The Library
1530 papers on microsampling and monitoring, each with a finding paraphrased to our standard and labelled in one vocabulary. Every entry links to a legitimate copy; nothing is copied from an abstract.
Papers 101–200 of 301 labelled “capillary”, newest first.
2025
Capillary blood sampling showed near-perfect correlation with venous sampling for total PSA across a wide clinical range with negligible bias, and samples remained stable at ambient temperature for up to eight days, supporting feasibility of home self-testing for prostate cancer.
Total Prostate-Specific Antigen (PSA) Testing in Capillary Samples: Proof-of-Principle and Feasibility Study for Home Self-Testing for Prostate Cancer — Sodi et al., The journal of applied laboratory medicine (paywalled)
- blood
- liquid
- capillary
- validation
- venous-agreement
2025
Capillary blood collected by fingerstick or microblade devices produced metabolite profiles that were virtually identical to venous samples when the same biofluid type was compared. This validation study demonstrates that inexpensive microsampling systems can deliver comparable metabolomics data, supporting their use in decentralised diagnostics.
Quantitative comparison of whole blood, plasma and serum metabolomes across different blood collection methods — Zubkowski et al., Metabolomics : Official journal of the Metabolomic Society (paywalled)
- blood
- capillary
- validation
- venous-agreement
- metabolome
2025
Erythropoietin was unstable in urine stored at room temperature or 37 degrees, with degradation in eight of twelve participants, while serum samples showed greater stability. Recombinant EPO detectability was identical across urine, venous serum and capillary serum collected with the Tasso+ SST device, leading the authors to recommend capillary serum collection for doping control to improve overall detection of erythropoiesis-stimulating agents.
Assessing EPO stability in urine and comparing recombinant EPO detectability in matched urine, venous serum, and capillary serum following a controlled epoetin alfa administration — Miller et al., Drug testing and analysis (paywalled)
- blood
- urine
- capillary
- validation
- venous-agreement
- doping
2025
Endogenous erythropoietin was detectable in 100% of microvolumetric capillary serum samples shipped at ambient temperature, and recombinant erythropoietin remained detectable under varied storage and shipping conditions except extreme heat, indicating that blood microsamples can be shipped without cold chain for ERA testing.
Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing — Miller et al., Drug testing and analysis (paywalled)
- blood
- capillary
- validation
- doping
2025
Capillary whole blood collected with RedDrop and Tasso+ devices showed excellent laboratory agreement with venous blood for complete blood count parameters except platelets, indicating that microcapillary sampling is a valid alternative to venepuncture for anti-doping athlete biological passport testing.
Comparison of Microcapillary Blood Sampling Devices for Use in Anti-Doping — Lewis et al., Drug testing and analysis (paywalled)
- blood
- liquid
- capillary
- validation
- venous-agreement
- doping
2025
In this decentralised n-of-1 crossover trial of dapagliflozin in 20 adults with type 2 diabetes, remote collection of urine and capillary blood samples achieved 99.4% and 98.4% delivery success respectively, demonstrating that remote monitoring can reliably track individual albuminuria responses to therapy.
Albuminuria Responses to Dapagliflozin in Patients With Type 2 Diabetes: A Crossover Trial — Beernink et al., JAMA network open
- blood
- urine
- capillary
- self-collection
- dct
2025
Dried blood spot sampling matched venous serum performance for islet autoantibody detection and was considered minimally invasive and convenient by parents and stakeholders, supporting its use for decentralised screening in home or community settings.
Establishing the performance and acceptability of dried blood spot sampling to screen for islet-specific autoantibodies — Faustini et al., Diabetic medicine : a journal of the British Diabetic Association
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
- pediatric
2025
In 22 adults, capillary blood collection demonstrated strong correlation with venous sampling for 66 per cent of inflammatory proteins and moderate to strong correlation for 80 per cent overall, supporting its validity for proteomic measurement in decentralised trials.
Comparing Venous vs. Capillary Blood Collection Methods for Proteomic Measurement in Peripheral Blood — Ni Lochlainn et al., Proteomics. Clinical applications
- blood
- capillary
- validation
- venous-agreement
- dct
- biomarkers
2025
Over two years, 1,507 participants used in-home capillary blood spot sampling for islet autoantibody screening, with only one reporting collection failure, compared with five failures among 276 venipuncture participants. Blood spot sampling reached younger and regionally based Australians at lower cost and with greater convenience, identifying preclinical type 1 diabetes at expected prevalence and supporting early diagnosis without the barriers of clinic-based venous draws.
Islet Autoantibody Screening Throughout Australia Using In-Home Blood Spot Sampling: 2-Year Outcomes of Type1Screen — Wentworth et al., Diabetes care (paywalled)
- blood
- capillary
- dbs
- self-collection
- venous-agreement
- pediatric
2025
In adults, cleaning the fingertip with an alcohol swab did not significantly change capillary glucose readings compared with handwashing, whether the alcohol was left wet or allowed to dry completely. This supports the continued safe use of alcohol swabs before capillary glucose testing in clinical and home settings.
Effect of Alcohol Swab on Blood Glucose Readings Using a Glucometer: A Quasi-Experimental Study — Al-Aithan et al., Cureus
- blood
- liquid
- capillary
- validation
2025
Researchers validated a UHPLC-MS/MS assay for citrinin in capillary blood collected with Neoteryx Mitra VAMS devices, plus feces and urine, achieving quantification limits of 0.05 ng/mL. The study derived human toxicokinetic parameters from 48-hour sample collection after a single oral dose, demonstrating that microsampling enables robust population-level exposure assessment for mycotoxins.
Derivation of Human Toxicokinetic Parameters and Chemical-Specific Adjustment Factor of Citrinin Through a Human Intervention Trial and Hierarchical Bayesian Population Modeling — Visintin et al., Toxins
- blood
- urine
- stool
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- toxicology
2025
In 55 patients, four approaches to convert dried capillary blood concentrations to plasma equivalents were evaluated. All methods except haematocrit-based conversion yielded acceptable analytical and clinical agreement for paracetamol and metabolites, supporting the reliability of capillary microsampling for decentralised therapeutic drug monitoring.
Comparative Evaluation of Approaches to Convert Microsampled Capillary Blood Concentrations to Plasma Concentrations: Paracetamol and Metabolites as a Case Study — Boffel et al., The AAPS journal (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- dct
- haematocrit
2025
Capillary volumetric absorptive microsampling showed significant differences in absolute antibiotic concentrations compared to venous plasma, yet it reliably tracked the pharmacokinetic profiles of amoxicillin, metronidazole, and azithromycin over time. The approach was well accepted by both participants and clinicians, indicating its feasibility for less invasive therapeutic drug monitoring in periodontal clinical trials.
