  1. 2024

    A decentralised trial in Singapore found 97% participant retention and high sample collection rates. Participants reported convenience and safety, while reduced travel lowered environmental impact compared to traditional trials.

    Decentralized clinical trials are better for the participants and for the planet: the case study of a double-blind randomized controlled trial in Singapore (PROMOTE study)Fries et al., Frontiers in public health

    • dct
    • acceptability
  2. 2024

    Capillary sampling for carcinoembryonic antigen showed near perfect agreement with venous results and was preferred by most participants, supporting reliable home based collection that could reduce hospital visits.

    Feasibility, reliability and satisfaction of (automated) capillary carcinoembryonic antigen measurements for future home-based blood sampling: the prospective CASA-I studyVoigt et al., Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland (paywalled)

    • venous-agreement
    • acceptability
    • blood
    • self-collection
    • oncology
    • colorectal
    • capillary
    • yourbio
  3. 2024

    Capillary finger prick sampling at home showed close agreement with venous sampling for measuring infliximab, vedolizumab and CRP, with no systematic bias and high patient tolerability and practicality, supporting decentralised monitoring of biologic therapy in IBD.

    Clinical Validation of a Capillary Blood Home-Based Self-Sampling Technique for Monitoring of Infliximab, Vedolizumab, and C-Reactive Protein Concentrations in Patients With Inflammatory Bowel DiseaseOtten et al., Inflammatory bowel diseases

    • blood
    • liquid
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
    • tdm
    • biologics
  4. 2024

    Primary caregivers of children with metabolic disorders found at-home dried blood spot collection acceptable after training, which could enable more timely and cost-effective monitoring. This supports the feasibility of decentralised, patient-centric sampling for long-term condition management.

    Acceptability of dried blood spot collection by primary caregivers of Filipino patients with maple syrup urine disease (MSUD) and phenylketonuria (PKU)Merencilla et al., Journal of community genetics (paywalled)

    • acceptability
    • blood
    • dbs
    • self-collection
    • dried
    • pediatric
  5. 2024

    Preliminary data from the HOT4PrEP trial show 67% of participants offered home-based PrEP monitoring chose to self-collect blood and STI samples at home, and 82% of these successfully returned kits. This demonstrates feasibility and acceptability of decentralised microsampling for HIV prevention, which may improve PrEP retention and expand clinical capacity.

    Implementation and Evaluation of a Home-Based Pre-Exposure Prophylaxis Monitoring Option: Protocol for a Randomized Controlled TrialCannon et al., JMIR research protocols

    • blood
    • self-collection
    • acceptability
    • dct
    • sti
  6. 2024

    Transgender women in Uganda initially anxious about point-of-care urine tenofovir testing for PrEP adherence monitoring found it acceptable after counselling, though test interpretation caused confusion as two lines indicated non-adherence rather than positivity as with HIV self-tests. Some participants avoided clinic visits to prevent detection of non-adherence, a behaviour termed 'white coat dosing', highlighting the need for tailored adherence strategies in this population.

    Urine tenofovir testing for real-time PrEP adherence feedback: a qualitative study involving transgender women in UgandaMujugira et al., Journal of the International AIDS Society

    • urine
    • self-collection
    • acceptability
    • tdm
  7. 2024

    In a 14-day study of youth with neurodevelopmental conditions and chronic pain, multimodal in-home monitoring achieved good accelerometer wear compliance (77% wore devices for at least 7 days) and moderate survey engagement, but adherence to salivary cortisol sampling was low at 28% after excluding protocol violations and dry swabs. Families reported high overall satisfaction and willingness to participate again, highlighting that remote sampling protocols in pediatric populations require iterative tailoring to improve biospecimen collection adherence.

    The Living Lab at Home: Feasibility and Acceptability of Multimodal In-Home Data Collection Among Youth Across the Developmental SpectrumBoerner et al., Journal of developmental and behavioral pediatrics : JDBP

    • saliva
    • self-collection
    • acceptability
    • pediatric
    • cortisol
    • wearable
    • actigraphy
    • multimodal
  8. 2024

    A feasibility study at a Kathmandu maternity hospital showed newborn metabolic screening using dried blood spots achieved 98.8% parental consent, driven primarily by cost-free participation. Despite pandemic-related transport delays to a central Indian laboratory, results were delivered within two weeks, detecting metabolic abnormalities in 13 of 825 infants, with 90% of healthcare providers endorsing routine implementation.

    Feasibility of clinical newborn metabolic screening in a high-volume maternity center in NepalKhan et al., BMC global and public health

    • blood
    • dried
    • dbs
    • acceptability
    • pediatric
  9. 2024

    This systematic review of 67 studies involving 34,739 kidney disease patients found dried blood microsampling was mainly used for immunosuppressant therapeutic drug monitoring and kidney function assessment. The approach offered cost savings, was preferred by patients for home self-collection, and provides a patient-centric opportunity to upscale longitudinal sampling and reduce participation bias in decentralised kidney disease research.

    A Systematic Literature Review on the Use of Dried Biofluid Microsampling in Patients With Kidney DiseaseLamond et al., Journal of clinical laboratory analysis

    • blood
    • dried
    • capillary
    • self-collection
    • validation
    • acceptability
    • tdm
    • immunosuppressants
    • economics
  10. 2024

    Postpartum women with HIV who had low ART drug concentrations reported more challenges with HIV status disclosure, social support, health system interactions and health beliefs compared with those who had continuously high concentrations; integrating objective adherence biomarkers with patient narratives could enable real time interventions to improve ART adherence and maternal infant outcomes.

    Antiretroviral therapy adherence among peripartum women with HIV in Kenya: an explanatory mixed methods study using dry blood spot measures and narrative interviewsHampanda et al., AIDS care (paywalled)

    • blood
    • dried
    • dbs
    • acceptability
    • tdm
  11. 2024

    Using Saliva Children's Swabs to collect salivary alpha-amylase and cortisol was feasible in elderly nursing home residents with dementia, though active patient engagement remained necessary. However, an individualised music listening intervention showed no significant effect on these salivary stress markers.

    Salivary cortisol and alpha-amylase as stress markers to evaluate an individualized music intervention for people with dementia: feasibility and pilot analysesHillebrand et al., BMC research notes

    • saliva
    • acceptability
    • hormones
    • cortisol
    • biomarkers
  12. 2024

    The study found low SARS-CoV-2 seropositivity in unvaccinated children and young adults in British Columbia, with higher rates in South Asian participants and young infants. Many infections were undetected, highlighting the value of patient-centric microsampling for more accurate, decentralised surveillance.

    Factors associated with SARS-CoV-2 infection in unvaccinated children and young adultsSilverberg et al., BMC infectious diseases

    • blood
    • dried
    • dbs
    • acceptability
    • pediatric
    • serology
  13. 2024

    Microsampling with Mitra® devices correlated strongly with venous plasma for capecitabine therapeutic drug monitoring (r=0.97), but yielded consistently lower concentrations. Patients preferred this method and reported minimal pain, suggesting it is suitable for patient-centric oncology drug monitoring in decentralised settings.

