Skip to content
OpenSampling

The Library

1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.

Papers 101–200 of 541 labelled “dried”, newest first.

  1. 2025

    The study compared quantitative dried blood spot (qDBS) and volumetric absorptive microsampling (VAMS) devices for measuring ganciclovir levels in capillary blood from pediatric renal transplant recipients. This comparison provides evidence for choosing between microsampling devices in therapeutic drug monitoring, supporting decentralised sampling approaches that reduce patient burden while maintaining analytical accuracy.

    The comparison of two volumetric microsampling devices (qDBS and VAMS) for determining ganciclovir levels in capillary blood using the LC-MS/MS technique in pediatric renal transplant recipientsKocur et al., European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences (paywalled)

    • vams
    • volumetric
    • blood
    • qdbs
    • tdm
    • dried
    • antimicrobials
    • capillary
    • pediatric
    • validation
  2. 2025

    This review summarises how volumetric absorptive microsampling facilitates self-sampling and improves stability for pharmacokinetic and toxicokinetic studies while maintaining performance comparable to standard venous blood draws.

    How microsampling is impacting pharmacokinetic and toxicokinetic studies: volumetric absorptive microsampling (VAMS)Protti et al., Bioanalysis (paywalled)

    • vams
    • blood
    • dried
    • toxicology
    • validation
  3. 2025

    A UHPLC-MS/MS assay using the Capitainer-qDBS device successfully quantified five antiseizure medications, showing robust 30-day stability at room temperature and no haematocrit effect between 20-70%. Although the clinical cohort was small, comparison with plasma in 30 patients showed good correlation, supporting the potential of this patient-centric microsampling method for decentralised home monitoring.

    Quantitative dried blood spot microsampling for therapeutic drug monitoring of -antiseizure medications by design of experiment and UHPLC-MS/MSCancellerini et al., Talanta (paywalled)

    • venous-agreement
    • blood
    • qdbs
    • tdm
    • haematocrit
    • dried
    • validation
  4. 2025

    A study of 12 kidney transplant recipients providing 69 paired samples found that a VAMS-based assay for mycophenolic acid and its metabolite had 90% to 106% accuracy. Converting microsampling results to plasma concentrations met agreement criteria, supporting decentralised monitoring, though the study was small and limited to a single centre.

    Development and Clinical Validation of a Volumetric Absorptive Capillary Microsampling Method for Quantification of Mycophenolic Acid and Mycophenolic Acid Glucuronide in Kidney Transplant RecipientsDrevland et al., Therapeutic drug monitoring (paywalled)

    • vams
    • venous-agreement
    • blood
    • tdm
    • dried
    • capillary
    • immunosuppressants
    • validation
  5. 2025

    A study of older rural US patients found that 96 to 98 per cent of self-collected dried blood spot specimens were successfully analysed for HIV viral load, with high acceptability. However, concordance between self-reported and measured viral load was only 69 to 82 per cent, highlighting the value of objective decentralised microsampling over self-reporting.

    Acceptability and Feasibility of Self-Collected Dried Blood Spot Specimens for Viral Load Monitoring among Rural Older People Living with HIVWalsh et al., AIDS and behavior (paywalled)

    • dct
    • acceptability
    • blood
    • dbs
    • self-collection
    • dried
    • serology
  6. 2025

    A validated LC-MS/MS method for everolimus using Mitra and Capitainer devices found excellent agreement between capillary microsamples and venous whole blood in 33 adult transplant recipients. The results showed high accuracy and negligible haematocrit effects, supporting the use of microsampling for decentralised therapeutic drug monitoring.

    Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative StudyKocur et al., Molecules

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • qdbs
    • tdm
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
    • validation
  7. 2025

    In children with SLE, VAMS finger-prick capillary blood gave haematocrit-adjusted MPA and MPAG concentrations indistinguishable from plasma, and the AUC from VAMS derived plasma-equivalent concentrations matched plasma AUC with R2 0.97. This supports accurate pharmacokinetically guided dosing of MMF using only three timed capillary microsamples.

    Volumetric Absorptive Microsampling Combined with Mass Spectrometry to Support Pharmacokinetically-Guided Precision Dosing of Mycophenolate Mofetil in Pediatric Lupus Nephritis PatientsZhao et al., The journal of applied laboratory medicine (paywalled)

    • vams
    • venous-agreement
    • blood
    • tdm
    • haematocrit
    • dried
    • capillary
    • pediatric
    • immunosuppressants
    • validation
  8. 2025

    A study of 292 patients found that the slopes of home-collected stimulated dried blood spot C-peptide levels over six months predicted 12-month venous mixed-meal tolerance test results, P<0.001. This shows decentralised microsampling can monitor beta-cell function, though further validation is required to confirm its reliability and broader applicability.

    Early Detection of β-Cell Decline Using Home Dried Blood Spot C-Peptide Levels in New-Onset Type 1 DiabetesHendriks et al., Diabetes care (paywalled)

    • dct
    • venous-agreement
    • blood
    • dbs
    • self-collection
    • dried
    • pediatric
    • biomarkers
  9. 2025

    A validated offline SPE-LC-MS/MS method using the Mitra microsampling device successfully quantified tacrolimus, cyclosporine A, tryptophan, kynurenine, and creatinine simultaneously. The method met EMA and FDA criteria, showing agreement between capillary and venous sampling, which could facilitate decentralised therapeutic drug monitoring and transplant follow-up through patient self-collection.

    An Offline SPE-LC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Cyclosporine A, Kynurenine, Tryptophan, and Creatinine Using Volumetric Absorptive Microsampling Device MitraNierychlewski et al., Therapeutic drug monitoring

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • immunosuppressants
    • biomarkers
  10. 2025

    The authors found that a single microdose of recombinant EPO was detectable up to 72 hours using ITP and CP methods, though the Tasso microsampling device showed lower sensitivity than Mitra and Capitainer. Additionally, isotope ratio mass spectrometry successfully detected testosterone micro-dosing in all analysed samples, supported by serum testosterone levels.

    Detection of a Single Microdose of Testosterone and Recombinant EPO in Healthy VolunteersHeiland et al., Drug testing and analysis

    • neoteryx-mitra
    • doping
    • blood
    • dbs
    • dried
    • steroids
    • capillary
    • hormones
    • urine
    • validation
  11. 2025

    Microsampling, particularly VAMS and quantitative DBS, can enable patient-centric therapeutic drug monitoring of immunosuppressants after transplantation, allowing home self-sampling and long-term monitoring when patients live far from transplant centres. These volumetric dried formats have largely overcome the haematocrit effect and sample heterogeneity that limit conventional dried blood spots.

    Microsampling techniques and patient-centric therapeutic drug monitoring of immunosuppressantsKocur & Pawiński, Bioanalysis (paywalled)

    • vams
    • venous-agreement
    • blood
    • qdbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
  12. 2025

    In an untargeted metabolomics study, microsampling devices, particularly the Mitra and Capitainer, yielded metabolic profiles comparable or superior to plasma in feature number and intensity, and in the precision and stability of some metabolites. This supports their potential for large-scale, decentralised metabolic profiling, though the captured metabolite profile was application-dependent.