A comparison between venous blood sampling and capillary volumetric absorptive microsampling for antibiotics levels monitoring in individuals with and without periodontal disease — Lazaridi et al., Clinical oral investigations
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- venous-agreement
- acceptability
- tdm
- antimicrobials
2025
Capillary blood collected with a Tasso+ device showed excellent agreement with venous serum for testosterone, the testosterone/androstenedione ratio, and luteinising hormone in 20 adults tracked over six weeks. The biomarkers remained stable when capillary samples were stored at room temperature, suggesting capillary microsampling could enable decentralised, patient-centric collection for the Athlete Biological Passport without cold-chain logistics.
Is blood blood? Comparing quantitation of endogenous steroids and luteinizing hormone in concurrently collected venous serum and Tasso+ SST capillary serum samples — Goodrum et al., Drug testing and analysis (paywalled)
- blood
- capillary
- validation
- venous-agreement
- hormones
- doping
2025
Capillary finger-stick blood showed excellent comparability with venous samples for 30 of 33 routine chemistry analytes against total allowable error criteria, and met CLIA 2024 proficiency testing limits for all but glucose. This validates capillary sampling as a clinically acceptable alternative for most routine tests, benefiting patients with needle phobia and enabling remote sampling.
Comparison of capillary finger stick and venous blood sampling for 34 routine chemistry analytes: potential for in hospital and remote blood sampling — Doeleman et al., Clinical chemistry and laboratory medicine (paywalled)
- blood
- liquid
- capillary
- validation
- venous-agreement
2025
The authors observe that self-sampling devices for capillary blood are gaining traction as a patient-preferred alternative to venous collection, with one centre reporting a 15 percent reduction in laboratory test volumes when local collection was offered. They argue that successful integration into total laboratory automation requires addressing cost, transport regulations and sample volume adequacy while ensuring robust device design and seamless workflow compatibility.
Blood self-sampling devices: innovation, interpretation and implementation in total lab automation — Poland & Cobbaert, Clinical chemistry and laboratory medicine (paywalled)
- blood
- liquid
- capillary
- self-collection
- acceptability
2024
At-home capillary microsampling carried pharmacokinetic sampling across the Paxlovid phase II/III programme, with fewer than 3% of more than 800 samples unusable, and the resulting data supported the Emergency Use Authorization and subsequent FDA approval: remotely collected samples accepted in a registrational filing.
Patient Centric Microsampling to Support Paxlovid Clinical Development: Bridging and Implementation — Wan et al., Clinical Pharmacology & Therapeutics (paywalled)
- dct
- volumetric
- venous-agreement
- blood
- self-collection
- dried
- capillary
- validation
2024
In 91 children and adults, capillary C-peptide taken with the TAP device matched venous sampling with 100% sensitivity and specificity for a clinically relevant level, 200 pmol/L or above, with r = 0.996. 63% preferred it to a needle against 7% who preferred the needle, and same-day bruising was 5.5% versus 34.8% after a venous draw.
Transdermal blood sampling for C-peptide is a minimally invasive, reliable alternative to venous sampling in children and adults with type 1 diabetes — Besser et al., Diabetes Care
- blood
- liquid
- yourbio
- capillary
- pediatric
- venous-agreement
- acceptability
- validation
2024
In at-home and trial settings, a wet capillary device reliably collected a median ~450 µL with a 4.4% failure rate; 88% of adults preferred self-collection over venipuncture, with lower pain.
Feasibility, acceptability and safety of a device for self-collecting capillary blood in clinical trials — Dasari et al., PLOS ONE
- acceptability
- blood
- self-collection
- capillary
- pediatric
- liquid
- validation
2024
A study of 301 adults with epilepsy providing 464 measurements found that patient-centric capillary VAMS microsampling showed good agreement with plasma for seven of 13 antiseizure medicines, such as carbamazepine and levetiracetam. However, systematic differences remained for valproate, primidone, topiramate, and zonisamide, meaning decentralised monitoring is feasible for most but some drugs need further evaluation.
Fingerprick volumetric absorptive microsampling for therapeutic drug monitoring of antiseizure medications: Reliability and real-life feasibility in epilepsy patients — Cancellerini et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- vams
- venous-agreement
- blood
- tdm
- self-collection
- dried
- capillary
2024
The study found excellent agreement between hCG levels measured in remotely collected capillary blood and standard venous samples, with a near-perfect correlation. This demonstrates that remote self-collection is a feasible and acceptable alternative for serial pregnancy monitoring, reducing the need for clinic visits.
Proof-of-concept study: Remote capillary blood collection for hCG analysis in early pregnancy — Joyce et al., European journal of obstetrics, gynecology, and reproductive biology (paywalled)
- venous-agreement
- acceptability
- blood
- self-collection
- capillary
- fertility
- hormones
- liquid
2024
Plasma total carbon dioxide concentrations were significantly lower in BD Microtainers compared to standard vacutainers, with reductions driven by low sample volume and transport delays rather than brief air exposure. These findings indicate that microtainers must be filled completely and analysed rapidly to maintain accuracy for this analyte.
Impact of blood volume, air exposure duration, transport duration, and testing delay on plasma total carbon dioxide in simulated open collections using microtainers — Reid et al., Clinical biochemistry (paywalled)
- blood
- liquid
- capillary
- bd-microtainer
- validation
2024
The study validated a VAMS-based LC-MS/MS method for measuring sirolimus levels, showing it was clinically equivalent to the standard whole blood method and suitable for therapeutic drug monitoring in paediatric transplant patients, supporting the use of decentralised microsampling for this purpose.
Personalization of pharmacotherapy with sirolimus based on volumetric absorptive microsampling (VAMS) in pediatric renal transplant recipients-from LC-MS/MS method validation to clinical application — Kocur et al., Pharmacological reports : PR
- vams
- venous-agreement
- neoteryx-mitra
- blood
- tdm
- haematocrit
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2024
This study evaluated the repeatability of a point-of-care G6PD test using capillary blood collected via fingerprick and BD Microtainers, finding that modified sample application methods reduced variability in laboratory and field settings.
Field assessment of the operating procedures of a semi-quantitative G6PD Biosensor to improve repeatability of routine testing — Sadhewa et al., PloS one
- blood
- liquid
- capillary
- bd-microtainer
- validation
2024
Capillary sampling gave TSH and FT4 results that closely matched venous values, with Spearman correlations of 0.99 and 0.97 respectively. This supports using small capillary samples for remote thyroid function testing.
Determination of Capillary Blood TSH and Free Thyroxine Levels Using Digital Immunoassay — Suzuki et al., Journal of the Endocrine Society
- venous-agreement
- blood
- capillary
- hormones
- yourbio
2024
Capillary serum collected with Tasso-SST and Tasso+ devices correlated with venous plasma at r = 0.98 for abrocitinib and its three metabolites, and exposure met bioequivalence criteria; the authors present this as the basis for using Tasso devices in future paediatric studies of abrocitinib.
