Lacosamide, and Levetiracetam in Dried Capillary Blood-Determination of Conversion Factors for Serum-Based Reference RangesKlimpel et al., Therapeutic drug monitoring (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
  33. 2021

    Volumetric absorptive microsampling (VAMS) achieved excellent correlation with conventional venous sampling for iohexol quantification and glomerular filtration rate (GFR) derivation in twenty children, showing minimal bias overall. Accuracy was lower for GFR values under 60 mL/min/1.73 m², but the method proved stable for 245 days and valid across a 20–60 % haematocrit range, offering a viable decentralised alternative for paediatric renal function assessment.

    Volumetric absorptive microsampling as alternative sampling technique for renal function assessment in the paediatric population using iohexolDhondt et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • pediatric
    • haematocrit
  34. 2021

    A quantitative dried blood spot device (Capitainer qDBS) combined with the Roche Elecsys anti-SARS-CoV-2 S immunoassay tracked anti-spike antibody development after two doses of the Pfizer vaccine, with the second dose producing a roughly hundredfold stimulation that peaked at two weeks and fell to 65 percent by three months. The bias between plasma and DBS was variable across both a 14-volunteer vaccination cohort and a 200-patient clinical cohort, yet DBS proved sufficiently sensitive for prolonged immune-status monitoring without venous draws.

    Use of Quantitative Dried Blood Spots to Evaluate the Post-Vaccination Level of Neutralizing Antibodies against SARS-CoV-2Marchand et al., Life

    • blood
    • dried
    • dbs
    • qdbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  35. 2021

    Capillary point-of-care haemoglobin measurement correlated strongly with venous automated complete blood count in adult dengue patients, though sensitivity for detecting haemoconcentration was only fair. Using capillary microsampling reduces venipuncture frequency, enabling more patient-centric decentralised monitoring of dengue.

    Comparison between blood hemoglobin concentration determined by point-of-care device and complete blood count in adult patients with dengueWisanuvej et al., PLoS neglected tropical diseases

    • blood
    • capillary
    • venous-agreement
    • haematocrit
  36. 2021

    The study developed and validated an LC-MS/MS method for moxidectin and showed that capillary Mitra® microsampling in Strongyloides-infected adults yielded pharmacokinetic profiles in close agreement with venous sampling, with identical time to maximal concentration of 4.0 hours and similar maximal concentrations of 83.9–88.5 ng/mL. This demonstrates the method and device are suitable for therapeutic drug monitoring of anthelmintics in decentralised field settings.

    Development and validation of an LC-MS/MS method for the quantification of the anthelmintic drug moxidectin in a volumetric absorptive microsample, blood, and plasma: Application to a pharmacokinetic study of adults infected with Strongyloides stercoralis in LaosHofmann et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
  37. 2021

    VAMS coupled with LC-MS/MS showed good correlation with conventional serum sampling for monoclonal antibody pharmacokinetics in rhesus monkeys, but a subsequent clinical study revealed that EDTA anticoagulant in standard and quality control samples caused anomalous internal standard responses in patient fingerstick samples, compromising accuracy. The authors recommend specific best practices during method development and validation to detect such anticoagulant effects early before deploying VAMS in clinical studies.

    Volumetric absorptive microsampling (VAMS®) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method developmentGao et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • biologics
  38. 2021

    The study compared VAMS capillary finger prick samples with venous liquid and venous VAMS samples from 50 healthy volunteers for thiamine diphosphate measurement, finding 94 to 100 per cent of results within 20 per cent of their mean across all comparisons with no significant bias. VAMS microsamples also remained stable when sent through regular post without affecting results, supporting their use for decentralised thiamine status assessment in both developed and remote settings.

    Volumetric absorptive microsampling (VAMS) as a reliable tool to assess thiamine status in dried blood microsamples: a comparative studyVerstraete & Stove, The American journal of clinical nutrition (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • dct
    • biomarkers
  39. 2021

    A VAMS method for 24 mycotoxins was validated against FDA and European Commission guidelines, showing no haematocrit bias and acceptable stability for 21 days at room temperature. Comparison with liquid whole blood from 20 samples revealed no missed exposed cases and comparable levels of key mycotoxins, supporting VAMS as an alternative to venous sampling in resource-limited settings.

    Volumetric Absorptive Microsampling as an Alternative Tool for Biomonitoring of Multi-Mycotoxin Exposure in Resource-Limited AreasVidal et al., Toxins

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • haematocrit
    • toxicology
  40. 2021

    Capillary blood collected by fingerstick with the Mitra volumetric absorptive microsampling device showed near identical sensitivity and specificity for SARS-CoV-2 antibodies compared with venous serum when analysed with the Roche Elecsys assay. This validation enables decentralised, patient-centric serology testing for remote or at-home use and large-scale community seroprevalence studies.