    LC-MS-Based Global Metabolic Profiles of Alternative Blood Specimens Collected by MicrosamplingThaitumu et al., Metabolites

    • vams
    • neoteryx-mitra
    • blood
    • dbs
    • qdbs
    • metabolome
    • dried
    • validation
    • biomarkers
  13. 2025

    This study found that stool samples self-collected on cards showed high correlation and agreement with ethanol-fixed samples for metagenomic sequencing, with negligible differences in microbial diversity. The results support the use of stool cards as a cost-effective alternative for decentralised sampling in epidemiologic studies, despite minor variations in individual species abundance.

    Comparing the Metagenomic Performance of Stools Collected from Custom Cards and 95% Ethanol in Epidemiologic StudiesKuntz et al., Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology (paywalled)

    • stool
    • dried
    • self-collection
    • validation
    • microbiome
    • colorectal
  14. 2025

    This study validated a method combining quantitative dried blood spots with DNA methylation analysis to monitor B-cell counts remotely, achieving 100% sensitivity and specificity for a specific clinical threshold. This decentralised approach facilitates patient-centric therapeutic drug monitoring for anti-CD20 therapies by overcoming the logistical barriers of regular venous sampling.

    Home-sampling of B cells using quantitative dried blood spots to enable tailored therapeutic re-dosing of anti-CD20 therapiesTallantyre et al., Multiple sclerosis (paywalled)

    • biologics
    • multimodal
    • blood
    • rpm
    • qdbs
    • tdm
    • self-collection
    • dried
    • validation
  15. 2025

    This study compared OMNIgene Gut tubes and FTA cards for stool collection in a deployed setting, finding that OMNIgene yielded higher nucleic acid concentrations while both methods detected the majority of microbial genera. The authors conclude that distinct microbial abundance profiles between the two methods necessitate standardised protocols for field research.

    Field expedient stool collection methods for gut microbiome analysis in deployed military environmentsKok et al., mSphere

    • stabilised
    • dna-genotek-omnigene
    • dried
    • microbiome
    • stool
    • validation
  16. 2025

    This study found that dried blood microsamples, particularly those collected with the Mitra device, provided metabolic profiles comparable or superior to conventional plasma, supporting their use as a viable alternative for untargeted metabolomics.

    Toward minimally invasive metabolomics: GC-MS metabolic fingerprints of dried blood microsamples in comparison to plasmaMarques de Sá E Silva et al., The Analyst (paywalled)

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • metabolome
    • dried
    • capillary
    • validation
  17. 2025

    Capillary dried blood spot concentrations of levetiracetam agreed closely with plasma, with 92.1% within 20% of the mean and no proportional bias, and capillary matched venous dried blood spot with acceptable deviations; samples remained stable during postal transit, enabling at‑home self‑sampling for therapeutic drug monitoring.

    Therapeutic drug monitoring of levetiracetam - Is dried blood spot sampling suitable?Linder et al., Clinical biochemistry (paywalled)

    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
    • validation
  18. 2025

    A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.

    Patient centric blood sampling and analysis for diagnostics and laboratory medicineSpooner et al., Bioanalysis

    • blood
    • standards
    • self-collection
    • haematocrit
    • dried
    • capillary
    • liquid
    • validation
  19. 2025

    In 40 participants, dried blood spots showed excellent agreement with venous blood for HBA1c measurement (LCCC 0.982, PCC 0.990, limits of agreement -0.45 to 0.48). The method demonstrated high repeatability (CV 1.13) and clinical conformity (K 0.80), suggesting capillary DBS sampling could replace venipuncture for diabetes monitoring in decentralised settings.

    Preliminary comparative study of HBA1c measurement by IEX-HPLC Bio-Rad in dried blood spot vs. whole venous bloodHadami et al., Annales de biologie clinique (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • venous-agreement
    • acceptability
  20. 2025

    A newborn screening programme using dried blood spots detected classic 21-hydroxylase deficiency in 1 in 17,699 infants, with second-tier LC-MS/MS testing achieving a positive predictive value of 4.3. However, 23% of cases became symptomatic before results were reported, highlighting that timeliness remains a critical challenge for decentralised diagnostics.

    Newborn screening for congenital adrenal hyperplasia due to 21 hydroxylase deficiency: the Italian experience 2006-2019Baronio et al., Journal of endocrinological investigation (paywalled)

    • blood
    • dried
    • dbs
    • pediatric
    • hormones
  21. 2025

    Among staff in long-term care and retirement homes in Ontario, SARS-CoV-2 seroprevalence rose from 24% in 2021 to 44% in 2022 and was higher in Black, East and Southeast Asian and other racialised groups, lower in higher income neighbourhoods and among those with paid sick leave, indicating socioeconomic disparities that should inform equity rooted public health interventions.

    Patterns of SARS-CoV-2 seropositivity among essential workers in long term care and retirement homes in Ontario, Canada: A descriptive cross-sectional studyFahim et al., PLOS global public health

    • blood
    • dried
    • dbs
    • self-collection
    • serology
  22. 2025

    A term newborn died at 4 days; newborn screening by tandem mass spectrometry on a dried blood spot indicated mitochondrial trifunctional protein or long-chain 3-hydroxyacyl-CoA dehydrogenase deficiency, and genetic analysis of the same DBS identified two HADHA variants, confirming the diagnosis; the authors review early neonatal deaths from fatty acid oxidation disorders and discuss limitations of newborn screening for these conditions, highlighting the role of DBS-based screening and post-mortem genetic testing in decentralised diagnostics.

    Sudden Death of a Four-Day-Old Newborn Due to Mitochondrial Trifunctional Protein/Long-Chain 3-Hydroxyacyl-CoA Dehydrogenase Deficiencies and a Systematic Literature Review of Early Deaths of Neonates with Fatty Acid Oxidation DisordersDrole Torkar et al., International journal of neonatal screening

    • blood
    • dried
    • dbs
    • pediatric
  23. 2025

    Dried blood spot HPLC accurately identified and quantified all major hemoglobin variants after ambient storage for up to three weeks, correctly diagnosing sickle cell, beta-thalassemia and other hemoglobinopathies compared to conventional whole blood analysis. This supports cost-effective, decentralised screening in remote regions where venous sampling is impractical.

    Hemoglobin Variant Analysis and Its Comparison between Conventional High-performance Liquid Chromatography Using Whole Blood versus Dried Blood Spot: High-performance Liquid ChromatographyJena et al., Indian journal of public health (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • economics
  24. 2025

    In a prospective study of 126 people who inject drugs, 44 percent completed DBS self-collection and received HCV results; among completers, 7 percent had detectable HCV RNA and all initiated treatment. Completion was higher in those aged 40 or older and in opioid agonist treatment, but lower with stimulant use and previous HCV testing, demonstrating feasibility of peer-supported mail-order screening.