Patient-centric microsampling for abrocitinib pharmacokinetics: multiple-analytes assay bridging using Tasso device — Tripathy et al., Bioanalysis
- blood
- capillary
- venous-agreement
- pediatric
- tdm
2024
Capillary sampling for carcinoembryonic antigen showed near perfect agreement with venous results and was preferred by most participants, supporting reliable home based collection that could reduce hospital visits.
Feasibility, reliability and satisfaction of (automated) capillary carcinoembryonic antigen measurements for future home-based blood sampling: the prospective CASA-I study — Voigt et al., Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland (paywalled)
- venous-agreement
- acceptability
- blood
- self-collection
- oncology
- colorectal
- capillary
- yourbio
2024
Capillary blood self-collection yielded protein concentrations that matched venipuncture for only a minority of analytes, with 34 of 230 proteins showing acceptable correlation and low variability, while the remainder were more variable; this suggests capillary sampling can support decentralised proteomics for a subset of proteins but may not be universally interchangeable with venipuncture.
Capillary blood self-collection for high-throughput proteomics — El-Sabawi et al., Proteomics
- venous-agreement
- blood
- self-collection
- capillary
- liquid
- biomarkers
2024
Capillary finger prick sampling at home showed close agreement with venous sampling for measuring infliximab, vedolizumab and CRP, with no systematic bias and high patient tolerability and practicality, supporting decentralised monitoring of biologic therapy in IBD.
Clinical Validation of a Capillary Blood Home-Based Self-Sampling Technique for Monitoring of Infliximab, Vedolizumab, and C-Reactive Protein Concentrations in Patients With Inflammatory Bowel Disease — Otten et al., Inflammatory bowel diseases
- blood
- liquid
- capillary
- self-collection
- venous-agreement
- acceptability
- tdm
- biologics
2024
Microsampling enables less invasive, patient-centric self-collection of capillary blood for remote monitoring of metabolites and lipids, overcoming conventional venipuncture constraints. Recent device innovations address dried blood spot limitations, particularly haematocrit and volume variations, expanding decentralised applications in population health, drug discovery and multi-omics research.
Revolutionizing Blood Collection: Innovations, Applications, and the Potential of Microsampling Technologies for Monitoring Metabolites and Lipids — Bossi et al., Metabolites
- multimodal
- blood
- dbs
- metabolome
- self-collection
- haematocrit
- dried
- capillary
- validation
- biomarkers
- multi-omics
2024
This study of 82 children with concussion found that capillary blood collected with a Mitra device within 48 hours of injury could not identify protein markers that predict persistent posttraumatic headache at two weeks. The negative result highlights the need for novel biomarker discovery to enable risk stratification in paediatric concussion using decentralised sampling.
Capillary blood protein markers of posttraumatic headache in children after concussion — Fan et al., Journal of neurosurgery. Pediatrics (paywalled)
- blood
- capillary
- vams
- neoteryx-mitra
- pediatric
- biomarkers
2024
This systematic review of 67 studies involving 34,739 kidney disease patients found dried blood microsampling was mainly used for immunosuppressant therapeutic drug monitoring and kidney function assessment. The approach offered cost savings, was preferred by patients for home self-collection, and provides a patient-centric opportunity to upscale longitudinal sampling and reduce participation bias in decentralised kidney disease research.
A Systematic Literature Review on the Use of Dried Biofluid Microsampling in Patients With Kidney Disease — Lamond et al., Journal of clinical laboratory analysis
- blood
- dried
- capillary
- self-collection
- validation
- acceptability
- tdm
- immunosuppressants
- economics
2024
A short fasting test initiated overnight at home and completed in an outpatient setting diagnosed insulinoma in 11 of 12 patients within 24 hours (91.7% sensitivity). This decentralised approach avoids prolonged inpatient monitoring while maintaining diagnostic accuracy.
Short fasting test as a reliable and effective tool to diagnose insulinoma — Mikovic et al., Endocrine
- blood
- liquid
- capillary
- venous-agreement
- hormones
2024
Microsampling with Mitra® devices correlated strongly with venous plasma for capecitabine therapeutic drug monitoring (r=0.97), but yielded consistently lower concentrations. Patients preferred this method and reported minimal pain, suggesting it is suitable for patient-centric oncology drug monitoring in decentralised settings.
Comparison of capecitabine concentrations determined by microsampling versus plasma concentrations for therapeutic drug monitoring: a pilot study — Shafiei et al., The Journal of pharmacy and pharmacology (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- acceptability
- tdm
- oncology
2024
The study developed and validated an ICP-MS/MS method for trace elements in whole blood collected on VAMS and found that most targeted elements gave accurate and reproducible results compared with a reference method, indicating that VAMS could become an alternative to venipuncture for blood sampling in trace elements analysis.
Validation of Mitra<sup>®</sup> VAMS<sup>®</sup> as a blood collection technique for trace elements analysis using ICP-MS/MS — Breton et al., Bioanalysis (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
2024
The authors validated a UPLC-PDA assay for ceftazidime in 10 microlitre dried blood spots collected with the Capitainer device from neonatal patients, achieving accuracy of 90.1 to 104.8 per cent and precision within 11.7 per cent coefficient of variation across a quantification range of 0.5 to 200 micrograms per millilitre, and confirmed the method worked on clinical neonatal samples. This supports microsampling-based therapeutic drug monitoring of an antimicrobial in a vulnerable population where conventional venous blood draws are difficult.
Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spots — Lv et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- blood
- dried
- capillary
- dbs
- validation
- pediatric
- tdm
- antimicrobials
2024
An analytical method using Capitainer B devices collecting 10 microlitres of capillary blood was successfully validated for the quantitative determination of 25 PFAS using UHPLC-MS/MS. The method demonstrated high recovery above 80% and met precision and accuracy criteria across the validated range of 2 to 100 ng/mL.
Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spots — Galletto et al., Analytical and bioanalytical chemistry
- blood
- dried
- capillary
- dbs
- qdbs
- validation
- toxicology
2024
Plasma separation cards showed high specificity (99.3%) but moderate sensitivity (87.5%) against EDTA-plasma for HIV-1 viral load monitoring at a 1,000 copies/ml threshold in a South African cohort. Despite favourable usability among healthcare workers, laboratory-reported technical difficulties must be addressed to enable reliable decentralised scale-up in resource-constrained settings.
Assessment of the performance of the plasma separation card for HIV-1 viral load monitoring in South Africa — Chimoyi et al., Journal of clinical microbiology
- blood
- dried
- capillary
- validation
- venous-agreement
- acceptability
- pediatric
- serology
2024
When patiromer is taken three hours after tacrolimus, it does not alter tacrolimus exposure in kidney transplant recipients. The study also shows that self-collected capillary blood samples using volumetric absorptive microsampling (VAMS) can reliably measure tacrolimus concentrations, which simplifies pharmacokinetic studies and enables decentralised therapeutic drug monitoring.