    Comparison of capecitabine concentrations determined by microsampling versus plasma concentrations for therapeutic drug monitoring: a pilot studyShafiei et al., The Journal of pharmacy and pharmacology (paywalled)

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • acceptability
    • tdm
    • oncology
  14. 2024

    Plasma separation cards showed high specificity (99.3%) but moderate sensitivity (87.5%) against EDTA-plasma for HIV-1 viral load monitoring at a 1,000 copies/ml threshold in a South African cohort. Despite favourable usability among healthcare workers, laboratory-reported technical difficulties must be addressed to enable reliable decentralised scale-up in resource-constrained settings.

    Assessment of the performance of the plasma separation card for HIV-1 viral load monitoring in South AfricaChimoyi et al., Journal of clinical microbiology

    • blood
    • dried
    • capillary
    • validation
    • venous-agreement
    • acceptability
    • pediatric
    • serology
  15. 2024

    Fourteen of 15 under-screened women said they would be more likely to participate in cervical screening if they could self-collect samples, indicating that self-sampling could improve uptake among those who rarely or never attend screening.

    Experiences and Perceptions of Cervical Cancer Screening Using Self-Sampling among Under-Screened Women in FlandersBuelens et al., Healthcare

    • urine
    • self-collection
    • acceptability
    • hpv
  16. 2024

    Urinary HPV testing offers comparable detection to cervical samples and high patient acceptability, making it a viable noninvasive option for decentralised cervical cancer screening and vaccine surveillance. However, the absence of standardised protocols for sample collection and processing currently limits its widespread clinical adoption.

    A review of urinary HPV testing for cervical cancer management and HPV vaccine surveillance: rationale, strategies, and limitationsCheng et al., European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology (paywalled)

    • urine
    • self-collection
    • validation
    • acceptability
    • hpv
    • sti
  17. 2024

    An online service that mailed saliva self-sampling kits to 4623 GBMSM and trans women achieved a 67.5% return rate, detected 2.45% HIV prevalence with 100% linkage to care, and was recommended by 98% of participants, proving feasibility for decentralised screening.

    An Online HIV Self-Sampling Strategy for Gay, Bisexual and Other Men Who Have Sex with Men and Trans Women in SpainMartínez-Riveros et al., Journal of community health

    • saliva
    • self-collection
    • acceptability
    • serology
    • sti
  18. 2024

    The Tasso+ device, which uses a vacuum to collect capillary blood from the upper arm, gathered an average of 536 microlitres of whole blood from 47 men who have sex with men using PrEP, with 91% of samples sufficient for HIV testing and 89% for syphilis testing. Acceptability was high, with 87% expressing a positive attitude and 77% willing to use the device again for home self-sampling.

    Using an Innovative Method for Self-Collection of Capillary Blood for HIV and Syphilis Testing Among Men Who Have Sex With Men Who Use Pre-exposure Prophylaxis in the Netherlands; Limburg4zeroGoense et al., Sexually transmitted diseases (paywalled)

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • acceptability
    • serology
    • sti
  19. 2024

    Capillary blood collection using liquid and dried microsampling devices yielded pharmacokinetic profiles comparable to venous sampling for two monoclonal antibodies and a small molecule, whereas haematocrit correction was necessary for dried formats and bridging was ineffective for hydroxychloroquine. The findings demonstrate the bioanalytical feasibility and patient acceptability of remote microsampling tools for pharmacokinetic evaluations in decentralised clinical trials.

    Evaluation of Patient-Centric Sample Collection Technologies for Pharmacokinetic Assessment of Large and Small MoleculesMandlekar et al., Clinical pharmacology and therapeutics (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • neoteryx-mitra
    • validation
    • venous-agreement
    • acceptability
    • tdm
    • biologics
    • dct
    • haematocrit
  20. 2024

    First-void urine testing detected HPV with 87% sensitivity and 89% specificity, and participants reported feeling comfortable with this self-collection method. This approach could improve uptake of cervical cancer screening in decentralised settings.

    The Impact of Urine-Sample HPV Testing on the Effectiveness of Screening for Cervical Cancer: An Umbrella ReviewMiazga et al., Cancers

    • urine
    • first-void
    • self-collection
    • validation
    • acceptability
    • hpv
  21. 2024

    Flexibility of location and time were the most motivating factors for people with type 2 diabetes to participate in decentralised clinical trials. Digital infrastructure, literacy, home visits, personal interaction, and healthcare professional relationships could be either enablers or barriers depending on individual preferences, suggesting these must be addressed in trial design.

    What motivates people with type 2 diabetes mellitus to participate in clinical trials from home?Kopanz et al., Clinical and translational science

    • acceptability
    • dct
  22. 2024

    The study found that DBS testing showed high specificity for HIV, HBV and HCV and perfect sensitivity for HIV and HBV, but lower sensitivity for syphilis and HCV, with creatinine measurements slightly higher than venous samples. Despite challenges in sample adequacy, DBS was acceptable to participants and could support decentralised STI and renal monitoring in men who have sex with men.

    Use of Home-Based Self-Collected Dried Blood Spots to Test for Syphilis, Human Immunodeficiency Virus, Hepatitis C and B Virus Infections and Measuring Creatinine ConcentrationNieuwenburg et al., Sexually transmitted diseases

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
    • serology
    • sti
  23. 2024

    Self-collected saliva without additives showed comparable diagnostic performance to nasopharyngeal swabs for SARS-CoV-2 detection, with 87.6% sensitivity and 99.6% specificity. The sample remained stable for 72 hours and was deemed acceptable by both patients and staff, supporting its use in decentralised, patient-centric screening programmes.

    Diagnostic performance, stability, and acceptability of self-collected saliva without additives for SARS-CoV-2 molecular diagnosisMarín-Echeverri et al., European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology (paywalled)

    • saliva
    • self-collection
    • validation
    • acceptability
    • serology
  24. 2024

    This review of remote HbA1c testing via capillary blood microsampling finds that both dried and liquid formats can produce results comparable to venous sampling when collection, stability and extraction are properly validated. It matters because self-collected microsamples could enable decentralised diabetes monitoring and telemedicine, but heterogeneity in study designs and methods must be resolved before reliable implementation.

    Remote HbA<sub>1c</sub> testing via microsampling: fit for purpose?Verougstraete et al., Clinical chemistry and laboratory medicine (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  25. 2024

    The Xpert CT/NG assay showed high specificity and moderate-to-high sensitivity for chlamydia and gonorrhoea in urine and rectal specimens, though pharyngeal sensitivity was lower. High acceptability among men who have sex with men and rapid turnaround support its use for decentralised STI screening with immediate treatment initiation.