    Peer-delivered mail-order self-collection and linkage to treatment for hepatitis C virus infection among users of a harm reduction service in DenmarkDemant et al., The International journal on drug policy (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • serology
  25. 2025

    In 41 Black adults with heart failure, elevated xanthine oxidase activity from capillary blood collected with Mitra microsampling associated significantly with dyspnoea severity. This demonstrates that microsampling can capture clinically relevant inflammatory biomarkers linked to symptom burden in underserved populations, supporting its use in decentralised cardiovascular monitoring.

    Inflammation markers associated with symptoms and neighborhood deprivation in black adults with heart failureButts et al., Heart & lung : the journal of critical care (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • biomarkers
  26. 2025

    An LC-MS/MS assay using volumetric absorptive microsampling achieved 72.5% to 98.9% accuracy and under 8% precision for measuring circulating endocannabinoids and related lipid mediators. However, drying time significantly altered 2-AG and 2-OG concentrations, and marked differences were observed between whole blood and plasma measurements.

    Spotlight on Endocannabinoids in Healthy Individuals Using Volumetric Absorptive Microsampling Combined with LC-MS/MS AnalysisHaroune et al., ACS omega

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • haematocrit
    • biomarkers
  27. 2025

    Among 154 volunteers, 85% found HemaSpot HF self-sampling acceptable, but correlation with venous blood for anti-tetanus toxin IgG was moderate (r = 0.73) and sensitivity varied from 70% to 100% depending on the cut-off value, with concentration differences widening at higher IgG levels. The device requires further improvement before it can reliably replace venous puncture for decentralised serological testing.

    Feasibility of blood self-sampling with HemaSpot HF for Anti-Clostridium tetani Toxin IgG detectionKettlitz et al., Scientific reports

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
    • serology
  28. 2025

    Targeted proteomic evaluation of a novel finger-prick dried plasma device demonstrated strong quantitative correlation with conventional plasma (R = 0.99) and precision under 10% CV for 80% of quantified peptides across healthy donors. Quantified targets also remained stable during room temperature storage for up to 232 days, supporting its use for decentralised biomarker monitoring.

    Quantitative Assessment of a Novel Device Designed for Patient-centric Sampling of Dried Plasma Using Targeted ProteomicsHober et al., Analytical chemistry

    • blood
    • dried
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • dct
    • biomarkers
  29. 2025

    The study found that dried blood spot sampling showed good agreement with plasma concentrations for vancomycin and creatinine, with most differences within 20%, and patients preferred the finger prick method over venepuncture, supporting its use for decentralised therapeutic drug monitoring.

    Clinical validation of an innovative dried whole-blood spot method to quantify simultaneously vancomycin and creatinine in adult patientsHassanzai et al., The Journal of antimicrobial chemotherapy

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • tdm
    • antimicrobials
  30. 2025

    Capillary blood collection using volumetric absorptive microsampling demonstrated equivalent quantification of principal colonic polyphenol metabolites compared with matched venous plasma across a six-hour period following barley biscuit consumption. The technique successfully captured the pharmacokinetic profiles over 48 hours, confirming VAMS as a reliable alternative to venepuncture for dietary biomarker monitoring.

    Finger-prick blood sampling using volumetric absorptive microsampling (VAMS) method for monitoring the main (poly)phenolic metabolites in human blood after barley biscuit intakeCortijo-Alfonso et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • metabolome
    • biomarkers
  31. 2025

    A fully validated LC-MS method quantifies four direct oral anticoagulants and phenprocoumon from 10 µL capillary blood collected with Neoteryx Mitra VAMS devices. Samples remained stable for seven days at room temperature, showed no significant haematocrit effect, and offers a reliable approach for ambulatory therapeutic drug monitoring.

    Development and validation of a quantification method for direct oral anticoagulants from capillary blood using volumetric absorptive microsampling and online SPE-LC-MSOpitz et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • haematocrit
  32. 2025

    VAMS finger-prick sampling showed moderate agreement with conventional venous sampling for clofazimine, with a systematic 13% lower concentration that can be corrected, and was more cost-effective by about 4.45 USD per sample, supporting its use for routine therapeutic drug monitoring in MDR-TB.

    Analytical and clinical validation of a volumetric absorptive microsampling (VAMS) - Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the analysis of Clofazimine in whole bloodNugraha et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • economics
  33. 2025

    The study validated Mitra VAMS devices for detecting nerve agent, sulfur mustard and opioid metabolites in dried human blood, achieving sensitivities between 0.05 and 1 ng/mL across analytes with acceptable precision, accuracy and recovery, supporting their use as a simpler alternative to refrigerated sample transport for forensic exposure verification.

    Evaluation of dried blood spot sampling for verification of exposure to chemical threat agentsWalker et al., Forensic toxicology

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • toxicology
  34. 2025

    Self-sampling of dried blood spots for HIV viral load monitoring proved acceptable among sexual minority men who use stimulants, with 92% returning Tasso-M20 kits and 88% returning HemaSpot HD kits. Participants' device preferences centred on convenience and pain, and they highlighted that clearer instructions, contingency planning, and addressing intersectional stigma are essential for engagement, indicating that patient choice in sampling methods could improve uptake of decentralised diagnostics.

    'I was like, this is gonna hurt': Implementing self-sampling of dried blood spots to measure HIV viral loadChavez et al., PloS one

    • blood
    • dried
    • dbs
    • self-collection
    • acceptability
    • serology
  35. 2025

    A dried blood spot LC-MS/MS method for voclosporin was analytically validated using volumetric sampling devices, demonstrating strong agreement with whole blood analysis across a 10-600 µg/L range. The method meets ICH M10 guidelines and allows remote therapeutic drug monitoring in kidney transplant recipients.

    Dried blood spot LC-MS/MS quantification of voclosporin in renal transplant recipients using volumetric dried blood spot samplingMetscher et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • dbs
    • volumetric
    • validation
    • tdm
    • immunosuppressants
  36. 2025

    In a national surveillance pilot in Georgia, 39.8% of children aged 5-7 years had blood lead levels at or above 3.5 micrograms per decilitre, with predictors including male sex, unpainted housing, urban living in Imereti, and household lead bullet production and spice use in Adjara. The study shows that VAMS is a feasible, less invasive method for accurate lead testing in resource limited settings.

    Blood Lead Levels in Children 5 to 7 Years of Age from the Republic of Georgia: A Feasibility Study on Lead Surveillance Using Volumetric Absorptive MicrosamplingRylander et al., Environmental health perspectives

    • blood
    • dried
    • vams
    • pediatric
  37. 2025

    An optimized 4D-lipidomics UHPLC-HRMS protocol using stable isotope internal standards enabled semi-quantitative profiling of 432 unique lipid features from 10 ̢L dried blood spot samples with high analytical reproducibility. The workflow demonstrates the viability of capillary blood microsampling for large-scale, remote population lipidomics and metabolic profiling.