    Remote Fingerstick Blood Collection for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Antibody TestingGarcia-Beltran et al., Archives of pathology & laboratory medicine (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • self-collection
    • validation
    • venous-agreement
    • serology
  41. 2021

    Capillary blood collected by fingerstick showed near-perfect correlation with venous samples for HbA1c (R² = 0.993), with 96.7% of paired results differing by no more than 0.2%. Most participants found the kit easy to use at home, indicating potential for decentralised diabetes monitoring when in-person visits are impractical.

    Comparison of central laboratory HbA1c measurements obtained from a capillary collection versus a standard venous whole blood collection in the GRADE and EDIC studiesNathan et al., PloS one

    • blood
    • liquid
    • capillary
    • validation
    • venous-agreement
    • acceptability
    • dct
  42. 2021

    Capillary blood collected with the Neoteryx Mitra device showed a high correlation with venous samples for tacrolimus monitoring in transplant recipients, but yielded concentrations that were on average 22.5% higher. This minimally invasive method offers a convenient alternative to venepuncture for therapeutic drug monitoring, provided the consistent positive bias is accounted for in clinical interpretation.

    Validation of a Capillary Dry Blood Sample MITRA-Based Assay for the Quantitative Determination of Systemic Tacrolimus Concentrations in Transplant RecipientsUndre et al., Therapeutic drug monitoring

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  43. 2021

    Two feasibility studies assessed low-volume blood sampling for therapeutic drug monitoring. In patients receiving an anti-A therapeutic, drug levels were measured from finger-prick whole blood collected with Neoteryx Mitra and from capillary plasma collected with TASSO OnDemand, and compared with venipuncture samples. The work outlines practical considerations for adopting these patient-centric microsampling methods in decentralised trials and clinical care.

    Assessment of low volume sampling technologies: utility in nonclinical and clinical studiesWilliams et al., Bioanalysis (paywalled)

    • blood
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • biologics
  44. 2021

    Dried blood spots collected by fingerstick from SARS-CoV-2 convalescent and vaccinated individuals showed strong correlation with paired plasma for antibody binding and neutralisation titres. This supports decentralised serology by enabling self-collection and ambient-temperature mailing and storage, overcoming the cold-chain requirements of venous sampling.

    SARS-CoV-2 Antibody Binding and Neutralization in Dried Blood Spot Eluates and Paired PlasmaItell et al., Microbiology spectrum

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  45. 2021

    The HPLC-MS/MS assay on dried capillary blood collected with VAMS was linear, precise and stable, and showed strong agreement with liquid venous tacrolimus measurements, supporting its use for therapeutic drug monitoring in transplant recipients.

    Volumetric absorptive microsampling for the quantification of tacrolimus in capillary blood by high performance liquid chromatography-tandem mass spectrometryTron et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  46. 2021

    Dried blood spots collected by finger prick from nursing home residents and staff showed sensitivities of 95.0–97.1% and specificities of 97.1–98.8% against venous blood for SARS-CoV-2 IgG antibodies, demonstrating reliable performance even in elderly people with reduced cutaneous microvasculature. This supports decentralised serosurveillance and post-authorisation vaccine studies because DBS can be obtained remotely and stored at room temperature.

    Comparison of Dried Blood Spots and Venous Blood for the Detection of SARS-CoV-2 Antibodies in a Population of Nursing Home ResidentsMeyers et al., Microbiology spectrum

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • serology
  47. 2021

    Capillary blood self-sampling showed near-perfect agreement with venous sampling for SARS-CoV-2 IgG detection, achieving a Cohen's kappa of 0.88. Samples remained stable at room temperature for seven days, and 38 of 39 participants successfully collected adequate volumes, supporting its use for decentralised serological testing.

    Self-sampling of capillary blood for SARS-CoV-2 serologyBrown et al., Scientific reports

    • blood
    • liquid
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  48. 2021

    Self-sampled dried blood spots showed 99.20% sensitivity and 98.65% specificity for SARS-CoV-2 serology compared with venous sampling, and 99.87% of unsupervised home DBS cards were analysable, supporting DBS as a valid tool for large scale serosurveys and surveillance in resource limited settings.

    A dried blood spot protocol for high throughput analysis of SARS-CoV-2 serology based on the Roche Elecsys anti-N assayBeyerl et al., EBioMedicine

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  49. 2020

    In 33 patients, dried blood spots showed high correlation with venipuncture for adalimumab, Pearson ≥0.96, whereas home sampling showed moderate correlation with predicted concentrations, Pearson 0.51.