    Clinic-based evaluation of the dual Xpert CT/NG assay on the GeneXpert System for screening for extragenital chlamydial and gonococcal infections amongst men who have sex with menCordioli et al., BMC infectious diseases

    • urine
    • first-void
    • validation
    • acceptability
    • sti
  26. 2024

    In a qualitative study of 100 service users, online postal self-sampling for STIs was valued for privacy and for overcoming barriers such as limited clinic appointments, although blood self-sampling proved challenging for most participants. Users favoured retaining clinic access for broader sexual health support, indicating that decentralised testing works best as part of a hybrid model rather than a complete replacement.

    How does online postal self-sampling (OPSS) shape access to testing for sexually transmitted infections (STIs)? A qualitative study of service usersSpence et al., BMC public health

    • blood
    • self-collection
    • acceptability
    • sti
  27. 2024

    Self-collection of saliva for cortisol awakening response research at home was experienced as arduous, with participants reporting apprehension, cognitive burden, and disruption to sleep and morning routines. Difficulty identifying the moment of awakening affected sample timing, though habituation reduced these effects over repeated days, indicating that clear protocols are needed to improve ecological validity in decentralised hormone monitoring.

    <b>Experiences of participating in cortisol awakening response research:</b> <i>"I was more conscious</i> <i>than usual, I wanted to get it right</i> <i>"</i>Ramachandran et al., Comprehensive psychoneuroendocrinology

    • saliva
    • self-collection
    • acceptability
    • hormones
    • cortisol
  28. 2024

    Among 1,423 people who use drugs across 21 community centres, a decentralised care programme using dried blood spot testing achieved a 93% cure rate in those who completed hepatitis C therapy and were monitored. Over 90% of participants accepted the decentralised screening and treatment approach, showing patient-centric microsampling can improve healthcare access for stigmatised populations.

    Implementing a new HCV model of care for people who use drugsHerranz Mochales et al., JHEP reports : innovation in hepatology

    • blood
    • dried
    • dbs
    • acceptability
    • dct
    • serology
  29. 2024

    A graphene lab-on-a-chip device achieved high accuracy and precision for multiplex renal biomarker testing in serum and saliva, with sensitivities ranging from 89.0 to 99.7 per cent. Untrained volunteers produced results comparable to trained chemists, suggesting the device is suitable for patient-centric at-home diagnostics and could improve access to chronic kidney disease monitoring.

    Noninvasive and Multiplex Self-Test of Kidney Disease Biomarkers with Graphene-Based Lab-on-a-Chip (G-LOC): Toward Digital Diagnostics in the Hands of PatientsDiforti et al., Analytical chemistry (paywalled)

    • saliva
    • self-collection
    • validation
    • acceptability
    • biomarkers
  30. 2024

    Most women were confident using vaginal self-sampling kits and trusted the results, with 71 percent preferring self-sampling over clinician-collected tests for future screening. However, preferences varied by ethnicity and prior screening status, and a significant minority preferred urine-based tests, suggesting that offering choice between sampling methods will improve uptake in decentralised cervical screening programmes.

    Experiences of Self-Sampling and Future Screening Preferences in Non-Attenders Who Returned an HPV Vaginal Self-Sample in the YouScreen Study: Findings From a Cross-Sectional QuestionnaireDrysdale et al., Health expectations : an international journal of public participation in health care and health policy

    • self-collection
    • acceptability
    • hpv
  31. 2024

    Self-collected dried blood spots showed high specificity and acceptable sensitivity for detecting islet antibodies compared to serum samples, and participants preferred this method over venous blood draw for its ease and reduced pain.

    Feasibility and Validity of In-Home Self-Collected Capillary Blood Spot Screening for Type 1 Diabetes RiskSing et al., Diabetes technology & therapeutics (paywalled)

    • blood
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  32. 2024

    In 30 adult solid organ transplant recipients, capillary blood self-collected using the Tasso+ device showed 91% concordance with venous samples for detecting CMV DNAemia above the limit of detection, with excellent quantitative correlation (Spearman R² = 0.99). Most participants preferred self-collection over venipuncture, suggesting the device could enable decentralised viral monitoring, though sensitivity was lower (95% at 308 IU/mL).

    Evaluation of the Tasso+ blood self-collection device for quantitation of plasma cytomegalovirus (CMV) DNAemia in adult solid organ transplant recipients (SOTr)Phan et al., Microbiology spectrum

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • serology
  33. 2024

    Older adults achieved 98% adherence when self-collecting dried blood spots at home for inflammatory markers, with 97% of samples yielding valid results. Test-retest reliability was good (ICCs 0.70–0.76) and correlation with venous blood was strong (r=0.60–0.99), demonstrating that remote capillary sampling is a feasible and valid method for decentralised assessment of inflammation in older adults.

    Remote dried blood spot collection for inflammatory markers in older adults is feasible, reliable, and validReed et al., Brain, behavior, and immunity (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • biomarkers
  34. 2024

    A systematic review of 70 studies found that 94.7% of accuracy studies reported comparable sensitivity and specificity between self-sampling and clinician collection for HPV detection, with patient acceptability ranging from 84.2% to 100% for devices including Colli-Pee. This evidence endorses decentralised cervical screening to improve uptake.

    Comparison of diagnostic accuracy and acceptability of self-sampling devices for human Papillomavirus detection: A systematic reviewAimagambetova et al., Preventive medicine reports

    • urine
    • first-void
    • colli-pee
    • self-collection
    • validation
    • acceptability
    • hpv
  35. 2024

    Adolescents collecting blood microsamples at home achieved varying success rates across six devices, with Minicollect tubes performing poorest. The confirmation that visual inspection alone was insufficient, by analytical variability, underscores the need for robust quality assessment before deploying any device in decentralised trials.

    Self-Sampling by Adolescents at Home: Assessment of the Feasibility to Successfully Collect Blood Microsamples by Inexperienced IndividualsBoffel et al., The AAPS journal (paywalled)

    • blood
    • liquid
    • dried
    • capillary
    • vams
    • dbs
    • neoteryx-mitra
    • self-collection
    • acceptability
    • pediatric
    • dct
  36. 2024

    First-void urine collected with the Colli-pee device detected high-grade cervical precancer with 90.3% sensitivity, substantially better than the 73.4% sensitivity of standard-pot urine, and was acceptable to colposcopy attendees. The device achieved 92% relative sensitivity compared with clinician-collected cervical samples, showing promise for decentralised HPV screening.

    Urine high-risk human papillomavirus testing as an alternative to routine cervical screening: A comparative diagnostic accuracy study of two urine collection devices using a randomised study design trialDavies et al., BJOG : an international journal of obstetrics and gynaecology (paywalled)

    • urine
    • first-void
    • colli-pee
    • self-collection
    • acceptability
    • hpv
    • sti
  37. 2023

    A systematic review of 13 decentralised studies: 11 reported recruitment success with approaches departing from site-based methods, and 7 reported success retaining participants. The recruitment finding largely reflects remote outreach rather than remote sampling specifically.