    Dried blood spot microsampling: A semi-quantitative 4D-lipidomics approach using ultrahigh-performance liquid chromatography - high-resolution mass spectrometry (UHPLC - HRMS)Roberts et al., Talanta (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • metabolome
    • biomarkers
  38. 2025

    Dried blood spot sampling matched venous serum performance for islet autoantibody detection and was considered minimally invasive and convenient by parents and stakeholders, supporting its use for decentralised screening in home or community settings.

    Establishing the performance and acceptability of dried blood spot sampling to screen for islet-specific autoantibodiesFaustini et al., Diabetic medicine : a journal of the British Diabetic Association

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • pediatric
  39. 2025

    The method quantified elexacaftor, tezacaftor and ivacaftor across plasma, dried plasma spots and VAMS with good linearity, accuracy and no matrix effect. Plasma and dried plasma spot results were interchangeable, while VAMS gave lower concentrations due to high protein binding and were corrected using the haematocrit to estimate equivalent plasma levels.

    A Novel LC-MS/MS Method for the Measurement of Elexacaftor, Tezacaftor and Ivacaftor in Plasma, Dried Plasma Spot (DPS) and Whole Blood in Volumetric Absorptive Microsampling (VAMS) DevicesPigliasco et al., Pharmaceutics

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • haematocrit
  40. 2025

    Among people who inject drugs, point-of-care HCV testing was preferred over dried blood spot collection and venepuncture because rapid results reduced anxiety. The study shows that for decentralised screening, non-judgemental care and assisted collection are critical acceptability factors, even when self-collection is available.

    Acceptability of hepatitis C testing using point-of-care testing and dried blood spot collection among people at risk of hepatitis C infectionStevens et al., The International journal on drug policy (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • acceptability
    • serology
  41. 2025

    The study compared five microsampling devices, including Mitra tips and Tasso-M20, for detecting 27 steroid esters in dried blood by LC-MS/MS, and found that methanol extraction with Girard's reagent P or T provided the best screening sensitivity with detection limits of 0.05 to 1.0 ng/mL, while methoxyamine derivatization was recommended for confirming boldenone and certain testosterone esters. The Tasso-M20 device produced chromatographic interference with methanol extraction that was only partially resolved by using mixed solvents, at the cost of lower recoveries.

    Comparability of different analytical workflows for steroid esters detection in doping control fieldMazzarino et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • doping
  42. 2025

    The Ovul portable device, which analyses dried saliva crystallisation patterns to detect the fertile window, achieved 97.4% sensitivity and 97.6% accuracy in women with idiopathic infertility, outperforming urine test strips while both methods maintained 100% specificity against folliculometry. This supports its use as a decentralised, patient‑centric tool for home fertility monitoring that could reduce costs and improve convenience.

    Effectiveness of using ferning of the dried saliva crystallization to determine the fertile window in women with idiopathic infertilityKolomiichenko et al., Wiadomosci lekarskie (paywalled)

    • saliva
    • dried
    • self-collection
    • fertility
    • hormones
  43. 2025

    In an adolescent with cerebral palsy undergoing a home-based, remotely supervised sprint-intensity interval training intervention, dried blood spot testing demonstrated a 37.8% reduction in triglycerides and a 15.4% improvement in total cholesterol to HDL ratio. This illustrates how remote microsampling can support decentralized metabolic monitoring in pediatric disability rehabilitation.

    Sprint-Intensity Arm Interval Training May Improve Cardiorespiratory Fitness and Cardiometabolic Health Among Children With Mobility Disabilities: Case ReportDean et al., JMIR formative research

    • blood
    • dried
    • dbs
    • self-collection
    • pediatric
    • biomarkers
  44. 2025

    The review identifies neurofilament light chain, brain-derived tau, glial fibrillary acidic protein and soluble TREM2 as fluid biomarkers that could monitor axonal damage and glial activation in hereditary spastic paraplegia. It proposes that dried blood spot collection enables minimally invasive longitudinal monitoring of these biomarkers, supporting patient-centred care models for this genetically heterogeneous neurodegenerative disease.

    Fluid Biomarkers in Hereditary Spastic Paraplegia: A Narrative Review and Integrative Framework for Complex Neurodegenerative MechanismsCipriano et al., Genes

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • biomarkers
  45. 2025

    Volumetric dried blood spot microsampling enables retinol analysis with over 90% extraction efficiency from only 10 µL of blood, though α-tocopherol recovery ranges from 53 to 75% depending on filter paper. The method improves sample stability to 30 days at -80°C and reduces shipping volume more than a thousandfold, making micronutrient monitoring practical for decentralised settings.

    Volumetric dried blood spot microsampling: A sustainable, patient-friendly, and practical approach for retinol and α-tocopherol analysis in a clinical settingSuwanvecho et al., Methods (paywalled)

    • blood
    • dried
    • dbs
    • volumetric
    • validation
    • biomarkers
  46. 2025

    Researchers validated a UHPLC-MS/MS assay for citrinin in capillary blood collected with Neoteryx Mitra VAMS devices, plus feces and urine, achieving quantification limits of 0.05 ng/mL. The study derived human toxicokinetic parameters from 48-hour sample collection after a single oral dose, demonstrating that microsampling enables robust population-level exposure assessment for mycotoxins.

    Derivation of Human Toxicokinetic Parameters and Chemical-Specific Adjustment Factor of Citrinin Through a Human Intervention Trial and Hierarchical Bayesian Population ModelingVisintin et al., Toxins

    • blood
    • urine
    • stool
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • toxicology
  47. 2025

    The study develops and validates a dried blood microsampling method for oxylipin analysis in newborn blood using UPLC-MS/MS, showing that small-volume, minimally invasive capillary blood collection is feasible and suitable for unstable, low-abundant analytes, enabling practical decentralised sampling in vulnerable populations.

    Assessment of dried blood micro-sampling methods for oxylipin analysis in newborn blood using UPLC-MS/MSAlbiach-Delgado et al., Analytica chimica acta (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • pediatric
  48. 2025

    In 55 patients, four approaches to convert dried capillary blood concentrations to plasma equivalents were evaluated. All methods except haematocrit-based conversion yielded acceptable analytical and clinical agreement for paracetamol and metabolites, supporting the reliability of capillary microsampling for decentralised therapeutic drug monitoring.

    Comparative Evaluation of Approaches to Convert Microsampled Capillary Blood Concentrations to Plasma Concentrations: Paracetamol and Metabolites as a Case StudyBoffel et al., The AAPS journal (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • dct
    • haematocrit
  49. 2025

    This feasibility study demonstrated that a surrogate matrix solution enables accurate quantitation of a monoclonal antibody from dried blood samples collected via VAMS or Tasso-M20 devices. The method resolves challenges related to daily calibrator preparation and sample dilution for ligand binding assays used in pharmacokinetic studies.

    The Use of Surrogate Matrix for Calibrators in the Analysis of Dried Blood Samples - A Feasibility StudyLee et al., The AAPS journal (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • biologics
  50. 2025

    Capillary volumetric absorptive microsampling showed significant differences in absolute antibiotic concentrations compared to venous plasma, yet it reliably tracked the pharmacokinetic profiles of amoxicillin, metronidazole, and azithromycin over time. The approach was well accepted by both participants and clinicians, indicating its feasibility for less invasive therapeutic drug monitoring in periodontal clinical trials.