    Monitoring of Adalimumab Concentrations at Home in Patients with Inflammatory Bowel Disease Using Dried Blood SamplesBerends et al., Therapeutic Drug Monitoring (paywalled)

    • venous-agreement
    • biologics
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
  50. 2020

    The study found that HIV-1 viral load testing using fingerstick blood collected in BD Microtainer tubes showed high correlation, R² ≥0.980, with standard venous assays, supporting decentralised patient-centric microsampling. The authors note the limitation that testing was performed at a single laboratory site.

    Performance evaluation of the Aptima HIV-1 RNA Quant assay on the Panther system using the standard and dilution protocolsRossetti et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology (paywalled)

    • blood
    • liquid
    • capillary
    • bd-microtainer
    • venous-agreement
    • serology
  51. 2020

    Protein abundances measured by SomaScan were comparable between capillary samples collected with the TAP device and venous samples, and selected ELISA assays showed strong correlation, supporting the use of the TAP device for quantitative protein biomarker analysis in decentralised trials.

    Evaluation of a novel blood microsampling device for clinical trial sample collection and protein biomarker analysisXing et al., Bioanalysis (paywalled)

    • dct
    • venous-agreement
    • blood
    • capillary
    • yourbio
    • biomarkers
  52. 2020

    Fingerprick blood collected with Neoteryx Mitra devices showed minimal bias compared to venous sampling for tacrolimus (-5.6%) and creatinine (-6.5%) in renal transplant patients. This validated method could enable home-based therapeutic drug monitoring and kidney function testing, reducing the need for hospital visits.

    Assessment of tacrolimus and creatinine concentration collected using Mitra microsampling devicesMarshall et al., Annals of clinical biochemistry (paywalled)

    • blood
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  53. 2020

    Dried blood spots yield accurate HBV-DNA quantification comparable to plasma, with a limit of quantification of 400 IU/mL. The DNA remains stable in dried spots at room temperature for one month, offering a practical solution for remote hepatitis B monitoring in resource-limited settings to guide treatment and prevent mother-to-child transmission.

    Combined use of dried blood spot and rapid molecular systems: A robust solution to monitor hepatitis B virus infection with potential for resource-limited countriesBargain et al., Journal of virological methods (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • serology
  54. 2020

    The study validated dried blood spot cards for detecting rabies virus antibodies in 99 human pre- and post-vaccination samples, finding strong correlation between DBS and serum with the gold-standard FAVNt (R = 0.88) and acceptable sensitivity and specificity with both FAVNt and Platelia-II ELISA, supporting their use for rabies serology in remote areas where venipuncture is impractical.

    Dried blood spot cards: A reliable sampling method to detect human antibodies against rabies virusDoornekamp et al., PLoS neglected tropical diseases

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • serology
  55. 2020

    An LC-MS/MS assay for testosterone, androstenedione and 17-hydroxyprogesterone using Mitra microsampling devices achieved mean recoveries of 102%, 98% and 97% respectively, with limits of quantification of 1–4 nmol/L. This analytical validation demonstrates that volumetric absorptive microsampling can deliver reliable reproductive hormone measurements, supporting its use in decentralised diagnostics.

    Quantification of testosterone, androstenedione and 17-hydroxyprogesterone in whole blood collected using Mitra microsampling devicesMarshall et al., Annals of clinical biochemistry (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • fertility
    • hormones
  56. 2020

    Capillary blood collected by VAMS gave cannabidiol concentrations that agreed strongly with venous plasma (R² 0.93) in five paediatric and young adult patients with Dravet syndrome. This validates VAMS as a less invasive method for therapeutic drug monitoring of cannabidiol, enabling personalised therapy in refractory epilepsy within decentralised settings.

    A Volumetric Absorptive Microsampling Technique to Monitor Cannabidiol Levels in Epilepsy PatientsDubois et al., Frontiers in pharmacology

    • blood
    • dried
    • capillary
    • vams
    • venous-agreement
    • pediatric
    • tdm
  57. 2020

    The cobas® Plasma Separation Card demonstrated high sensitivity and specificity for HIV viral load from both venous and capillary blood, with misclassification rates under 1% compared with 5.9% for dried blood spots. This enables accurate decentralised HIV monitoring in primary care without requiring plasma centrifugation or cold chain transport.

    Accurate HIV viral load measurement in primary health care settings using the cobas® plasma separation cardVubil et al., PloS one

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • serology
  58. 2020

    Capillary blood collected with Neoteryx Mitra VAMS microsampling devices can quantify IGF-1 by automated chemiluminescent immunoassay after aqueous extraction. The hormone is stable for at least one month at room temperature, and dried blood concentrations match serum after dilution correction, though capillary samples underestimate high serum values, supporting patient-centric, decentralised endocrine monitoring but requiring population-specific reference ranges.