    Methods and perceptions of success for patient recruitment in decentralized clinical studiesMiyata et al., Journal of Clinical and Translational Science

    • dct
    • acceptability
  38. 2023

    VAMS microsampling found no significant difference from venous blood for tacrolimus in paediatric patients; samples were stable for 14 days, with average difference between paired at-home samples of 0.12 ± 0.94 ng/mL.

    VAMS and parallel-reaction-monitoring mass spectrometry for tacrolimus trough measurements at home in paediatric heart-transplant patientsZhao et al., J. Mass Spectrometry and Advances in the Clinical Lab

    • vams
    • venous-agreement
    • acceptability
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
    • pediatric
    • immunosuppressants
    • validation
  39. 2023

    VAMS matched serum for the kinase inhibitors nilotinib, cabozantinib, dabrafenib and ruxolitinib, r 0.94–0.97, with serum reliably predictable for the first three, and 93% of at-home samples were collected correctly: at-home VAMS shown feasible for routine cancer-drug monitoring.

    Clinical validation and feasibility of VAMS for monitoring of nilotinib, cabozantinib, dabrafenib, trametinib and ruxolitinibZimmermann et al., J. Pharmaceutical and Biomedical Analysis (paywalled)

    • vams
    • venous-agreement
    • acceptability
    • blood
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • capillary
    • validation
  40. 2023

    This review evaluates established and emerging capillary blood sampling techniques, comparing factors such as wound geometry and patient comfort, and identifies microneedles as a promising option for paediatric care because they can obtain samples virtually painlessly.

    Minimally invasive capillary blood sampling methodsHoffman et al., Expert review of medical devices (paywalled)

    • blood
    • capillary
    • validation
    • acceptability
    • pediatric
  41. 2023

    The Tasso+ capillary blood collection device showed substantial to almost perfect concordance with standard venipuncture for measuring abnormal liver function tests including ALT, ALP, AST and total bilirubin, and patient feedback indicated a very favourable experience, supporting its use for more frequent and convenient testing outside the clinic.

    Standard Venipuncture vs a Capillary Blood Collection Device for the Prospective Determination of Abnormal Liver ChemistryWickremsinhe et al., The journal of applied laboratory medicine (paywalled)

    • blood
    • capillary
    • validation
    • venous-agreement
    • acceptability
  42. 2023

    In a survey of 88 young people assigned female at birth, 69% preferred at-home self-collection for gonorrhoea and chlamydia screening, and lower educational attainment was associated with reduced preference, suggesting that at-home sampling is broadly acceptable but may need tailored support to address educational and other social determinants.

    At-Home Self-Collection of Urine or Vaginal Samples for Gonorrhea and Chlamydia Screening Among Young People Who Were Assigned Female at BirthChongsuwat & Cody, AJPM focus

    • urine
    • self-collection
    • acceptability
    • sti
  43. 2023

    A remote protocol combining daily surveys with weekly self-collected dried blood spots achieved a 92% study completion rate and high acceptability among reproductive-age women smokers, with 87% of participants collecting most samples and the same proportion extremely willing to repeat the study. This feasibility demonstrates that decentralised microsampling can support longitudinal research on hormonal contraceptive effects and smoking behaviour.

    Feasibility of remotely assessing hormonal contraceptive use and smoking-related symptomatology: Evidence from a preliminary prospective cohort studyMedvescek & Allen, Drug and alcohol dependence reports (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • acceptability
    • fertility
    • hormones
    • dct
  44. 2023

    Fertility patients commonly use direct-to-consumer ovulation prediction methods, yet reproductive endocrinologists rate the utility of these tests substantially lower than patients do. This discordance highlights the need for better patient education and guidelines to inform self-collection and interpretation of fertility biomarkers in decentralised care.

    Direct-to-consumer fertility testing: utilization and perceived utility among fertility patients and reproductive endocrinologistsPeipert et al., Reproductive biomedicine online (paywalled)

    • self-collection
    • acceptability
    • fertility
    • hormones
  45. 2023

    Capillary blood collected in microtubes yielded HbA1c results that agreed closely with venous sampling, while dried blood spots showed markedly poorer agreement. High patient acceptability and willingness to repeat suggest microtubes are a viable option for decentralised diabetes monitoring.

    Home monitoring of haemoglobin A<sub>1c</sub> in diabetes: A systematic review and narrative synthesis on accuracy, reliability and patient acceptabilityColley et al., Diabetic medicine : a journal of the British Diabetic Association (paywalled)

    • blood
    • liquid
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  46. 2023

    Dried blood spot sampling shows moderate agreement with plasma for therapeutic drug monitoring across evaluated drugs, and home based DBS achieves high yield and adherence with patient preference around three quarters; DBS is a reliable and feasible option for decentralised TDM but needs careful design and evaluation before use.

    Reliability and feasibility of home-based dried blood spot in therapeutic drug monitoring: a systematic review and meta-analysisXiaoyong et al., European journal of clinical pharmacology (paywalled)

    • blood
    • dried
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • tdm
  47. 2023

    The study found that minimally invasive self-sampling at home was acceptable to most families, with saliva and hand sampling well tolerated across all ages and nasal sampling mainly accepted by adults and children over five. This supports the use of decentralised, patient-centric microsampling for long-term community surveillance of microbiota.

    Assessing the use of minimally invasive self-sampling at home for long-term monitoring of the microbiota within UK familiesNikolaou et al., Scientific reports

    • saliva
    • self-collection
    • acceptability
    • pediatric
    • microbiome
  48. 2023

    University branding increased trust and confidence in results, plain packaging promoted discretion, and colour‑coded bags with matching instructions reduced confusion; participants recommended instructional videos, tailored test options, real‑time introductions and personalised reminders to maximise return rates.

    Lessons Learned From the Implementation of a Pilot Study on Self-collected Specimen Return by Sexual Minority Men (Project Caboodle!): Qualitative ExplorationSallabank et al., JMIR formative research

    • blood
    • urine
    • capillary
    • self-collection
    • acceptability
    • sti
  49. 2023

    First-void urine tested on the GeneXpert platform detected high-risk HPV DNA with 84.8 per cent sensitivity and 92.3 per cent specificity compared with clinician-collected cervical samples, with substantial agreement (kappa 0.77) and high patient acceptability among 100 HIV-positive women in Zambia, suggesting that decentralised urine self-sampling with an EDTA preservative could widen cervical cancer screening coverage where invasive methods deter uptake.

    Utilizing first void urine for high-risk HPV testing for cervical cancer screening in HIV-positive women in Katete, ZambiaKaoma et al., BMC women's health

    • urine
    • first-void
    • validation
    • acceptability
    • hpv
  50. 2023

    Healthcare professionals in underserved French regions viewed home-based HPV self-sampling as a viable solution to low screening coverage, trusting vaginal sampling while accepting urine as an alternative for women with conditions such as vaginismus. They identified kit design flaws, instruction complexity, and patient anatomical knowledge gaps as implementation barriers requiring attention in decentralised screening programmes.