    A comparison between venous blood sampling and capillary volumetric absorptive microsampling for antibiotics levels monitoring in individuals with and without periodontal diseaseLazaridi et al., Clinical oral investigations

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • venous-agreement
    • acceptability
    • tdm
    • antimicrobials
  51. 2025

    Whole-genome sequencing of dried blood spots from 1,000 newborns identified 16 infants with high-chance results, most missed by standard screening. The 13-day turnaround and high parental acceptability show a feasible, scalable model for decentralised genomic screening.

    Feasibility, acceptability and clinical outcomes of the BabyScreen+ genomic newborn screening studyLunke et al., Nature medicine

    • blood
    • dried
    • dbs
    • acceptability
    • pediatric
    • genotyping
  52. 2024

    At-home capillary microsampling carried pharmacokinetic sampling across the Paxlovid phase II/III programme, with fewer than 3% of more than 800 samples unusable, and the resulting data supported the Emergency Use Authorization and subsequent FDA approval: remotely collected samples accepted in a registrational filing.

    Patient Centric Microsampling to Support Paxlovid Clinical Development: Bridging and ImplementationWan et al., Clinical Pharmacology & Therapeutics (paywalled)

    • dct
    • volumetric
    • venous-agreement
    • blood
    • self-collection
    • dried
    • capillary
    • validation
  53. 2024

    Head-to-head clinical validation of two VAMS devices for tacrolimus and mycophenolic acid, with roughly 86–88% of samples within ±20% of venous.

    Clinical validation of two volumetric absorptive microsampling devices to support home-based therapeutic drug monitoring of immunosuppressionLeino et al., British Journal of Clinical Pharmacology (paywalled)

    • vams
    • venous-agreement
    • acceptability
    • neoteryx-mitra
    • blood
    • tdm
    • self-collection
    • dried
    • immunosuppressants
    • validation
  54. 2024

    DBS achieved 100% sensitivity, 99% specificity and ~97% concordance versus paired serum: the strength of the classic card for ratio/threshold serology.

    Using Dried Blood Spots to Quantitatively Detect Anti-SARS-CoV-2 IgG Antibodies by ELISA: A Validation StudyYlade et al., American J. Tropical Medicine and Hygiene

    • blood
    • dbs
    • dried
    • serology
    • validation
  55. 2024

    Confirms urine is the second-most-applied VAMS matrix in forensics, collecting a consistent volume regardless of viscosity and enabling room-temperature storage and shipping.

    Volumetric Absorptive Microsampling in ToxicologyReview, Toxics

    • vams
    • volumetric
    • blood
    • dried
    • toxicology
    • urine
    • validation
    • saliva
  56. 2024

    A study of 301 adults with epilepsy providing 464 measurements found that patient-centric capillary VAMS microsampling showed good agreement with plasma for seven of 13 antiseizure medicines, such as carbamazepine and levetiracetam. However, systematic differences remained for valproate, primidone, topiramate, and zonisamide, meaning decentralised monitoring is feasible for most but some drugs need further evaluation.

    Fingerprick volumetric absorptive microsampling for therapeutic drug monitoring of antiseizure medications: Reliability and real-life feasibility in epilepsy patientsCancellerini et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • vams
    • venous-agreement
    • blood
    • tdm
    • self-collection
    • dried
    • capillary
  57. 2024

    A review of 18 studies found that microsampling techniques, including dried blood spot sampling and volumetric absorptive microsampling, are validated for antipsychotic monitoring. Although most studies have shortcomings limiting generalisability, microsampling is recommended for clozapine and is a promising, virtually painless option to support decentralised, patient-centric care.

    Microsampling Techniques Suitable for Therapeutic Drug Monitoring of AntipsychoticsGeers et al., Journal of clinical psychopharmacology (paywalled)

    • vams
    • blood
    • dbs
    • tdm
    • dried
    • validation
  58. 2024

    The study validated a VAMS-based LC-MS/MS method for measuring sirolimus levels, showing it was clinically equivalent to the standard whole blood method and suitable for therapeutic drug monitoring in paediatric transplant patients, supporting the use of decentralised microsampling for this purpose.

    Personalization of pharmacotherapy with sirolimus based on volumetric absorptive microsampling (VAMS) in pediatric renal transplant recipients-from LC-MS/MS method validation to clinical applicationKocur et al., Pharmacological reports : PR

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • tdm
    • haematocrit
    • dried
    • capillary
    • pediatric
    • immunosuppressants
    • validation
  59. 2024

    A study of 152 women found that HbA1c and reproductive hormone levels from menstrual blood collected via a modified pad highly correlated with venous blood, supporting its use as a decentralised surrogate, though interassay variability was noted.

    Concordance of hemoglobin A1c and reproductive hormone levels in menstrual and venous bloodNaseri et al., F&S reports

    • blood
    • dried
    • dbs
    • venous-agreement
    • fertility
    • hormones
  60. 2024

    Patterned DBS cards meter reproducible volumes of dried blood across a range of haematocrits, allowing accurate white blood cell counts by qPCR that match HemoCue measurements. This enables reliable at-home sampling for populations without easy access to clinical facilities.

    Hematocrit-Independent Sampling Enables White Blood Cell Counts from Patterned Dried Blood Spot CardsTierney et al., Analytical chemistry (paywalled)

    • blood
    • dbs
    • self-collection
    • haematocrit
    • dried
    • validation
  61. 2024

    Primary caregivers of children with metabolic disorders found at-home dried blood spot collection acceptable after training, which could enable more timely and cost-effective monitoring. This supports the feasibility of decentralised, patient-centric sampling for long-term condition management.

    Acceptability of dried blood spot collection by primary caregivers of Filipino patients with maple syrup urine disease (MSUD) and phenylketonuria (PKU)Merencilla et al., Journal of community genetics (paywalled)

    • acceptability
    • blood
    • dbs
    • self-collection
    • dried
    • pediatric
  62. 2024

    Microsampling enables less invasive, patient-centric self-collection of capillary blood for remote monitoring of metabolites and lipids, overcoming conventional venipuncture constraints. Recent device innovations address dried blood spot limitations, particularly haematocrit and volume variations, expanding decentralised applications in population health, drug discovery and multi-omics research.

    Revolutionizing Blood Collection: Innovations, Applications, and the Potential of Microsampling Technologies for Monitoring Metabolites and LipidsBossi et al., Metabolites

    • multimodal
    • blood
    • dbs
    • metabolome
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
    • biomarkers
    • multi-omics
  63. 2024

    The paper found that two laboratory assays for the anticoagulants apixaban and rivaroxaban gave markedly different plasma concentrations, and that dried blood volumetric absorptive microsamples taken by patients at home did not agree with plasma results. For decentralised diagnostics this means clinical laboratories must validate their chosen method and always measure haematocrit when using microsamples to ensure accurate anticoagulant monitoring.