    Volumetric Absorptive Microsampling (VAMS) technology for IGF-1 quantification by automated chemiluminescent immunoassay in dried bloodMarchand et al., Growth hormone & IGF research : official journal of the Growth Hormone Research Society and the International IGF Research Society (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • hormones
  59. 2020

    This workshop report provides recommendations on blood sampling sites, bridging study design, and statistical methods for correlation to support the adoption of microsampling in patient-centric drug development. It emphasises the critical need for away-from-clinic sampling techniques to maintain patient safety during the COVID-19 pandemic.

    Land O'Lakes Workshop on Microsampling: Enabling Broader AdoptionWickremsinhe et al., The AAPS journal

    • blood
    • capillary
    • venous-agreement
    • acceptability
    • dct
    • standards
  60. 2020

    The study found reasonable agreement between finger-prick dried blood spot CRP measurements and venous reference assays in 100 rheumatoid arthritis patients, particularly at low to mid-range CRP values, and showed that weekly self-collected DBS CRP monitoring improved flare detection specificity to 72.7% compared with 54.5% for minimal sampling, supporting decentralised microsampling for remote arthritis management.

    Assessment of a dried blood spot C-reactive protein method to identify disease flares in rheumatoid arthritis patientsD'Cruz et al., Scientific reports

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • rpm
    • multimodal
  61. 2020

    Capiau et al. developed and validated a VAMS method for cobalt quantitation in whole blood from metal-on-metal prosthesis patients. The method proved accurate (bias ≤4%) and precise (RSD ≤5%), was unaffected by haematocrit, and showed a 0.99 correlation to liquid venous samples; 87% of results satisfied Royal College of Pathologists of Australasia criteria, enabling home-based monitoring of implant wear.

    Development, validation and application of an inductively coupled plasma - mass spectrometry method to determine cobalt in metal-on-metal prosthesis patients using volumetric absorptive microsamplingCapiau et al., Talanta (paywalled)

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • toxicology
  62. 2020

    Volumetric absorptive microsampling provides accurate quantification of 16 anti-epileptic drugs within two days of collection, showing less than ten percent deviation from conventional serum sampling and no haematocrit effect across the clinical range. This supports home-based therapeutic drug monitoring for epilepsy patients, though temperature-sensitive drugs require careful storage.

    Therapeutic drug monitoring of anti-epileptic drugs - a clinical verification of volumetric absorptive micro samplingCanisius et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • vams
    • validation
    • venous-agreement
    • tdm
    • haematocrit
  63. 2020

    The study developed and validated a LC-HRMS method for intact IGF-I from VAMS dried blood according to World Anti-Doping Agency requirements and showed agreement with serum measurements, supporting decentralised sampling for antidoping testing.

    Use of capillary dried blood for quantification of intact IGF-I by LC-HRMS for antidoping analysisMongongu et al., Bioanalysis (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • doping
  64. 2020

    Capillary blood sampling using volumetric absorptive microsampling demonstrated non-significant differences in cannabidiol concentrations compared to venous blood and plasma in pediatric patients treated with Epidiolex. The method requires 30 µL of sample, achieves linear quantification between 1 and 800 µg/L, and ensures analyte stability on VAMS devices for up to four weeks at room temperature.

    Cannabidiol Determination on Peripheral Capillary Blood Using a Microsampling Method and Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry with On-Line Sample PreparationPigliasco et al., Molecules

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • pediatric
    • tdm
  65. 2020

    The Mitra microsampling device showed high clinical concordance with venous blood for tacrolimus (89%) and cyclosporin A (98%) monitoring, with inter- and intra-precision within 11.5% CV and samples stable for up to 7 days at room temperature. Transplant patients preferred collecting capillary samples at home for their immunosuppressant monitoring, supporting decentralised TDM.

    Volumetric Microsampling of Capillary Blood Spot vs Whole Blood Sampling for Therapeutic Drug Monitoring of Tacrolimus and Cyclosporin A: Accuracy and Patient SatisfactionMbughuni et al., The journal of applied laboratory medicine (paywalled)

    • blood
    • capillary
    • vams
    • volumetric
    • neoteryx-mitra
    • validation
    • venous-agreement
    • acceptability
    • tdm
    • immunosuppressants
  66. 2020

    The study validated a VAMS-based bioanalytical method using the Tasso OnDemand device for the drug gefapixant and demonstrated a mathematical bridging relationship with standard plasma assays, supporting its use in decentralised clinical trials.