    Acceptability to Healthcare Professionals of Home-Based HPV Self-Sampling for Cervical Screening: A French Qualitative Study Conducted in an Area with Low Access to Health ServicesLe Goff et al., Cancers

    • urine
    • self-collection
    • acceptability
    • hpv
    • sti
  51. 2023

    Most young women found self-collected vaginal swabs easy and acceptable for STI testing, with 60.9% preferring them to urine samples when both were offered. The method was feasible in a community-based Zimbabwean setting, with high rates of understanding, privacy, and sense of control, suggesting it could expand access to STI screening.

    Acceptability of self-collected vaginal swabs for sexually transmitted infection testing among youth in a community-based setting in ZimbabweRochford et al., International journal of STD & AIDS

    • urine
    • self-collection
    • acceptability
    • sti
  52. 2023

    A qualitative study found that an online PrEP pathway incorporating postal self-sampling for HIV and STIs was highly acceptable to users and clinicians, offering convenience and service capacity benefits, though blood self-sampling was a barrier for some participants. The model suits established PrEP users with adequate digital literacy and requires integration with in-clinic support.

    Delivering HIV prevention medication online: Findings from a qualitative study exploring the acceptability of an online HIV pre-exposure prophylaxis (PrEP) care pathway among service users and healthcare professionalsKincaid et al., Digital health

    • blood
    • self-collection
    • acceptability
    • sti
  53. 2023

    The TASSO-M20 device for self-collected capillary blood demonstrated strong agreement with liquid whole blood for phosphatidylethanol (PEth) measurement (r²=0.988) and proved feasible and acceptable during virtual alcohol monitoring, causing less discomfort than finger stick methods. In a single participant tracked over time, PEth levels from the device aligned with urinary ethyl glucuronide and self-reported alcohol consumption.

    Validation of the quantification of phosphatidylethanol 16:0/18:1 concentrations in TASSO-M20 devicesJett et al., Alcohol, clinical & experimental research (paywalled)

    • blood
    • dried
    • capillary
    • dbs
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  54. 2023

    The study found that the Premom and Easy@Home urine-based luteinizing hormone testing systems provided estimates of peak fertility that were highly correlated with the Clearblue Fertility Monitor, suggesting they are accurate tools for ovulation detection and easy to use at home.

    A Comparison of Two Hormonal Fertility Monitoring Systems for Ovulation Detection: A Pilot StudyMu & Fehring, Medicina

    • urine
    • self-collection
    • acceptability
    • fertility
    • hormones
  55. 2023

    Self collected dried blood spots gave equivalent results to venous blood for lipids, HbA1c and C reactive protein, enabling similar classification of cardiovascular risk; self collection had lower response than nurse collection but similar demographic participation.

    A randomised study of nurse collected venous blood and self-collected dried blood spots for the assessment of cardiovascular risk factors in the Understanding Society Innovation PanelKumari et al., Scientific reports

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
    • biomarkers
  56. 2023

    This review surveys published LC-MS/MS methods that use dried blood microsampling for therapeutic drug monitoring of immunosuppressants in transplantation, chemotherapy and autoimmune disease, finding that volumetric dried blood samples can replace conventional venous draws for home sampling and improve patient quality of life. The authors discuss pre-analytical considerations, clinical applicability, cost-effectiveness, harmonisation gaps and patient perception, concluding that obstacles to routine clinical implementation remain despite growing methodological maturity.

    Dried blood microsampling-assisted therapeutic drug monitoring of immunosuppressants: An overviewDeprez & Stove, Journal of chromatography. A (paywalled)

    • blood
    • dried
    • dbs
    • volumetric
    • validation
    • acceptability
    • tdm
    • immunosuppressants
    • economics
  57. 2023

    Sexual minority men found finger-stick blood and rectal swabs more challenging to self-collect than other specimens. Barriers to returning samples included low confidence in self-collection and concerns about transit delays, while motivators were status confirmation and limited clinic access; real-time video support could improve uptake in future decentralised testing programmes.

    Perceptions and Experiences of Returning Self-collected Specimens for HIV, Bacterial STI and Potential PrEP Adherence Testing among Sexual Minority Men in the United StatesSharma et al., AIDS and behavior

    • blood
    • urine
    • self-collection
    • acceptability
    • serology
    • sti
  58. 2023

    The CandyCollect lollipop-inspired device achieved 100% concordance with commercial oral swabs and spit tubes for detecting salivary bacteria in 14 healthy adults who self-collected samples at home. Among 26 participants surveyed, the device was ranked highest for user preference, and it showed a one-year shelf life at room temperature, indicating potential for decentralised diagnostics and telemedicine applications.

    At-Home Saliva Sampling in Healthy Adults Using CandyCollect, a Lollipop-Inspired DeviceTu et al., Analytical chemistry (paywalled)

    • saliva
    • self-collection
    • validation
    • acceptability
  59. 2023

    Sexual health service providers in Ontario found self-sampling and virtual models for STBBI testing highly acceptable during COVID-19, viewing them as more convenient, accessible and safer than clinic-based testing while filling critical service gaps caused by pandemic resource reallocation. This real-world experience demonstrates the feasibility of decentralised, patient-centric STBBI testing and supports sustaining these models as essential healthcare.

    Disruptions of sexually transmitted and blood borne infections testing services during the COVID-19 pandemic: accounts of service providers in Ontario, CanadaRyu et al., BMC health services research

    • self-collection
    • acceptability
    • sti
  60. 2023

    In north-western Tanzania, self-collected cervical-vaginal swabs and urine were used for PCR detection of Female Genital Schistosomiasis; self-sampling was highly acceptable and detected more cases than operator-collected swabs, supporting its use in decentralised screening programmes.

    Assessing the prevalence of Female Genital Schistosomiasis and comparing the acceptability and performance of health worker-collected and self-collected cervical-vaginal swabs using PCR testing among women in North-Western Tanzania: The ShWAB studyUrsini et al., PLoS neglected tropical diseases

    • urine
    • self-collection
    • acceptability
  61. 2023

    In healthy adults, capillary blood collected with the Onflow device yielded similar chemistry results to venous blood and was rated more acceptable with lower pain than venepuncture, with high willingness to reuse and positive phlebotomist usability.

    Painless Capillary Blood Collection: A Rapid Evaluation of the Onflow DeviceNoble et al., Diagnostics

    • blood
    • liquid
    • capillary
    • venous-agreement
    • acceptability
  62. 2022

    A combined patient-preference and cost analysis of an at-home blood sampling device in chronic care, covering both what patients choose and what the shift costs the system.

    The societal impact of implementing an at-home blood sampling device for chronic care patients: patient preferences and cost impactLingervelder et al., BMC Health Services Research

    • economics
    • acceptability
    • self-collection
    • blood
  63. 2022

    A single VAMS run quantified two immunosuppressants plus creatinine with minimal haematocrit effect: combined drug-and-organ-function monitoring from one dried tip.