Patiromer Does Not Alter Tacrolimus Pharmacokinetics in Kidney Transplant Recipients When Administered Three Hours Post-Tacrolimus — Drevland et al., Transplantation direct
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- self-collection
- tdm
- immunosuppressants
- dct
2024
The Tasso+ device, which uses a vacuum to collect capillary blood from the upper arm, gathered an average of 536 microlitres of whole blood from 47 men who have sex with men using PrEP, with 91% of samples sufficient for HIV testing and 89% for syphilis testing. Acceptability was high, with 87% expressing a positive attitude and 77% willing to use the device again for home self-sampling.
Using an Innovative Method for Self-Collection of Capillary Blood for HIV and Syphilis Testing Among Men Who Have Sex With Men Who Use Pre-exposure Prophylaxis in the Netherlands; Limburg4zero — Goense et al., Sexually transmitted diseases (paywalled)
- blood
- liquid
- capillary
- self-collection
- validation
- acceptability
- serology
- sti
2024
Capillary blood collection using liquid and dried microsampling devices yielded pharmacokinetic profiles comparable to venous sampling for two monoclonal antibodies and a small molecule, whereas haematocrit correction was necessary for dried formats and bridging was ineffective for hydroxychloroquine. The findings demonstrate the bioanalytical feasibility and patient acceptability of remote microsampling tools for pharmacokinetic evaluations in decentralised clinical trials.
Evaluation of Patient-Centric Sample Collection Technologies for Pharmacokinetic Assessment of Large and Small Molecules — Mandlekar et al., Clinical pharmacology and therapeutics (paywalled)
- blood
- liquid
- dried
- capillary
- neoteryx-mitra
- validation
- venous-agreement
- acceptability
- tdm
- biologics
- dct
- haematocrit
2024
This study found that dried blood spot samples stored at room temperature for four years correlated highly with serum measurements for testosterone and androstenedione, indicating that hematocrit adjustment may be unnecessary for serial monitoring in home-based self-sampling.
Dried blood spot sampling of testosterone microdosing in healthy females — Desai et al., The Journal of steroid biochemistry and molecular biology (paywalled)
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- fertility
- hormones
- haematocrit
2024
An on-line SPE-LC-MS method using 10 microlitre capillary blood samples collected on VAMS tips achieved lower limits of quantitation of 0.03 micromolar for methotrexate and 7-OH-MTX and 0.05 micromolar for DAMPA, with acceptable accuracy and precision. A plasma-to-whole-blood correlation factor of 0.46 was observed, supporting low-volume pediatric drug monitoring.
Development and validation of a bioanalytical method for the quantification of methotrexate from serum and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MS — Opitz et al., Journal of chromatography. A (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- pediatric
- tdm
- oncology
2024
A validated high-throughput LC-MS/MS assay for piperaquine from dried blood spots achieved 54-72% recovery with <9% relative standard deviation and a quantification limit of 3 ng/mL, enabling detection for 4-8 weeks post-dose. The method showed minimal haematocrit interference and is suitable for therapeutic drug monitoring of antimalarial treatment in resource-limited settings and pediatric populations.
A high-throughput LC-MS/MS assay for piperaquine from dried blood spots: Improving malaria treatment in resource-limited settings — Blessborn et al., Journal of mass spectrometry and advances in the clinical lab
- blood
- dried
- capillary
- dbs
- validation
- tdm
- antimicrobials
- haematocrit
2024
This review of remote HbA1c testing via capillary blood microsampling finds that both dried and liquid formats can produce results comparable to venous sampling when collection, stability and extraction are properly validated. It matters because self-collected microsamples could enable decentralised diabetes monitoring and telemedicine, but heterogeneity in study designs and methods must be resolved before reliable implementation.
Remote HbA<sub>1c</sub> testing via microsampling: fit for purpose? — Verougstraete et al., Clinical chemistry and laboratory medicine (paywalled)
- blood
- liquid
- dried
- capillary
- self-collection
- validation
- venous-agreement
- acceptability
2024
Dried blood microsamplers (Mitra) and dried blood spots maintained metabolite stability comparable to plasma at minus 80 degrees Celsius, and both dried formats remained stable at minus 20 degrees Celsius while plasma showed reduced stability. At refrigerated temperature, Mitra microsampler profiles were more stable than plasma or dried blood spots, particularly for lipids, suggesting capillary blood microsampling could support sample collection outside clinical settings where ultra-cold storage is unavailable.
Effects of storage temperature and time on metabolite profiles measured in dried blood spots, dried blood microsamplers, and plasma — Petrick et al., The Science of the total environment (paywalled)
- blood
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- validation
- metabolome
2024
Filtered protein precipitation was the most effective extraction method for 75 per- and polyfluoroalkyl substances from dried blood spots collected with a capillary microsampler, recovering 72 analytes within 70–130% with limits of detection from 0.05 to 0.34 ng/mL. The method detected 16 PFAS in self-collected human samples, demonstrating feasibility for large-scale biomonitoring studies using minimally invasive sampling.
Validating blood microsampling for per- and polyfluoroalkyl substances quantification in whole blood — Partington et al., Journal of chromatography. A (paywalled)
- blood
- dried
- capillary
- dbs
- validation
- toxicology
2024
Capillary dried blood spots collected during professional triathlon competitions detected endogenous erythropoietin in all 111 athletes using Tasso-M20 devices, even when matching urine samples were negative. Mitra VAMS devices also sensitively detected recombinant EPO micro-doses and the EPO c.577del variant, confirming that microsampling provides a viable complementary matrix for decentralised doping analysis.
Dried blood spots for erythropoietin analysis: Detection of micro-doses, EPO c.577del variant and comparison with in-competition matching urine samples — Heiland et al., Drug testing and analysis (paywalled)
- blood
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- validation
- doping
2024
In young elite footballers with regular cycles, salivary progesterone correlated strongly with capillary blood concentrations, offering a non‑invasive way to track ovarian function. A luteal‑phase saliva progesterone threshold of 50 pg/ml and a 1.5‑fold rise over follicular baseline showed good accuracy for confirming ovulation against serum criteria.
The use of saliva and blood progesterone to profile the menstrual cycles of youth professional football players — Ferrer et al., Frontiers in sports and active living
- blood
- saliva
- capillary
- validation
- fertility
- hormones
2024
Fifty-eight matched capillary and venous blood samples collected under official doping control conditions demonstrated excellent laboratory agreement for complete blood count parameters (except platelets) after temperature-monitored air shipment. This validates micro capillary collection as a virtually painless, athlete-friendly alternative to venipuncture for the Athlete Biological Passport, supporting its use in decentralised diagnostics.
Application of micro capillary blood sampling in an anti-doping setting — Lewis et al., Drug testing and analysis (paywalled)
- blood
- capillary
- validation
- venous-agreement
- doping
2024
Self-collected dried blood spots showed high specificity and acceptable sensitivity for detecting islet antibodies compared to serum samples, and participants preferred this method over venous blood draw for its ease and reduced pain.