    Assays for Monitoring Apixaban and Rivaroxaban in Emergency Settings, State-of-the-Art Routine Analysis, and Volumetric Absorptive Microsamples Deliver Discordant ResultsFehér et al., Diagnostics

    • blood
    • dried
    • vams
    • validation
    • tdm
    • haematocrit
  64. 2024

    The study validated a method for determining 15 trace elements in whole blood collected via VAMS, showing high precision and accuracy with agreement to a liquid sampling method. This supports the use of VAMS for decentralised trace element analysis in clinical and research settings.

    A miniaturized sample preparation method for routine elemental determination in whole blood using volumetric absorptive micro-sampling by ICP-QQQSchmidt et al., Analytical and bioanalytical chemistry (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
  65. 2024

    The study developed and validated a LC-MS/MS method for quantifying Lurasidone using volumetric absorptive microsampling, comparing dried blood and plasma matrices; the method appears precise, accurate and robust, enabling reliable decentralised therapeutic drug monitoring with small-volume dried blood samples.

    Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samplesRajadhyaksha & Londhe, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)

    • blood
    • dried
    • vams
    • validation
    • tdm
  66. 2024

    A feasibility study at a Kathmandu maternity hospital showed newborn metabolic screening using dried blood spots achieved 98.8% parental consent, driven primarily by cost-free participation. Despite pandemic-related transport delays to a central Indian laboratory, results were delivered within two weeks, detecting metabolic abnormalities in 13 of 825 infants, with 90% of healthcare providers endorsing routine implementation.

    Feasibility of clinical newborn metabolic screening in a high-volume maternity center in NepalKhan et al., BMC global and public health

    • blood
    • dried
    • dbs
    • acceptability
    • pediatric
  67. 2024

    This systematic review of 67 studies involving 34,739 kidney disease patients found dried blood microsampling was mainly used for immunosuppressant therapeutic drug monitoring and kidney function assessment. The approach offered cost savings, was preferred by patients for home self-collection, and provides a patient-centric opportunity to upscale longitudinal sampling and reduce participation bias in decentralised kidney disease research.

    A Systematic Literature Review on the Use of Dried Biofluid Microsampling in Patients With Kidney DiseaseLamond et al., Journal of clinical laboratory analysis

    • blood
    • dried
    • capillary
    • self-collection
    • validation
    • acceptability
    • tdm
    • immunosuppressants
    • economics
  68. 2024

    Postpartum women with HIV who had low ART drug concentrations reported more challenges with HIV status disclosure, social support, health system interactions and health beliefs compared with those who had continuously high concentrations; integrating objective adherence biomarkers with patient narratives could enable real time interventions to improve ART adherence and maternal infant outcomes.

    Antiretroviral therapy adherence among peripartum women with HIV in Kenya: an explanatory mixed methods study using dry blood spot measures and narrative interviewsHampanda et al., AIDS care (paywalled)

    • blood
    • dried
    • dbs
    • acceptability
    • tdm
  69. 2024

    A four-item questionnaire for menstrual phase identification, validated against progesterone in dried blood spots, achieved 92.1 per cent accuracy with less restrictive scoring, substantially better than self-reported onset of menses alone (60.2 per cent). This tool could enable accurate phase determination in decentralised research and low-resource settings without intensive clinical assessment.

    Menstrual Phase Identification Questionnaire (MPIQ): Development and validation of a cross-sectional survey to identify follicular and luteal phasesAllen et al., Experimental and clinical psychopharmacology (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • fertility
    • hormones
  70. 2024

    The study found low SARS-CoV-2 seropositivity in unvaccinated children and young adults in British Columbia, with higher rates in South Asian participants and young infants. Many infections were undetected, highlighting the value of patient-centric microsampling for more accurate, decentralised surveillance.

    Factors associated with SARS-CoV-2 infection in unvaccinated children and young adultsSilverberg et al., BMC infectious diseases

    • blood
    • dried
    • dbs
    • acceptability
    • pediatric
    • serology
  71. 2024

    The review found dried blood spot sampling correlates strongly with plasma for HIV-1 viral load and offers simplified collection, transport and storage without cold-chain. This could expand access to monitoring in resource-limited settings and improve clinical outcomes through earlier detection of treatment failure.

    Revolutionizing HIV-1 Viral Load Monitoring in India: The Potential of Dried Blood Spot Analysis for Expanding Access and Improving CareChandane Tak et al., Healthcare

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • serology
  72. 2024

    A statewide remote seroprevalence study using at-home dried blood spot kits achieved a 71.6% sample return rate from registered households, with success dependent on integrated data systems, responsive participant support, and strong health department partnerships. This demonstrates feasibility of large-scale decentralised microsampling for public health surveillance.

    CalScope: methodology and lessons learned for conducting a remote statewide SARS-CoV-2 seroprevalence study in California using an at-home dried blood spot collection kit and online surveyLim et al., BMC medical research methodology

    • blood
    • dried
    • dbs
    • self-collection
    • dct
    • serology
  73. 2024

    Microsampling with Mitra® devices correlated strongly with venous plasma for capecitabine therapeutic drug monitoring (r=0.97), but yielded consistently lower concentrations. Patients preferred this method and reported minimal pain, suggesting it is suitable for patient-centric oncology drug monitoring in decentralised settings.

    Comparison of capecitabine concentrations determined by microsampling versus plasma concentrations for therapeutic drug monitoring: a pilot studyShafiei et al., The Journal of pharmacy and pharmacology (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • acceptability
    • tdm
    • oncology
  74. 2024

    The authors validated a VAMS method for ivermectin therapeutic drug monitoring in whole blood, achieving a lower limit of quantification of 1 ng/mL and a linear range of 1–150 ng/mL. By eliminating haematocrit effects that limit dried blood spots, the method supports accurate decentralised sampling for antiparasitic therapy.

    Development and validation of ivermectin quantification method in volumetric absorptive microsampling using liquid chromatography-tandem mass spectrometryHarahap et al., Heliyon

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • antimicrobials
  75. 2024

    An LC-MS/MS method for warfarin in VAMS samples was validated to FDA 2022 standards, showing linearity from 5–500 ng/mL. Analysis of 25 patients on warfarin therapy yielded concentrations of 6.05–431.39 ng/mL, confirming that self-collected VAMS can reliably support anticoagulation monitoring in decentralised settings.

    Determination of warfarin in volumetric absorptive microsampling by liquid chromatography-tandem mass spectrometryHarahap et al., Heliyon

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm
  76. 2024

    The LC-MS/MS method using VAMS quantified doxorubicin and its metabolite doxorubicinol with linear ranges 8-200 and 3-100 ng/mL and LLOQs of 8 and 3 ng/mL; patient levels ranged 9.47-87.84 ng/mL for doxorubicin and 4.24-54.02 ng/mL for doxorubicinol, enabling TDM with cumulative doses 47.93-346.09 mg/m2 and an estimated cardiomyopathy risk under 4%.