    A VAMS UPLC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Mycophenolic Acid and Creatinine in Whole Blood of Renal Transplant RecipientsWang et al., Pharmaceutics

    • vams
    • venous-agreement
    • acceptability
    • blood
    • tdm
    • haematocrit
    • dried
    • immunosuppressants
    • validation
  64. 2022

    Patients self-collected upper-arm capillary blood with press-activated devices including TAP II; autoantibody and CRP results agreed with venous at r≥0.98, were rated less painful, and 98.6% got enough blood within two attempts.

    Remote self-collection of upper-arm capillary blood for autoantibody analysis in immune-mediated rheumatic diseasesZarbl et al., RMD Open

    • venous-agreement
    • acceptability
    • blood
    • self-collection
    • capillary
    • liquid
    • yourbio
    • biomarkers
  65. 2022

    Capillary self-sampling gave CRP and autoantibody values nearly identical to venous, ICC 0.97–0.998, was less painful, and the upper-arm route drew far higher acceptance and willingness to sample at home.

    Accuracy and tolerability of capillary self-sampling for inflammation and autoantibodies in rheumatoid arthritis: a randomized controlled trialKnitza et al., Arthritis Research & Therapy

    • blood
    • liquid
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
  66. 2022

    The TAP device showed near perfect agreement with venous sampling for anti-Müllerian hormone measurements, with higher accuracy and lower pain compared to ADx card. This validates TAP as a reliable option for patient-led fertility hormone testing at home.

    Evaluation of at-home serum anti-Müllerian hormone testing: a head-to-head comparison studySilliman et al., Reproductive biology and endocrinology : RB&E

    • blood
    • capillary
    • yourbio
    • venous-agreement
    • acceptability
    • fertility
    • hormones
  67. 2022

    Among 446 STI clinic attendees in British Columbia, 73% were willing to self-collect urine samples outside clinics, 67% throat swabs and 65% anogenital swabs. Willingness was higher in those aged 35–54 years and lower among heterosexual compared with gay and lesbian participants, suggesting decentralised self-collection is acceptable and could extend STI screening beyond clinical settings.

    Attitudes and Preferences Regarding Non-Clinic-Based Self-Collection for Sexually Transmitted Infection Testing Among Clinic Attendees in British Columbia, CanadaGottschlich et al., Sexually transmitted diseases (paywalled)

    • urine
    • self-collection
    • acceptability
    • sti
  68. 2022

    Urine self-collection was acceptable to participants, but high-risk HPV mRNA detection in urine was less sensitive for high-grade cervical lesions than self- or provider-collected cervical samples. This suggests that while urine sampling may improve participation in decentralised screening programmes, it could miss more disease.

    High-Risk Human Papillomavirus Messenger RNA Testing Using Urine, Cervicovaginal Self-Collected and Provider-Collected Cervical Samples Among Women in Mombasa, KenyaGrabert et al., Sexually transmitted diseases (paywalled)

    • urine
    • self-collection
    • acceptability
    • hpv
    • sti
  69. 2022

    Pooled RT-qPCR of self-collected saliva from 824 asymptomatic employees identified two SARS-CoV-2 positives; one positive was detectable only by an amplification trend without a Ct value. A survey of 471 participants revealed that most would accept regular screening only if free or low-cost, supporting pooled saliva testing as a rapid, efficient, and inexpensive method for frequent large-scale decentralised screening.

    SARS-CoV-2 RT-qPCR testing of pooled saliva samples: A case study of 824 asymptomatic individuals and a questionnaire survey in JapanOba et al., PloS one

    • saliva
    • self-collection
    • acceptability
    • serology
  70. 2022

    Self‑collected nasal/oral swabs and saliva showed 77–87 per cent agreement with healthcare worker collection for SARS‑CoV‑2 detection by RT‑PCR, rising to 89 per cent for swabs when viral load was high. This demonstrates that self‑sampling can reliably support early COVID‑19 diagnosis in decentralised settings, reducing burden on healthcare workers.

    Diagnostic Performance, Stability, and Usability of Self-Collected Combo Swabs and Saliva for Coronavirus Disease 2019 Diagnosis: A Case-Control StudyChoi et al., Infection & chemotherapy

    • saliva
    • self-collection
    • acceptability
    • serology
  71. 2022

    Patients ranked pregnancy chance as the key facilitator for home-based LH urine testing in frozen embryo transfer cycles, while fear of missing ovulation was their main barrier. Healthcare providers agreed on pregnancy rates but cited laboratory capacity as their primary constraint, highlighting that decentralised fertility monitoring must address both patient confidence and system logistics to succeed.

    Facilitators and barriers for home-based monitoring to time frozen embryo transfers in IVF among women and healthcare providersZaat et al., Human reproduction open

    • urine
    • acceptability
    • fertility
    • hormones
  72. 2022

    Thirty-eight patients with rheumatic diseases showed high engagement with twice-daily smartphone symptom reporting (95% completion) and remote dried blood spot collection (84% returned samples, all viable for C-reactive protein analysis). Although symptoms varied considerably, clinically meaningful CRP changes were rare, confirming the feasibility of integrating microsampling with patient-generated health data in decentralised rheumatology research.

    Remote sampling of biomarkers of inflammation with linked patient generated health data in patients with rheumatic and musculoskeletal diseases: an Ecological Momentary Assessment feasibility studyDruce et al., BMC musculoskeletal disorders

    • blood
    • dried
    • dbs
    • self-collection
    • acceptability
    • biomarkers
    • rpm
    • digital-biomarker
    • multimodal
  73. 2022

    Capillary blood self-testing using the Hem-Col device demonstrated excellent correlation (r=0.992) and perfect agreement (kappa=1) with venous blood for anti-SARS-CoV-2 antibodies. Feasibility was markedly lower in participants aged 65 or more, who successfully collected the recommended volume in 62.5% of cases versus 86.2% in younger adults, suggesting older people need additional support such as telephone guidance or assistance from family for home-based sampling to be reliable.

    Feasibility of home-based ELISA capillary blood self-testing for anti-SARS-CoV-2 antibodiesBaggio et al., Practical laboratory medicine

    • blood
    • liquid
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
    • serology
  74. 2022

    Non-invasive self-sampling of anal colorectal mucus following defecation provides a patient-acceptable alternative to traditional stool collection for diagnosing colorectal cancer and inflammatory bowel disease. This emerging approach allows reliable measurement of diagnostic biomarkers to improve screening compliance.

    Emerging role of colorectal mucus in gastroenterology diagnosticsNooredinvand & Poullis, World journal of gastroenterology

    • self-collection
    • acceptability
    • colorectal
    • biomarkers
  75. 2022

    Among 1,082 participants, self-collection of saliva and anterior nasal swabs for SARS-CoV-2 testing was highly feasible with near-universal specimen submission, and at least 79% rated the process favourably for ease and comfort. With no clear preference between saliva and nasal swabs, the study supports both as viable options for decentralised infectious disease screening.