    Clinical application of volumetric absorptive microsampling to the gefapixant development programRoadcap et al., Bioanalysis (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
  67. 2020

    This review highlights how low-volume, minimally invasive microsampling of matrices such as dried capillary blood, interstitial fluid and saliva can enable untargeted metabolomics and longitudinal exposome studies in children, with the potential for home self-collection to improve convenience and parental support.

    Minimally Invasive Biospecimen Collection for Exposome Research in Children's HealthPetrick et al., Current environmental health reports (paywalled)

    • blood
    • saliva
    • interstitial-fluid
    • dried
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • pediatric
    • metabolome
  68. 2020

    Dried blood spot sampling using HemaSpot or Whatman903 cards demonstrated high analytical sensitivity for hepatitis B surface antigen, core antibody and hepatitis C antibody when compared with serum, with ratios ranging from 17.6:1 to 38.9:1. HemaSpot achieved 92.3% sensitivity and 100% specificity for HBsAg detection, maintained 80% detection efficacy after one month of storage, and showed no significant degradation after two weeks at ambient temperature, confirming its suitability for decentralised hepatitis screening in resource-limited settings.

    Evaluation of the efficiency of dried blood spot-based measurement of hepatitis B and hepatitis C virus seromarkersYamamoto et al., Scientific reports

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • serology
  69. 2020

    A GC-MS/MS method for anabolic steroids in VAMS dried blood from finger pricking demonstrated good precision, accuracy and stability, with results agreeing with serum specimens. In a testosterone gel administration trial, dried blood total testosterone identified transdermal micro-dosing, with concentrations rising up to ten times baseline at nine hours post-application, supporting decentralised doping screening.

    Determination of anabolic steroids in dried blood using microsampling and gas chromatography-tandem mass spectrometry: Application to a testosterone gel administration studyChang et al., Journal of chromatography. A (paywalled)

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • hormones
    • doping
  70. 2020

    Capillary microsampling using the Neoteryx Mitra device predicted tacrolimus AUC with high accuracy and precision compared with venous sampling in renal transplant recipients, with 85% of estimates within ±11.9% error. Patients could self-sample accurately at home, enabling patient-centred therapeutic drug monitoring without extended hospital stays.

    Tacrolimus Area Under the Concentration Versus Time Curve Monitoring, Using Home-Based Volumetric Absorptive Capillary MicrosamplingGustavsen et al., Therapeutic drug monitoring (paywalled)

    • blood
    • capillary
    • vams
    • neoteryx-mitra
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  71. 2020

    HbA1c measured from self-collected HemaSpot dried blood spots showed strong linear agreement with venous blood and was stable over time. With high patient acceptance, this supports remote diabetes monitoring for people in decentralised care models.

    HbA<sub>1c</sub> determination from HemaSpot™ blood collection devices: comparison of home prepared dried blood spots with standard venous blood analysisHall et al., Diabetic medicine : a journal of the British Diabetic Association

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  72. 2019

    A clinical validation showing dried blood samples can support infliximab concentration monitoring in inflammatory bowel disease.

    Dried blood samples can support monitoring of infliximab concentrations in patients with inflammatory bowel disease: A clinical validationBerends et al., British Journal of Clinical Pharmacology

    • venous-agreement
    • biologics
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • validation
  73. 2019

    Volumetric absorptive capillary microsampling gave reliable tacrolimus measurements throughout the dose interval in renal transplant recipients, with mean biases of -3.1% for mailed samples and -4.2% for direct delivery versus venous blood. Dried microsamples remained stable for one month at ambient temperature, enabling home-based therapeutic drug monitoring with postal shipment.

    Tacrolimus Can Be Reliably Measured With Volumetric Absorptive Capillary Microsampling Throughout the Dose Interval in Renal Transplant RecipientsVethe et al., Therapeutic drug monitoring (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  74. 2019

    Capillary citrate specimens from finger-stick correlated strongly with laboratory INR (r=0.97) and showed equivalence to venous sampling, with 89% of results within 0.5 INR units of agreement. This method avoids venepuncture trauma in paediatric patients while maintaining diagnostic accuracy for anticoagulation monitoring.

    Use of a capillary specimen in the laboratory to verify a point-of-care international normalized ratio: Avoidance of a venipuncture in a pediatric settingWilliams, International journal of laboratory hematology (paywalled)

    • blood
    • capillary
    • validation
    • venous-agreement
    • pediatric
  75. 2019

    Noviplex dried plasma spot cards yielded neurofilament light chain measurements equivalent to standard plasma in healthy controls and ALS patients, while dried blood spot eluates gave different absolute values but still discriminated between the two groups. The results support remote dried blood microsampling as a practical alternative to venous sampling for neurodegeneration biomarkers in ALS.