    Doxorubicin, doxorubicinol, cardiotoxicity, breast cancer, volumetric absorptive microsampling, LC-MS/MSChairunnisa et al., Pakistan journal of biological sciences : PJBS (paywalled)

    • blood
    • dried
    • vams
    • tdm
    • oncology
  77. 2024

    The study developed and validated an ICP-MS/MS method for trace elements in whole blood collected on VAMS and found that most targeted elements gave accurate and reproducible results compared with a reference method, indicating that VAMS could become an alternative to venipuncture for blood sampling in trace elements analysis.

    Validation of Mitra<sup>®</sup> VAMS<sup>®</sup> as a blood collection technique for trace elements analysis using ICP-MS/MSBreton et al., Bioanalysis (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
  78. 2024

    The authors validated a UPLC-PDA assay for ceftazidime in 10 microlitre dried blood spots collected with the Capitainer device from neonatal patients, achieving accuracy of 90.1 to 104.8 per cent and precision within 11.7 per cent coefficient of variation across a quantification range of 0.5 to 200 micrograms per millilitre, and confirmed the method worked on clinical neonatal samples. This supports microsampling-based therapeutic drug monitoring of an antimicrobial in a vulnerable population where conventional venous blood draws are difficult.

    Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spotsLv et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • pediatric
    • tdm
    • antimicrobials
  79. 2024

    An analytical method using Capitainer B devices collecting 10 microlitres of capillary blood was successfully validated for the quantitative determination of 25 PFAS using UHPLC-MS/MS. The method demonstrated high recovery above 80% and met precision and accuracy criteria across the validated range of 2 to 100 ng/mL.

    Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spotsGalletto et al., Analytical and bioanalytical chemistry

    • blood
    • dried
    • capillary
    • dbs
    • qdbs
    • validation
    • toxicology
  80. 2024

    Plasma separation cards showed high specificity (99.3%) but moderate sensitivity (87.5%) against EDTA-plasma for HIV-1 viral load monitoring at a 1,000 copies/ml threshold in a South African cohort. Despite favourable usability among healthcare workers, laboratory-reported technical difficulties must be addressed to enable reliable decentralised scale-up in resource-constrained settings.

    Assessment of the performance of the plasma separation card for HIV-1 viral load monitoring in South AfricaChimoyi et al., Journal of clinical microbiology

    • blood
    • dried
    • capillary
    • validation
    • venous-agreement
    • acceptability
    • pediatric
    • serology
  81. 2024

    A dried urine spot method for measuring 14 amino acids was validated using filter paper and mass spectrometry, offering a stable alternative to liquid urine that supports patient self-collection and remote analysis.

    Dried urine spot (DUS) applied for sampling prior to the accurate HILIC-MS/MS determination of 14 amino acidsMeikopoulos et al., Talanta (paywalled)

    • urine
    • dried
    • validation
    • dct
  82. 2024

    A community survey of 1699 Tanzanian children using dried blood spots found 17.4% had residual antibiotics, with half of those exposed having no reported use, showing microsampling can reveal hidden antibiotic exposure for stewardship programmes.

    Prevalence and predictors of residual antibiotics in children's blood in community settings in TanzaniaLotto et al., Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases (paywalled)

    • blood
    • dried
    • dbs
    • pediatric
    • antimicrobials
  83. 2024

    When patiromer is taken three hours after tacrolimus, it does not alter tacrolimus exposure in kidney transplant recipients. The study also shows that self-collected capillary blood samples using volumetric absorptive microsampling (VAMS) can reliably measure tacrolimus concentrations, which simplifies pharmacokinetic studies and enables decentralised therapeutic drug monitoring.

    Patiromer Does Not Alter Tacrolimus Pharmacokinetics in Kidney Transplant Recipients When Administered Three Hours Post-TacrolimusDrevland et al., Transplantation direct

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • self-collection
    • tdm
    • immunosuppressants
    • dct
  84. 2024

    Folate vitamer stability in dried blood microsamples was strongly dependent on temperature and time, with levels remaining within 85 to 115 per cent of baseline at -20°C and 4°C for up to two weeks in both VAMS and DBS, but only lasting three days at room temperature in VAMS and failing at 37°C. The authors conclude that decentralised sampling for folate status monitoring is feasible if transport temperature and duration are controlled, though pretreatment with stabilising agents and desiccant use offered only partial improvement at ambient temperature.

    Is the stability of folates in dried blood microsamples sufficient to perform home-sampling studies?Heughebaert & Stove, The Analyst (paywalled)

    • blood
    • dried
    • vams
    • dbs
    • neoteryx-mitra
    • self-collection
    • validation
    • biomarkers
  85. 2024

    The study developed and validated LC-MS/MS methods for ganciclovir in serum, dried serum spots, and VAMS-Mitra devices. In 80 pediatric renal transplant recipients, VAMS showed interchangeability with serum samples while extending stability to at least 49 days at room temperature, making decentralised therapeutic drug monitoring more feasible for transplant patients.

    Assessment of Dried Serum Spots (DSS) and Volumetric-Absorptive Microsampling (VAMS) Techniques in Therapeutic Drug Monitoring of (Val)Ganciclovir-Comparative Study in Analytical and Clinical PracticeKocur et al., International journal of molecular sciences

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • pediatric
    • tdm
    • antimicrobials
  86. 2024

    Capillary blood collection using liquid and dried microsampling devices yielded pharmacokinetic profiles comparable to venous sampling for two monoclonal antibodies and a small molecule, whereas haematocrit correction was necessary for dried formats and bridging was ineffective for hydroxychloroquine. The findings demonstrate the bioanalytical feasibility and patient acceptability of remote microsampling tools for pharmacokinetic evaluations in decentralised clinical trials.

    Evaluation of Patient-Centric Sample Collection Technologies for Pharmacokinetic Assessment of Large and Small MoleculesMandlekar et al., Clinical pharmacology and therapeutics (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • neoteryx-mitra
    • validation
    • venous-agreement
    • acceptability
    • tdm
    • biologics
    • dct
    • haematocrit
  87. 2024

    Low volume sampling devices showed good concordance with venous serum for measuring the pharmacodynamic biomarker sMAdCAM-1, but dried blood samples required substantial dilution to overcome buffer interference, which was mitigated by using a highly sensitive Simoa assay. The study demonstrates that while these devices have potential for decentralised clinical trials, careful validation is needed to address site-specific biases and assay sensitivity limitations.

    Evaluation of low volume sampling devices for a pharmacodynamic biomarker analysis: Challenges and solutionsYang et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • liquid
    • dried
    • neoteryx-mitra
    • validation
    • venous-agreement
    • dct
    • biomarkers
  88. 2024

    Self-collected dried blood spots analysed on the Roche Elecsys platform gave quantitative anti-spike antibody results that agreed closely with paired venous samples, with sensitivity 96.63% and specificity 97.81% and a conversion formula across 0.018 to 250 U/mL, enabling accurate tracking of titre changes in longitudinal cohorts after vaccination.