Feasibility and Validity of In-Home Self-Collected Capillary Blood Spot Screening for Type 1 Diabetes Risk — Sing et al., Diabetes technology & therapeutics (paywalled)
- blood
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
2024
In 30 adult solid organ transplant recipients, capillary blood self-collected using the Tasso+ device showed 91% concordance with venous samples for detecting CMV DNAemia above the limit of detection, with excellent quantitative correlation (Spearman R² = 0.99). Most participants preferred self-collection over venipuncture, suggesting the device could enable decentralised viral monitoring, though sensitivity was lower (95% at 308 IU/mL).
Evaluation of the Tasso+ blood self-collection device for quantitation of plasma cytomegalovirus (CMV) DNAemia in adult solid organ transplant recipients (SOTr) — Phan et al., Microbiology spectrum
- blood
- liquid
- capillary
- self-collection
- validation
- venous-agreement
- acceptability
- serology
2024
Adolescents collecting blood microsamples at home achieved varying success rates across six devices, with Minicollect tubes performing poorest. The confirmation that visual inspection alone was insufficient, by analytical variability, underscores the need for robust quality assessment before deploying any device in decentralised trials.
Self-Sampling by Adolescents at Home: Assessment of the Feasibility to Successfully Collect Blood Microsamples by Inexperienced Individuals — Boffel et al., The AAPS journal (paywalled)
- blood
- liquid
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- self-collection
- acceptability
- pediatric
- dct
2023
A study of 50 paediatric renal transplant recipients found that a validated VAMS LC-MS/MS method for tacrolimus showed high correlation with the reference method over 0.5–60 ng/mL, with minimal haematocrit effect.
Therapeutic Drug Monitoring of Tacrolimus Based on VAMS in Renal Transplant Pediatric Recipients — LC-MS/MS Method, Hematocrit Effect, and Clinical Application — Kocur et al., Pharmaceutics
- vams
- neoteryx-mitra
- blood
- tdm
- haematocrit
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2023
VAMS microsampling found no significant difference from venous blood for tacrolimus in paediatric patients; samples were stable for 14 days, with average difference between paired at-home samples of 0.12 ± 0.94 ng/mL.
VAMS and parallel-reaction-monitoring mass spectrometry for tacrolimus trough measurements at home in paediatric heart-transplant patients — Zhao et al., J. Mass Spectrometry and Advances in the Clinical Lab
- vams
- venous-agreement
- acceptability
- blood
- dbs
- tdm
- self-collection
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2023
VAMS matched serum for the kinase inhibitors nilotinib, cabozantinib, dabrafenib and ruxolitinib, r 0.94–0.97, with serum reliably predictable for the first three, and 93% of at-home samples were collected correctly: at-home VAMS shown feasible for routine cancer-drug monitoring.
Clinical validation and feasibility of VAMS for monitoring of nilotinib, cabozantinib, dabrafenib, trametinib and ruxolitinib — Zimmermann et al., J. Pharmaceutical and Biomedical Analysis (paywalled)
- vams
- venous-agreement
- acceptability
- blood
- tdm
- self-collection
- haematocrit
- dried
- oncology
- capillary
- validation
2023
A UHPLC-HRMS assay quantified 25-hydroxyvitamin D2 and D3 from 20 µL Mitra VAMS samples with accuracy under 10% and precision under 11%, LOQ 5 ng/mL: sensitive enough to flag deficiency and simple enough for untrained self-collection, enabling year-round vitamin-D monitoring.
Quantification of 25-hydroxyvitamin D2 and D3 in Mitra devices (VAMS) by UHPLC-HRMS for regular vitamin D status monitoring — Tuma et al., J. Pharmaceutical and Biomedical Analysis (paywalled)
- vams
- neoteryx-mitra
- blood
- self-collection
- dried
- capillary
- validation
- biomarkers
2023
Capillary VAMS blood covered more of the metabolome than plasma, capturing intracellular red-cell metabolites, and correlated moderately-to-well with venous, Spearman 0.66; the honest caveats are higher finger-prick replicate variability and a need for −80 °C storage within six hours.
VAMS-based blood capillary sampling for mass-spectrometry-based human metabolomics studies — Volani et al., Metabolites
- vams
- venous-agreement
- blood
- metabolome
- dried
- capillary
- validation
- biomarkers
2023
TAP II capillary serum, both professionally collected and self-collected, correlated with venous serum at R > 0.9 for eight analytes including ALT, AST, cholesterol, HDL and triglycerides. Creatinine correlated acceptably but carried a consistent negative bias, and carbon dioxide, potassium and albumin did not reach acceptable agreement: the useful reading is that the panel has to be validated, not the device alone.
Maximizing microsampling: measurement of comprehensive metabolic and lipid panels using a novel capillary blood collection device — Collier et al., The Journal of Applied Laboratory Medicine (paywalled)
- venous-agreement
- blood
- self-collection
- capillary
- bd-microtainer
- liquid
- yourbio
- validation
- biomarkers
2023
Fingerstick blood self-collected into BD Microtainer tubes and posted at ambient temperature for 24 h agreed acceptably with paired serum for 11 of 12 analytes, HbA1c, lipids, creatinine, urea, urate, liver enzymes and total protein, with only AST falling outside limits.
Capillary blood stability and analytical accuracy of 12 analytes stored in Microtainers — Fontaine & Saez, Practical Laboratory Medicine
- blood
- liquid
- capillary
- bd-microtainer
- self-collection
- venous-agreement
- validation
2023
This review evaluates established and emerging capillary blood sampling techniques, comparing factors such as wound geometry and patient comfort, and identifies microneedles as a promising option for paediatric care because they can obtain samples virtually painlessly.
Minimally invasive capillary blood sampling methods — Hoffman et al., Expert review of medical devices (paywalled)
- blood
- capillary
- validation
- acceptability
- pediatric
2023
In 28 healthy adults, alectinib concentrations from capillary microsamples were generally similar to venous ones, which supports the method for therapeutic drug monitoring; the study tested a paediatric-friendly suspension, and the authors point to children, for whom venepuncture is difficult, as the intended use.
Relative bioavailability and food effect study of an oral suspension of alectinib in healthy volunteers using venipuncture and capillary microsampling — Liu et al., Clinical and translational science
- blood
- capillary
- venous-agreement
- pediatric
- tdm
- oncology
2023
A study of 50 paediatric renal transplant recipients found that a UHPLC-MS/MS method successfully quantified mycophenolic acid in VAMS microsampling samples over a 0.10-15 µg/mL range. However, converting microsampling results to plasma equivalents using haematocrit-based regression is required for clinical interpretation, supporting patient-centric decentralised monitoring.