    Theme 7 Pre-clinical therapeutic strategiesLombardi et al., Amyotrophic lateral sclerosis & frontotemporal degeneration (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • biomarkers
  76. 2019

    Dried blood spot viral load quantification using the Biocentric method correlated with plasma testing (r=0.67–0.82) and delivered comparable diagnostic accuracy at the 1000 copies/mL threshold across three collection methods. This validates patient-centric microsampling for decentralised HIV monitoring in resource-limited settings.

    Field Suitability and Diagnostic Accuracy of the Biocentric Open Real-Time PCR Platform for Dried Blood Spot-Based HIV Viral Load Quantification in EswatiniKerschberger et al., Journal of acquired immune deficiency syndromes

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • serology
  77. 2019

    A systematic review of dried blood spot sampling for tacrolimus monitoring across adult and paediatric organ transplant recipients demonstrated that reported analytical bias compared with venous sampling fell within acceptable limits across the majority of studies. This supports dried blood microsampling as an accurate approach for decentralised therapeutic drug monitoring.

    Predictability of Capillary Blood Spot Toward Venous Whole Blood Sampling for Therapeutic Drug Monitoring of Tacrolimus in Solid Organ Transplant RecipientsGallant et al., European journal of drug metabolism and pharmacokinetics (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • pediatric
    • tdm
    • immunosuppressants
  78. 2019

    HPLC-MS/MS methods for midazolam and 1-OH midazolam in wet whole blood and dried blood collected on VAMS were developed and validated, meeting international guideline criteria; a strong correlation between wet and dry concentrations was observed, indicating VAMS is suitable for paediatric clinical studies.

    Validation of methods for determining pediatric midazolam using wet whole blood and volumetric absorptive microsamplingAbu-Rabie et al., Bioanalysis (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • pediatric
    • tdm
  79. 2019

    Matched fingerstick capillary blood samples showed near-perfect agreement with venipuncture across anti-müllerian hormone, estradiol, FSH, LH, prolactin, testosterone, TSH and free T4, with correlations of 0.99–1.00 and minimal bias, supporting interchangeable use and enabling virtually painless at-home testing for fertility hormone assessment.

    Concordance of Fingerstick and Venipuncture Sampling for Fertility HormonesBurke et al., Obstetrics and gynecology (paywalled)

    • blood
    • capillary
    • validation
    • venous-agreement
    • fertility
    • hormones
  80. 2019

    Volumetric absorptive microsampling (VAMS) using the Neoteryx Mitra device was validated for mitotane therapeutic drug monitoring across 1–50 mg/L, with acceptable haematocrit bias and one-week stability at room temperature. However, comparison with venous plasma showed poor correlation, suggesting home-based VAMS is of limited clinical value for mitotane unless a method-specific target range is established.

    A method for the minimally invasive drug monitoring of mitotane by means of volumetric absorptive microsampling for a home-based therapeutic drug monitoringFriedl et al., Analytical and bioanalytical chemistry (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • oncology
  81. 2019

    Guardian-collected capillary dried blood spots were feasible for home monitoring of lamotrigine, and for carbamazepine and valproic acid when conversion factors were applied, with only 4 of 190 comparisons risking a conflicting dose decision and negligible risk of patient harm. Levetiracetam DBS showed high variability against plasma and is recommended only for checking nonadherence, not for dose adjustment.

    Dried Blood Spot Self-Sampling by Guardians of Children With Epilepsy Is Feasible: Comparison With Plasma for Multiple Antiepileptic DrugsLinder et al., Therapeutic drug monitoring (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • pediatric
    • tdm
  82. 2019

    Microsampling with the Neoteryx Mitra device showed acceptable linearity and precision for cyclosporine A, everolimus, sirolimus and tacrolimus, and agreed closely with conventional venous extraction by Deming regression, supporting its use for decentralised immunosuppressant therapeutic drug monitoring.

    Feasibility of Immunosuppressant Drug Monitoring by a Microsampling DeviceGruzdys et al., The journal of applied laboratory medicine (paywalled)

    • blood
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  83. 2019

    In ten healthy volunteers, radiprodil pharmacokinetics measured by Aqua-Cap™ Drummond microsampling closely matched conventional venous blood draws, whereas Mitra™ microsampling gave marginally lower exposure values. Both microsampling methods fell within the accepted bioequivalence range, indicating they could enable patient-centric therapeutic drug monitoring and future paediatric decentralised trials.