    A Dried Blood Spot protocol for high-throughput quantitative analysis of SARS-CoV-2 RBD serology based on the Roche Elecsys systemCastelletti et al., Microbiology spectrum

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • serology
  89. 2024

    Steroid hormones in dried blood spots remained within 15% of baseline for up to 14 days at 37C, and for up to 6 months at -20C, 4C and room temperature, with specific exceptions for androstenedione, 17-OHP, cortisone and cortisol. These findings support the use of DBS for decentralised hormone monitoring by defining storage limits that preserve analyte integrity during transit and storage.

    Stability of steroid hormones in dried blood spots (DBS)Olthof et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • hormones
  90. 2024

    A validated LC-MS method quantified multiple antibiotics from a single volumetric absorptive microsample, with stability up to 90 days for most analytes and minimal haematocrit effect except vancomycin, enabling pharmacokinetic and pharmacodynamic studies in decentralised settings.

    Bioanalysis of six antibiotics from volumetric microsamples: a new tool for precision dosing in critically ill childrenTakyi-Williams et al., Bioanalysis (paywalled)

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • pediatric
    • tdm
    • antimicrobials
    • haematocrit
  91. 2024

    The study validated an LC-HRMS method for measuring breast cancer drugs in plasma, urine, VAMS and oral fluid, showing that all matrices except oral fluid for certain drugs can support decentralised therapeutic drug monitoring. VAMS and oral fluid faced practical challenges in collection due to patient conditions, but the method enables patient-centric monitoring with dried blood and other self-collected samples.

    Towards clinical adherence monitoring of oral endocrine breast cancer therapies by LC-HRMS-method development, validation, comparison of four sample matrices, and proof of conceptJacobs et al., Analytical and bioanalytical chemistry

    • blood
    • saliva
    • urine
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm
    • oncology
  92. 2024

    Portable mid‑infrared spectroscopy combined with chemometrics classified fibromyalgia and other rheumatologic syndromes from dried blood collected by volumetric absorptive microsampling with 84% accuracy, 83% sensitivity and 85% specificity; spectral regions linked to amide bands and amino acids acted as discriminatory features, offering a point‑of‑care screening tool for decentralised diagnostics.

    Portable Mid-Infrared Spectroscopy Combined with Chemometrics to Diagnose Fibromyalgia and Other Rheumatologic Syndromes Using Rapid Volumetric Absorptive MicrosamplingNuguri et al., Molecules

    • blood
    • dried
    • vams
    • neoteryx-mitra
  93. 2024

    The authors validated an LC-HRMS/MS assay for steroids and thyroid hormones in 30 microlitres of capillary blood collected with Neoteryx Mitra VAMS devices, demonstrating storage stability of over 28 days frozen and 14 days at room temperature. Using authentic samples from 50 healthy active adults, the method showed adequate sensitivity to detect the reduced hormone concentrations seen in relative energy deficiency in sport, supporting self-collected VAMS as a practical tool for regular hormone monitoring in athletes.

    Development of an LC-HRMS/MS Method for Quantifying Steroids and Thyroid Hormones in Capillary Blood: A Potential Tool for Assessing Relative Energy Deficiency in Sport (RED-S)Tuma et al., Metabolites

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • hormones
  94. 2024

    This study found that dried blood spot samples stored at room temperature for four years correlated highly with serum measurements for testosterone and androstenedione, indicating that hematocrit adjustment may be unnecessary for serial monitoring in home-based self-sampling.

    Dried blood spot sampling of testosterone microdosing in healthy femalesDesai et al., The Journal of steroid biochemistry and molecular biology (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • fertility
    • hormones
    • haematocrit
  95. 2024

    The study found that DBS testing showed high specificity for HIV, HBV and HCV and perfect sensitivity for HIV and HBV, but lower sensitivity for syphilis and HCV, with creatinine measurements slightly higher than venous samples. Despite challenges in sample adequacy, DBS was acceptable to participants and could support decentralised STI and renal monitoring in men who have sex with men.

    Use of Home-Based Self-Collected Dried Blood Spots to Test for Syphilis, Human Immunodeficiency Virus, Hepatitis C and B Virus Infections and Measuring Creatinine ConcentrationNieuwenburg et al., Sexually transmitted diseases

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
    • serology
    • sti
  96. 2024

    An on-line SPE-LC-MS method using 10 microlitre capillary blood samples collected on VAMS tips achieved lower limits of quantitation of 0.03 micromolar for methotrexate and 7-OH-MTX and 0.05 micromolar for DAMPA, with acceptable accuracy and precision. A plasma-to-whole-blood correlation factor of 0.46 was observed, supporting low-volume pediatric drug monitoring.

    Development and validation of a bioanalytical method for the quantification of methotrexate from serum and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MSOpitz et al., Journal of chromatography. A (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • pediatric
    • tdm
    • oncology
  97. 2024

    The study validated a VAMS-based method for measuring cenobamate in capillary blood, showing high precision accuracy and stability at room temperature for up to 15 days. Cenobamate levels in VAMS samples agreed with those in venous plasma, supporting its use in decentralised therapeutic drug monitoring for epilepsy patients.

    A VAMS-based LC-MS/MS method for precise cenobamate quantification in epilepsy (patients)Pigliasco et al., Epilepsia open

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • tdm
  98. 2024

    An LC-MS/MS method for seven antiepileptic drugs was validated using dried blood and dried plasma spots, showing acceptable precision and accuracy. Samples remained stable for seven days at ambient temperature and 40°C, with good correlation to wet plasma concentrations, supporting decentralised therapeutic drug monitoring with self-collection and room-temperature transport.

    Simultaneous monitoring of seven antiepileptic drugs by dried blood spot and dried plasma spot sampling: method validation and clinical application of a LC-MS/MS-based techniqueCao et al., Journal of pharmaceutical and biomedical analysis (paywalled)

    • blood
    • dried
    • dbs
    • validation
    • venous-agreement
    • tdm
  99. 2024

    A validated high-throughput LC-MS/MS assay for piperaquine from dried blood spots achieved 54-72% recovery with <9% relative standard deviation and a quantification limit of 3 ng/mL, enabling detection for 4-8 weeks post-dose. The method showed minimal haematocrit interference and is suitable for therapeutic drug monitoring of antimalarial treatment in resource-limited settings and pediatric populations.

    A high-throughput LC-MS/MS assay for piperaquine from dried blood spots: Improving malaria treatment in resource-limited settingsBlessborn et al., Journal of mass spectrometry and advances in the clinical lab

    • blood
    • dried
    • capillary
    • dbs
    • validation
    • tdm
    • antimicrobials
    • haematocrit
  100. 2024

    This pilot study of 15 subjects demonstrated that dried fecal spots on quantitative DBS devices yielded bile acid profiles equivalent to frozen samples after four months of ambient storage and shipping. This validates a decentralised stool microsampling method that could enable patient home testing and expand screening in rural or resource-limited settings.

    Repurposing dried blood spot device technology to examine bile acid profiles in human dried fecal spot samplesEngevik et al., American journal of physiology. Gastrointestinal and liver physiology (paywalled)

    • stool
    • dried
    • qdbs
    • self-collection
    • validation
    • metabolome

Read from the corpus on .