    Specimen self-collection for SARS-CoV-2 testing: Patient performance and preferences-Atlanta, Georgia, August-October 2020O'Laughlin et al., PloS one

    • saliva
    • self-collection
    • acceptability
    • serology
  76. 2022

    Teleconsent was perceived as more convenient than in-person consent with similar security and satisfaction, and achieved faster recruitment and fewer dropouts, supporting its use in decentralised trials.

    Participant comprehension and perspectives regarding the convenience, security, and satisfaction with teleconsent compared to in-person consent: A parallel-group pilot study among Danish citizensNyholm Gaarskjær et al., Contemporary clinical trials communications

    • acceptability
    • dct
  77. 2022

    In a rural Ecuadorian community, both urine and vaginal self-sampling for HPV testing were rated as more comfortable, more private, less painful and less difficult than clinician sampling. Vaginal self-sampling was the overall preferred method, suggesting that community training could increase uptake of decentralised cervical cancer screening.

    Evaluation of Urine and Vaginal Self-Sampling versus Clinician-Based Sampling for Cervical Cancer Screening: A Field Comparison of the Acceptability of Three Sampling Tests in a Rural Community of Cuenca, EcuadorVega Crespo et al., Healthcare

    • urine
    • self-collection
    • acceptability
    • hpv
    • sti
  78. 2022

    A national survey of 1,505 US adults found that 34% prioritised testing comfort, preferring saliva over nasal swab, while 20% avoided COVID-19 testing entirely. Offering at-home saliva tests with monetary incentives increased willingness to test among those who initially avoided testing or sought convenience, suggesting that patient-centric design can improve uptake of decentralised diagnostic programmes.

    Preferences Toward COVID-19 Diagnostic Testing Features: Results From a National Cross-Sectional SurveyKatare et al., American journal of health promotion : AJHP (paywalled)

    • saliva
    • self-collection
    • acceptability
  79. 2022

    Salivary glucocorticoid concentrations were comparable across Salivette Cortisol, passive drool and SalivaBio collection methods, and remained stable for 72 hours at room temperature and 4 degrees Celsius with no significant degradation after repeated freeze-thaw cycles. In children under six years, the SaliPac pacifier swab was well tolerated and collected sufficient saliva for steroid analysis in under four minutes.

    Salivary Steroid Collection in Children Under Conditions Replicating Home SamplingTonge et al., The Journal of clinical endocrinology and metabolism (paywalled)

    • saliva
    • liquid
    • self-collection
    • validation
    • acceptability
    • pediatric
    • hormones
    • cortisol
  80. 2022

    At a rural Ugandan HIV clinic, most women preferred nurse-led cervical screening to urine HPV self-sampling, yet self-collection proved feasible and detected high HPV prevalence, indicating that decentralised screening programmes must address acceptability through patient-centric education.

    The preference of women living with HIV for the HPV self-sampling of urine at a rural HIV clinic in UgandaNyabigambo et al., Southern African journal of infectious diseases

    • urine
    • self-collection
    • acceptability
    • hpv
    • sti
  81. 2022

    Urine testing for high-risk HPV achieved 86.2% sensitivity for detecting high-grade cervical lesions, slightly below the 94.8% sensitivity of cervical samples, while patient satisfaction was significantly higher with self-collected urine. High agreement for HPV 16/18 genotypes between the two methods supports urine as a viable alternative for decentralised cervical screening.

    A comparison of high-risk human papillomavirus DNA detection between urine and cervical sample testing in women with abnormal Pap smearsPunyashthira et al., The journal of obstetrics and gynaecology research (paywalled)

    • urine
    • self-collection
    • acceptability
    • hpv
    • sti
  82. 2022

    Self-collected dried blood spots enabled a mail-based SARS-CoV-2 serology survey among university affiliates, demonstrating practical feasibility but highlighting challenges in remote recruitment, supply chain constraints, potential sample bias and policy barriers to returning results. Key lessons include the need for clear participant instructions, robust logistics, household data linkage and on-call clinical support to ensure successful decentralised diagnostics.

    Optimizing the implementation of a participant-collected, mail-based SARS-CoV-2 serological survey in university-affiliated populations: lessons learned and practical guidanceCramer et al., BMC public health

    • blood
    • dried
    • dbs
    • self-collection
    • acceptability
    • serology
  83. 2022

    Self-collection of extragenital swabs identified Chlamydia or gonorrhoea in 7.3 per cent of people with HIV, all missed by urine testing alone. Sixty-three per cent of these infections were asymptomatic, self- and provider-collected samples yielded equivalent error rates, and participant satisfaction was high, demonstrating that decentralised, patient-led STI screening is both accurate and acceptable.

    Automated Sexual History and Self-Collection of Extragenital Chlamydia and Gonorrhea Improve Detection of Bacterial Sexually Transmitted Infections in People with HIVChapman et al., AIDS patient care and STDs (paywalled)

    • urine
    • self-collection
    • acceptability
    • sti
  84. 2022

    In a small substudy of psoriasis patients, lateral flow testing for adalimumab agreed very well with ELISA (r=0.95, R2=0.89) and capillary VAMS from finger prick correlated strongly with serum (r=0.87), while patients found home microsampling acceptable, indicating promise for decentralised TDM of biologics and warranting larger validation.

    Promising Tools to Facilitate the Implementation of TDM of Biologics in Clinical PracticeSoenen et al., Journal of clinical medicine

    • blood
    • dried
    • capillary
    • vams
    • self-collection
    • venous-agreement
    • acceptability
    • tdm
    • biologics
  85. 2022

    Dried blood spot testing achieved high acceptability among Métis community members in a culturally tailored pilot. Participants valued the ease of self-collection, the reduction of logistical barriers and stigma through event-based delivery, and the provision of Métis-specific services, suggesting that community-centred microsampling can expand HIV and sexually transmitted infection screening in decentralised diagnostics.

    Assessing the acceptability of dried blood spot testing for HIV and STBBI among Métis people in a community driven pilot project in Alberta, CanadaLandy et al., BMC health services research

    • blood
    • dried
    • dbs
    • self-collection
    • acceptability
    • serology
    • sti
  86. 2022

    Saliva shows promise as a patient-friendly alternative to nasopharyngeal swabs for COVID-19 diagnosis, particularly for decentralised testing, though variability in collection and processing methods affects sensitivity. Standardising protocols could improve reliability and support wider use in decentralised diagnostics.

    Saliva as an alternative specimen to nasopharyngeal swabs for COVID-19 diagnosis: ReviewMcPhillips & MacSharry, Access microbiology

    • saliva
    • self-collection
    • validation
    • acceptability
    • serology
  87. 2022

    Three-quarters of dementia care dyads completed eight weeks of in-home saliva collection for cortisol and DHEA-S, with patients and caregivers producing equally valid samples. This demonstrates that self-administered saliva collection is feasible even among people with cognitive impairment, supporting decentralised stress biomarker monitoring in this population.