    A pharmacokinetic study of radiprodil oral suspension in healthy adults comparing conventional venous blood sampling with two microsampling techniquesSciberras et al., Pharmacology research & perspectives

    • blood
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • pediatric
  84. 2019

    Finger prick dried blood spots correlated strongly with venous whole blood for poly- and perfluoroalkyl substances, achieving Spearman coefficients between 0.72 and 0.97. The method requires only 30 μL of blood, enabling decentralised biomonitoring of environmental toxins with minimal burden.

    Dried blood spots for reliable biomonitoring of poly- and perfluoroalkyl substances (PFASs)Poothong et al., The Science of the total environment (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • toxicology
  85. 2019

    This study demonstrates for the first time that HPV vaccine antibodies can be detected in first-void urine from young women, with levels correlating strongly to serum (Spearman r 0.64–0.88). This non-invasive approach could support large-scale epidemiological studies and vaccine monitoring, reducing the need for venous blood draws, though further optimisation and validation is needed.

    First-void urine as a non-invasive liquid biopsy source to detect vaccine-induced human papillomavirus antibodies originating from cervicovaginal secretionsVan Keer et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology (paywalled)

    • urine
    • first-void
    • validation
    • venous-agreement
    • serology
    • hpv
  86. 2019

    VAMS capillary blood showed strong agreement with venous serum for measuring anti-influenza antibodies and remained stable for three weeks at room temperature. When volunteers performed finger-stick sampling at home, their results were highly consistent with on-site collection by study personnel.

    Application of volumetric absorptive microsampling (VAMS) to measure multidimensional anti-influenza IgG antibodies by the mPlex-Flu assayWang et al., Journal of clinical and translational science

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • self-collection
    • validation
    • venous-agreement
    • serology
  87. 2019

    Fingerprick dried blood spots showed analytical agreement with whole blood for sirolimus and everolimus in transplant patients, but only 77.3% and 61.5% of samples fell within the pre-defined 15% clinical relevance limit, missing the 80% target for both drugs. This suggests the method cannot yet replace conventional sampling for immunosuppressant monitoring without accepting less stringent clinical criteria, which constrains its use in decentralised diagnostics.

    Clinical application of a dried blood spot assay for sirolimus and everolimus in transplant patientsVeenhof et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  88. 2019

    The validated LC-MS/MS method showed similar pharmacokinetic profiles for albendazole and its metabolites across plasma, whole blood, dried blood spots and Mitra microsamples from hookworm-infected adolescents, supporting microsampling for paediatric pharmacokinetic studies. Mitra extraction proved more robust than dried blood spots during validation and is recommended for future albendazole pharmacokinetic work, despite higher albendazole sulfone concentrations observed in both microsampling devices compared with wet matrices.

    Pharmacokinetics of Albendazole, Albendazole Sulfoxide, and Albendazole Sulfone Determined from Plasma, Blood, Dried-Blood Spots, and Mitra Samples of Hookworm-Infected AdolescentsSchulz et al., Antimicrobial agents and chemotherapy (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
    • pediatric
    • tdm
    • antimicrobials
  89. 2018

    Metabolomics of TAP capillary blood matched venous draws for most metabolites, amino acids, bile acids and acyl-carnitines at r≥0.95; a small redox/energy subset differed with collection dynamics.

    Quantitative metabolomics comparison of traditional blood draws and TAP capillary blood collectionCatala et al., Metabolomics (paywalled)

    • venous-agreement
    • blood
    • metabolome
    • capillary
    • liquid
    • yourbio
    • validation
  90. 2018

    Telomere length measurements vary significantly depending on the sample type used, with Oragene saliva showing a moderate correlation to venous buffy coat, whereas Oasis saliva and dried blood spots did not yield comparable or adequate results for this assay.

    Evaluating minimally invasive sample collection methods for telomere length measurementGoldman et al., American journal of human biology : the official journal of the Human Biology Council (paywalled)

    • blood
    • saliva
    • dried
    • dbs
    • dna-genotek-oragene
    • validation
    • venous-agreement
    • genotyping
  91. 2018

    Volumetric dried blood spot sampling showed good agreement with conventional venous sampling for tacrolimus and mycophenolic acid concentrations in renal transplant recipients, with most concentrations and abbreviated AUCs falling within ±20% of conventional measures. Dosing recommendations differed on some occasions but the clinical impact was modest, suggesting home-based microsampling could support decentralised therapeutic drug monitoring with appropriate patient training.