Therapeutic drug monitoring of mycophenolic acid (MPA) using volumetric absorptive microsampling (VAMS) in pediatric renal transplant recipients: ultra-high-performance liquid chromatography-tandem mass spectrometry analytical method development, cross-validation, and clinical application — Kocur et al., Pharmacological reports : PR
- vams
- venous-agreement
- blood
- tdm
- haematocrit
- dried
- capillary
- pediatric
- immunosuppressants
- validation
2023
Self-collection of capillary blood using a topper and paediatric tube was successful for most patients under 70 and showed excellent agreement with venous sampling for PSA measurement, supporting its use for decentralised patient monitoring.
Self-sampling of blood using a topper and pediatric tubes; a prospective feasibility study for PSA analysis using 120 prostate cancer patients — van et al., Clinical chemistry and laboratory medicine (paywalled)
- venous-agreement
- blood
- self-collection
- oncology
- capillary
- liquid
2023
In 26 participants, capillary self-collection with Tasso-SST showed no qualitative discrepancies from venous phlebotomy for SARS-CoV-2 antibody results, and quantitative levels correlated strongly, total Ig Spearman rho 0.72 and IgG 0.85; within the limits of so small a study, this supports at-home collection for serosurveillance.
Comparison of capillary blood self-collection using the Tasso-SST device with venous phlebotomy for anti-SARS-CoV-2 antibody measurement — King et al., Journal of immunological methods (paywalled)
- venous-agreement
- blood
- self-collection
- serology
- capillary
- liquid
2023
A study of 37 kidney transplant recipients found Capitainer and Mitra microsampling feasible for decentralised monitoring. Capitainer showed consistent sampling success, 92%-96%, and higher analytical accuracy than Mitra, 52%-88% success. Proportions within ±15% of venous reference for creatinine and haemoglobin were 92%-100% and 93%-100% for Capitainer, versus 79%-96% and 67%-92% for Mitra, despite small cohorts.
Clinical performance of volumetric finger-prick sampling for the monitoring of tacrolimus, creatinine and haemoglobin in kidney transplant recipients — Vethe et al., British journal of clinical pharmacology (paywalled)
- blood
- capillary
- qdbs
- volumetric
- neoteryx-mitra
- self-collection
- validation
- venous-agreement
- tdm
- immunosuppressants
2023
The Tasso+ capillary blood collection device showed substantial to almost perfect concordance with standard venipuncture for measuring abnormal liver function tests including ALT, ALP, AST and total bilirubin, and patient feedback indicated a very favourable experience, supporting its use for more frequent and convenient testing outside the clinic.
Standard Venipuncture vs a Capillary Blood Collection Device for the Prospective Determination of Abnormal Liver Chemistry — Wickremsinhe et al., The journal of applied laboratory medicine (paywalled)
- blood
- capillary
- validation
- venous-agreement
- acceptability
2023
Dried blood spot eluates showed high agreement with serum for SARS-CoV-2 IgG against Spike and Nucleocapsid (r≈0.96; qualitative φ≈0.98–1.0) and remained stable after 6–8 hours of storage, supporting use of capillary DBS for serosurveys and decentralised testing.
Dried blood spot eluates are suitable for testing of SARS-CoV-2 IgG antibodies targeting Spike protein 1 and Nucleocapsid protein — Guttmann et al., Biochemistry and biophysics reports
- blood
- dried
- capillary
- self-collection
- validation
- venous-agreement
- serology
2023
Capillary finger-stick dried blood spots yielded TSH measurements that agreed strongly with venous plasma (R² 0.988) and correctly identified hypothyroidism and hypothyrotropinemia in most cases. The analyte remained stable for at least four days between -20°C and +30°C, indicating potential for at-home collection in thyroid diagnostics and monitoring.
A Preliminary Analysis of Thyrotropin Measurement from Finger Stick Dried Blood Spot with an Automated High-Throughput Immunoassay Analyzer — Schakelaar et al., Thyroid : official journal of the American Thyroid Association (paywalled)
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- hormones
- haematocrit
2023
The study found that serum concentrations of lacosamide and levetiracetam can be accurately estimated from dried capillary blood samples using simple ratio conversion, with high agreement to measured serum levels, supporting their use in decentralised therapeutic drug monitoring. For lamotrigine, the method is acceptable at low to medium concentrations but less reliable at higher levels, indicating a need for cautious interpretation in clinical practice.
Validation of Conversion Factors for Therapeutic Drug Monitoring of Lacosamide, Lamotrigine, and Levetiracetam in Dried Capillary Blood — Hagemann et al., Therapeutic drug monitoring (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
2023
The study optimised a UHPLC-MS/MS method to measure 11 lipids in 2.74 µL blood microsamples collected with hemaPEN® devices directly from athletes on a track. Five analytes, arachidonic acid, sphingosine, lactic acid, and two lysophosphatidylcholines, showed significant exercise-induced changes, demonstrating that capillary microsampling can reliably capture metabolic responses in decentralised settings without specialist staff.
A targeted UHPLC-MS/MS method to monitor lipidomic changes during a physical effort: Optimization and application to blood microsamples from athletes — Laurent et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- blood
- capillary
- validation
- metabolome
- biomarkers
2023
Capillary blood collected in microtubes yielded HbA1c results that agreed closely with venous sampling, while dried blood spots showed markedly poorer agreement. High patient acceptability and willingness to repeat suggest microtubes are a viable option for decentralised diabetes monitoring.
Home monitoring of haemoglobin A<sub>1c</sub> in diabetes: A systematic review and narrative synthesis on accuracy, reliability and patient acceptability — Colley et al., Diabetic medicine : a journal of the British Diabetic Association (paywalled)
- blood
- liquid
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
2023
Self-collected capillary blood produces serum creatinine results comparable to venous blood, and the analyte remains stable in unspun capillary samples stored at ambient temperature for three days. This supports the use of capillary microsampling for kidney function monitoring in patient-centric, decentralised settings.
Comparability and Stability of Serum Creatinine Concentration in Capillary and Venous Blood — Woolley et al., British journal of biomedical science
- blood
- liquid
- capillary
- validation
- venous-agreement
2023
Capillary blood collected with the Mitra® device showed correlation with venous samples for paclitaxel therapeutic drug monitoring, but wide confidence intervals suggest the methods may not be interchangeable. While plasma and whole blood concentrations were more closely aligned, the variability raises questions about using self-collected capillary samples for dose individualisation without further validation.
Paclitaxel and Therapeutic Drug Monitoring with Microsampling in Clinical Practice — Radovanovic et al., Pharmaceuticals
- blood
- liquid
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- oncology
2023
In 102 samples, quantitative TSH by Finecare LFIA showed strong correlation (r approximately 0.93) and excellent agreement (Cohen's kappa 0.85) with the Roche CobasPro reference; using serum, sensitivity was 90.5% and specificity 96.3% for diagnosing thyroid abnormalities, supporting fingerstick and whole-blood use for decentralised TSH testing.