    The Feasibility and Acceptability of In-Home Saliva Collection for Stress in Persons With Dementia and Their Family CaregiversEmami et al., Biological research for nursing (paywalled)

    • saliva
    • self-collection
    • acceptability
    • hormones
    • cortisol
  88. 2022

    In a pilot study of 100 adults, 70 per cent collected an adequate capillary blood sample using the Tasso-SST device, and among those with an adequate sample results showed high concordance with routine phlebotomy for SARS-CoV-2 antibody testing, supporting the use of this self-collection system in decentralised diagnostics.

    Comparison of a Blood Self-Collection System with Routine Phlebotomy for SARS-CoV-2 Antibody TestingWixted et al., Diagnostics

    • blood
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
    • serology
  89. 2022

    Women reported that urine collection was more acceptable than cervicovaginal self sampling, and most found the instructions clear, supporting the use of home based urine self collection to improve participation in cervical screening.

    Experiences and preferences towards collecting a urine and cervicovaginal self-sample among women attending a colposcopy clinicSchaafsma et al., Preventive medicine reports

    • urine
    • self-collection
    • acceptability
  90. 2022

    Higher engagement in regular HIV and STI testing was associated with incident STIs and health seeking behaviours, and participants rated self-sampling as convenient.

    Regular Testing of HIV and Sexually Transmitted Infections With Self-Collected Samples From Multiple Anatomic Sites to Monitor Sexual Health in Men Who Have Sex With Men: Longitudinal StudyWong et al., JMIR formative research

    • urine
    • self-collection
    • acceptability
    • sti
  91. 2022

    In a cohort of transgender women in São Paulo, self-collection of urine and other genital samples for STI screening was highly acceptable, with most participants preferring self-collection over provider collection for reasons of privacy and comfort; this supports the feasibility of decentralised, patient-centric sampling for STI diagnosis.

    Acceptability of self-sampling for etiological diagnosis of mucosal sexually transmitted infections (STIs) among transgender women in a longitudinal cohort study in São Paulo, BrazilMcCartney et al., The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases

    • urine
    • self-collection
    • acceptability
    • sti
  92. 2022

    In a Ugandan cohort, 96% of participants successfully collected at least 16 of 24 requested at-home dried blood spots, with strong correlation (R=0.93) between parasite RNA detected in self-collected spots and venous blood. The method was well tolerated, indicating self-collected DBS can reliably support decentralised malaria surveillance in endemic settings.

    Feasibility of community at-home dried blood spot collection combined with pooled reverse transcription PCR as a viable and convenient method for malaria epidemiology studiesHergott et al., Malaria journal

    • blood
    • dried
    • dbs
    • self-collection
    • venous-agreement
    • acceptability
    • pediatric
    • serology
  93. 2022

    Capillary blood self-sampling achieved 98.3% agreement with venous samples for SARS-CoV-2 IgG antibodies and 100% for IgA among 60 participants, demonstrating accuracy for vaccine monitoring. Saliva self-collection proved feasible with excellent usability, offering a patient-centric alternative for decentralised immunogenicity assessment.

    Self-collection of capillary blood and saliva to determine COVID-19 vaccine immunogenicity in patients with immune-mediated inflammatory diseases and health professionalsSchmetzer et al., Frontiers in public health

    • blood
    • saliva
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
    • serology
  94. 2022

    Among 92 patients on HIV pre-exposure prophylaxis, 79.3 per cent returned home-collected kits comprising dried blood spots, urine, and oropharyngeal swabs. Nearly 87.7 per cent were extremely to moderately satisfied with avoiding clinic visits, and mean turnaround fell from 17 to 5 days, showing self-collection is a feasible, patient-centric model for decentralised sexual health and SARS-CoV-2 screening.

    Feasibility and Acceptability of Home-Collected Samples for Human Immunodeficiency Virus Preexposure Prophylaxis and Severe Acute Respiratory Syndrome Coronavirus 2 Laboratory Tests in San Francisco Primary Care ClinicsSaberi et al., Open forum infectious diseases

    • blood
    • urine
    • dried
    • dbs
    • self-collection
    • acceptability
    • serology
    • sti
  95. 2022

    Capillary blood collected at home with the MiniCollect device showed good agreement with venous sampling for HbA1c analysis, supporting remote self-collection as a convenient alternative that maintains clinical performance and patient care during the COVID-19 pandemic.

    Remote capillary blood collection for HbA<sub>1c</sub> measurement during the COVID-19 pandemic: A laboratory and patient perspectiveGroenendijk et al., Diabetic medicine : a journal of the British Diabetic Association (paywalled)

    • blood
    • liquid
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • acceptability
  96. 2022

    Self-collected urine HPV testing in 195 transpeople showed 19.0% overall HPV positivity, with 79.0% preferring urine tests to provider-collected screening, indicating high acceptability and potential to reach an under-screened group.

    HPV screening in the urine of transpeople - A prevalence studyPils et al., EClinicalMedicine

    • urine
    • self-collection
    • acceptability
    • hpv
    • sti
  97. 2022

    Patients with systemic rheumatic diseases found at-home capillary blood self-sampling easy to use, and both patients and clinicians identified benefits such as time and cost savings, increased independence, and reduced COVID-19 infection risk. The approach could complement rheumatology telehealth services, though limited sample volume and usability challenges for those with functional restrictions are important considerations for implementation.

    At-home blood self-sampling in rheumatology: a qualitative study with patients and health care professionalsMuehlensiepen et al., BMC health services research

    • blood
    • capillary
    • self-collection
    • acceptability
  98. 2022

    Most patients with motor neuron disease expressed a positive attitude towards remote monitoring and participating in decentralised clinical trials from home, with a majority finding the use of multiple digital devices acceptable for tracking respiratory function and muscle strength.

    Patient perspectives on digital healthcare technology in care and clinical trials for motor neuron disease: an international surveyHelleman et al., Journal of neurology

    • acceptability
    • dct
    • rpm
  99. 2022

    The Tasso OnDemand device was well accepted by participants, with nearly all finding it easy to use and feeling confident they could self-sample at home, and paired self-collected and clinician-collected specimens showed high agreement for HIV, syphilis and creatinine tests. While most users collected enough serum for two monitoring tests, only a third produced sufficient volume for three tests, suggesting a larger-volume device may be preferable for full guideline-recommended PrEP monitoring.

    Feasibility of a novel self-collection method for blood samples and its acceptability for future home-based PrEP monitoringCannon et al., BMC infectious diseases

    • blood
    • liquid
    • capillary
    • self-collection
    • venous-agreement
    • acceptability
    • serology
    • sti
  100. 2022

    Generic saliva self-collection devices enabled safe unsupervised home sampling that yielded adequate quantity and quality for SARS-CoV-2 nucleocapsid gene detection, with stability maintained after temperature cycling to simulate summer and winter shipping. This supports a patient-centric decentralised approach to infectious-disease screening without requiring healthcare professionals.

    Evaluation of saliva self-collection devices for SARS-CoV-2 diagnosticsAllicock et al., BMC infectious diseases

    • saliva
    • self-collection
    • validation
    • acceptability
    • serology

Read from the corpus on .