    Therapeutic drug monitoring of tacrolimus and mycophenolic acid in outpatient renal transplant recipients using a volumetric dried blood spot sampling deviceZwart et al., British journal of clinical pharmacology (paywalled)

    • blood
    • dried
    • dbs
    • volumetric
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  92. 2018

    The study found substantial agreement between serum tobramycin and vancomycin concentrations collected from existing peripheral or central venous catheters and those obtained by venipuncture or fingerstick in pediatric patients. This suggests that using a strict flush and waste protocol allows for therapeutic drug monitoring without additional painful needle sticks, thereby improving patient satisfaction.

    Therapeutic antibiotic serum concentrations by two blood collection methods within the pediatric patient: A comparative effectiveness trialLichliter et al., Journal for specialists in pediatric nursing : JSPN (paywalled)

    • blood
    • liquid
    • capillary
    • venous-agreement
    • pediatric
    • tdm
    • antimicrobials
  93. 2018

    Glycated haemoglobin measurement from home-collected dried blood spots correlated strongly with venous sampling (r=0.93) and, after bias correction, achieved a concordance correlation of 0.9 with 100% positive predictive value for levels above 7%. With 88.5% of patients preferring home collection, the method offers a viable patient-centric alternative to laboratory venepuncture for decentralised diabetes monitoring.

    Comparison of Glycated Hemoglobin Results Based on At-Home and In-Lab Dried Blood Spot Sampling to Routine Venous Blood Sampling In-Lab in Adult Patients With Type 1 or Type 2 DiabetesElliott et al., Canadian journal of diabetes (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  94. 2018

    The authors validated a dried blood spot assay for benznidazole that showed strong agreement with plasma concentrations (r²=0.8295) and proved stable at room temperature for more than one year. This microsampling approach enables therapeutic drug monitoring for Chagas disease in decentralised trials and remote settings, including paediatric populations.

    Dried Blood Spot Technique-Based Liquid Chromatography-Tandem Mass Spectrometry Method as a Simple Alternative for Benznidazole Pharmacokinetic AssessmentGalindo Bedor et al., Antimicrobial agents and chemotherapy

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • haematocrit
  95. 2018

    The optimised Abbott DBS protocol for HIV RNA testing performed well in a Vietnamese routine clinical setting, meeting WHO performance criteria for viral load monitoring. This supports scaling up decentralised HIV care, though sensitivity at the 1000 copies/mL threshold remains a challenge to avoid keeping patients on failing antiretroviral therapy.

    First field evaluation of the optimized CE marked Abbott protocol for HIV RNA testing on dried blood spot in a routine clinical setting in VietnamTaieb et al., PloS one

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • serology
  96. 2018

    Capillary C-peptide concentrations measured from dried blood spot and volumetric absorptive microsampling showed strong agreement with reference plasma samples. Both sampling methods maintained stability over 48 hours at room temperature, supporting their utility for remote monitoring of endogenous insulin secretion.

    Microsampling Collection Methods for Measurement of C-peptide in Whole BloodJones et al., Journal of diabetes science and technology (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
  97. 2018

    Dried blood spot sampling showed good agreement with whole blood for measuring everolimus in cancer patients, with ninety percent of samples demonstrating acceptable prediction error and low bias. This enables home-based therapeutic drug monitoring, allowing clinicians to individualise dosing without requiring patient visits.

    Clinical validation study of dried blood spot for determining everolimus concentration in patients with cancerWillemsen et al., European journal of clinical pharmacology

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • oncology
  98. 2018

    A dried blood spot LC-MS/MS method was validated for therapeutic monitoring of carbamazepine, lamotrigine, levetiracetam and valproic acid. Concentrations from dried blood spots correlated strongly with plasma (R² 0.92) across venous and capillary samples, enabling home self-collection and reducing clinic visits for children with epilepsy.

    Carbamazepine, lamotrigine, levetiracetam and valproic acid in dried blood spots with liquid chromatography tandem mass spectrometry; method development and validationLinder et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • pediatric
    • tdm
  99. 2017

    Finger-prick dried blood spots supported monitoring of both adalimumab and anti-adalimumab antibodies in inflammatory rheumatic disease: biologic TDM without a venous draw.

    Dried blood spots from finger prick facilitate therapeutic drug monitoring of adalimumab and anti-adalimumab in patients with inflammatory rheumatic diseasesKneepkens et al., British Journal of Clinical Pharmacology (paywalled)

    • venous-agreement
    • biologics
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • validation
  100. 2017

    VAMS microsampling of capillary blood provided accurate measurement of hydroxychloroquine and metabolites in rheumatoid arthritis patients, with results agreeing with venous blood while overcoming dried blood spot limitations of haematocrit bias and inhomogeneity, and offered potential for home self-collection.

    Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patientsQu et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • validation
    • venous-agreement
    • tdm

Read from the corpus on .