High-sensitive detection and quantitation of thyroid-stimulating hormone (TSH) from capillary/fingerstick and venepuncture whole-blood using fluorescence-based rapid lateral flow immunoassay (LFIA) — Shurbaji et al., Heliyon
- blood
- liquid
- capillary
- validation
- venous-agreement
- hormones
2023
University branding increased trust and confidence in results, plain packaging promoted discretion, and colour‑coded bags with matching instructions reduced confusion; participants recommended instructional videos, tailored test options, real‑time introductions and personalised reminders to maximise return rates.
Lessons Learned From the Implementation of a Pilot Study on Self-collected Specimen Return by Sexual Minority Men (Project Caboodle!): Qualitative Exploration — Sallabank et al., JMIR formative research
- blood
- urine
- capillary
- self-collection
- acceptability
- sti
2023
The study demonstrated that qPCR-based epigenetic immune cell counting from capillary dried blood spots agreed with venous blood and conventional flow cytometry in healthy donors, and then identified lymphopenia, neutrophilia and a lowered lymphocyte-to-neutrophil ratio in 103 COVID-19 patients versus 113 healthy controls, with naive B cell frequency tracking disease severity, suggesting that filter-paper blood collection could enable remote immune monitoring in home-isolated patients.
Epigenetic immune monitoring for COVID-19 disease course prognosis — Samans et al., Frontiers in immunology
- blood
- liquid
- dried
- capillary
- validation
- venous-agreement
- serology
2023
In kidney transplant recipients, home capillary blood self-testing of creatinine using a handheld analyser showed good agreement with clinic venous laboratory results, whereas potassium showed poorer agreement; patient self-use of the device was not a significant source of the potassium difference.
Patient Self-Testing of Kidney Function at Home, a Prospective Clinical Feasibility Study in Kidney Transplant Recipients — Murray et al., Kidney international reports
- blood
- liquid
- capillary
- self-collection
- venous-agreement
2023
A UHPLC-MS/MS method for measuring Fabry disease biomarkers in dried blood spots was validated using both conventional cards and Capitainer B devices. Capillary blood gave similar results to venous blood across a wide haematocrit range, supporting decentralised screening and longitudinal monitoring of patients.
Mass Spectrometry Analysis of Globotriaosylsphingosine and Its Analogues in Dried Blood Spots — Boutin et al., International journal of molecular sciences
- blood
- dried
- capillary
- dbs
- validation
- venous-agreement
- haematocrit
- biomarkers
2023
The authors developed a capillary microfluidic device that captures multiple blood biomarkers at collection and dries them on-chip, enabling safe shipment to centralised laboratories for multiplexed analysis. This patient-centric approach could support remote health monitoring and decentralised trials.
Microfluidic Device for Patient-Centric Multiplexed Assays with Readout in Centralized Laboratories — Hauser et al., Analytical chemistry
- blood
- dried
- capillary
- dct
- biomarkers
2023
In participants 11 months after SARS-CoV-2 infection, the nano-immunoassay achieved 98.33% sensitivity and 97.62% specificity on venous serum. When combined with dried capillary microsampling, sensitivity was 95.05% with Mitra, 61.11% with repurposed glucose strips and 83.16% with HemaXis (91.49% after automated extraction), with no loss of specificity, supporting home-based sampling for serology.
Clinical sensitivity and specificity of a high-throughput microfluidic nano-immunoassay combined with capillary blood microsampling for the identification of anti-SARS-CoV-2 Spike IgG serostatus — Michielin et al., PloS one
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- serology
2023
VAMS finger-prick microsampling showed reliable agreement with venous blood sampling for measuring tacrolimus and creatinine after correction for systematic differences, supporting its use in therapeutic drug monitoring. This offers a patient-centric, decentralised alternative to frequent venipunctures in kidney transplant recipients.
Serum Creatinine and Tacrolimus Assessment With VAMS Finger-Prick Microsampling: A Diagnostic Test Study — Scuderi et al., Kidney medicine
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- immunosuppressants
2023
The authors validated a UHPLC-MS/MS method for quantifying four ceramide species in 10 μL quantitative dried blood spots. Ceramides remained stable at room temperature, supporting remote self-collection, and concentrations were higher in fingertip whole blood than in plasma or serum, which is relevant for at-home monitoring of cardiovascular and metabolic disease risk.
Ceramides biomarkers determination in quantitative dried blood spots by UHPLC-MS/MS — Meikopoulos et al., Analytica chimica acta (paywalled)
- blood
- dried
- capillary
- qdbs
- validation
- metabolome
- biomarkers
2023
Capillary blood in Hem-Col microtubes showed a relative bias of 1.23% against directly processed venous sampling for CEA, with samples remaining stable for up to four days after withdrawal. Home-based CEA monitoring for colorectal cancer follow-up is feasible with this method, though underfilled tubes flagged by high lithium concentrations yield less reliable results.
Reliable capillary sampling of carcinoembryonic antigen at home: the CASA feasibility study — Voigt et al., Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland (paywalled)
- blood
- liquid
- capillary
- self-collection
- validation
- venous-agreement
- colorectal
2023
Capillary blood self-collection showed acceptable agreement with venous samples for vitamin D, C-reactive protein and alkaline phosphatase even after 36-hour delays, but calcium and phosphate levels were more affected by pre-analytical conditions. This supports decentralised serology and biomarker testing while highlighting analytes that need tighter pre-analytical control.
Concordance in COVID-19 serology, bone mineralization, and inflammatory analytes between venous and self-collected capillary blood samples exposed to various pre-analytical conditions — Hosseini et al., Annals of clinical biochemistry (paywalled)
- blood
- liquid
- capillary
- validation
- venous-agreement
- serology
- biomarkers
2023
The TASSO-M20 device for self-collected capillary blood demonstrated strong agreement with liquid whole blood for phosphatidylethanol (PEth) measurement (r²=0.988) and proved feasible and acceptable during virtual alcohol monitoring, causing less discomfort than finger stick methods. In a single participant tracked over time, PEth levels from the device aligned with urinary ethyl glucuronide and self-reported alcohol consumption.
Validation of the quantification of phosphatidylethanol 16:0/18:1 concentrations in TASSO-M20 devices — Jett et al., Alcohol, clinical & experimental research (paywalled)
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- acceptability
2023
Targeted DNA methylation analysis accurately estimated relative and absolute leukocyte subset counts from dried capillary blood collected with Mitra devices, showing strong correlation with conventional venous blood methods (r=0.72–0.97). This enables self-sampling by finger prick, facilitating easier access to leukocyte testing for patients with haematological disorders.
Targeted DNA Methylation Analysis Facilitates Leukocyte Counts in Dried Blood Samples — Hubens et al., Clinical chemistry (paywalled)
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- venous-agreement
- biomarkers
2023
In adult kidney transplant patients, fingerprick VAMS and dried blood spot microsampling achieved accurate simultaneous measurement of tacrolimus, mycophenolic acid, and prednisolone compared with venepuncture. The authors noted an overall preference for VAMS over conventional dried blood spots.
Fingerprick Microsampling Methods Can Replace Venepuncture for Simultaneous Therapeutic Drug Monitoring of Tacrolimus, Mycophenolic Acid, and Prednisolone Concentrations in Adult Kidney Transplant Patients — Scuderi et al., Therapeutic drug monitoring (paywalled)
- blood
- dried
- capillary
- vams
- dbs
- neoteryx-mitra
- validation
- venous-agreement
- tdm
- immunosuppressants
2023
Microsampling assays for immunosuppressant monitoring showed three- to fourfold higher imprecision across 14 laboratories than conventional whole-blood analysis, with coefficients of variation of 11.7 to 18.6 percent versus 3.9 to 4.9 percent. In a patient specimen, this analytical scatter produced a different clinical decision, proving that current microsampling practice lacks the standardisation required for safe home-based therapeutic drug monitoring.
Results From a Proficiency Testing Pilot for Immunosuppressant Microsampling Assays — Veenhof et al., Therapeutic drug monitoring
- blood
- dried
- capillary
- vams
- neoteryx-mitra
- validation
- tdm
- immunosuppressants
2023
Finger-stick capillary blood spotted onto filter paper and dried (DBS) provides C-reactive protein results that correlate excellently with venous plasma (R² = 0.986). The method correctly classified all 25 high cardiovascular-risk patients and 12 of 13 inflammation cases, with analyte stability demonstrated for 31 days, supporting its use for patient-centric at-home sampling in decentralised diagnostics and screening programmes.
Analysis of C-reactive protein from finger stick dried blood spot to predict high risk of cardiovascular disease — Schakelaar et al., Scientific reports
- blood
- dried
- capillary
- dbs
- self-collection
- validation
- venous-agreement
- haematocrit
- biomarkers
2023
A method for tacrolimus quantification from volumetric dried blood spots collected with a hemaPEN device was validated using automated LC-MS/MS extraction. The assay was linear from 1 to 100 µg/L and met all analytical and clinical validation criteria, enabling decentralised therapeutic drug monitoring of immunosuppressants through home-based capillary blood sampling.
New perspectives for the therapeutic drug monitoring of tacrolimus: Quantification in volumetric DBS based on an automated extraction and LC-MS/MS analysis — Rosé et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled)
- blood
- dried
- capillary
- dbs
- volumetric
- validation
- tdm
- immunosuppressants
2023
Volumetric dried blood spots from finger-prick correlated strongly with venous serum lithium concentrations (Pearson’s R=0.95, ratio 0.78) in thirty-nine patients. This patient-centric microsampling method could enable home-based therapeutic drug monitoring for bipolar disorder, improving compliance and safety where venous sampling is impractical.
Determination of lithium concentration in capillary blood using volumetric dried blood spots — Wikström et al., Journal of pharmaceutical and biomedical analysis (paywalled)
- blood
- dried
- capillary
- dbs
- volumetric
- self-collection
- venous-agreement
- tdm
2023
Capillary blood yields comparable results to venous blood for common biochemistry and haematology parameters on routine analysers, but performance may degrade if samples are not processed within 24 hours.
Analysis of common biomarkers in capillary blood in routine clinical laboratory. Preanalytical and analytical comparison with venous blood — Maroto-García et al., Diagnosis (paywalled)
- blood
- liquid
- capillary
- validation
- venous-agreement
2023
In healthy adults, capillary blood collected with the Onflow device yielded similar chemistry results to venous blood and was rated more acceptable with lower pain than venepuncture, with high willingness to reuse and positive phlebotomist usability.
Painless Capillary Blood Collection: A Rapid Evaluation of the Onflow Device — Noble et al., Diagnostics
- blood
- liquid
- capillary
- venous-agreement
- acceptability
2023
Deprez et al. validated LC‑MS/MS methods for four immunosuppressants and creatinine from a single 10 μL quantitative dried blood spot. With biases under 10 % and CVs below 8 %, the approach enables accurate patient‑centric therapeutic drug monitoring from capillary blood at home, mitigating the haematocrit effect through volumetric collection.
Liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring of immunosuppressants and creatinine from a single dried blood spot using the Capitainer® qDBS device — Deprez et al., Analytica chimica acta (paywalled)
- blood
- dried
- capillary
- qdbs
- volumetric
- validation
- tdm
- immunosuppressants
- haematocrit
2022
The paper records that the TAP II devices used for the infant draws were provided by YourBio Health, and that capillary serum was collected from babies as young as two months: the smallest patients sampled, without a heel prick or a venepuncture.
Durability of anti-spike antibodies in infants after maternal COVID-19 vaccination or natural infection — Shook, Edlow et al., JAMA
- blood
- liquid
- yourbio
- capillary
- pediatric
- serology
2022
Patients self-collected upper-arm capillary blood with press-activated devices including TAP II; autoantibody and CRP results agreed with venous at r≥0.98, were rated less painful, and 98.6% got enough blood within two attempts.
Remote self-collection of upper-arm capillary blood for autoantibody analysis in immune-mediated rheumatic diseases — Zarbl et al., RMD Open
- venous-agreement
- acceptability
- blood
- self-collection
- capillary
- liquid
- yourbio
- biomarkers
2022
Capillary self-sampling gave CRP and autoantibody values nearly identical to venous, ICC 0.97–0.998, was less painful, and the upper-arm route drew far higher acceptance and willingness to sample at home.
Accuracy and tolerability of capillary self-sampling for inflammation and autoantibodies in rheumatoid arthritis: a randomized controlled trial — Knitza et al., Arthritis Research & Therapy
- blood
- liquid
- capillary
- self-collection
- venous-agreement
- acceptability
2022
In British Columbia, finger-prick dried blood spots had 97% specificity and 79% sensitivity for SARS-CoV-2 antibodies in unvaccinated groups, rising to 97 to 100% after vaccination, against serum; limited to one jurisdiction, the results support decentralised serosurveillance with self-collected dried blood spots.
Performance of Immunoglobulin G Serology on Finger Prick Capillary Dried Blood Spot Samples to Detect a SARS-CoV-2 Antibody Response — Nikiforuk et al., Microbiology spectrum
- venous-agreement
- blood
- dbs
- dried
- serology
- capillary
- pediatric
2022
The TAP device showed near perfect agreement with venous sampling for anti-Müllerian hormone measurements, with higher accuracy and lower pain compared to ADx card. This validates TAP as a reliable option for patient-led fertility hormone testing at home.
Evaluation of at-home serum anti-Müllerian hormone testing: a head-to-head comparison study — Silliman et al., Reproductive biology and endocrinology : RB&E
- blood
- capillary
- yourbio
- venous-agreement
- acceptability
- fertility
- hormones
Read from the corpus on .