2019 · Journal of clinical and translational science · open access
Application of volumetric absorptive microsampling (VAMS) to measure multidimensional anti-influenza IgG antibodies by the mPlex-Flu assay
Wang et al.
The finding, in our words
VAMS capillary blood showed strong agreement with venous serum for measuring anti-influenza antibodies and remained stable for three weeks at room temperature. When volunteers performed finger-stick sampling at home, their results were highly consistent with on-site collection by study personnel.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
The study found very strong correlation between venous blood collection and capillary VAMS using Mitra devices for detecting SARS-CoV-2 spike antibodies, with samples remaining stable at room temperature for several months. This enables reliable at-home, patient-centric serological testing for large-scale community surveillance and vaccine studies.
Mayer et al., Journal of immunological methods (paywalled) · source ↗
Capillary blood collected by fingerstick with the Mitra volumetric absorptive microsampling device showed near identical sensitivity and specificity for SARS-CoV-2 antibodies compared with venous serum when analysed with the Roche Elecsys assay. This validation enables decentralised, patient-centric serology testing for remote or at-home use and large-scale community seroprevalence studies.
Garcia-Beltran et al., Archives of pathology & laboratory medicine (paywalled) · source ↗
Capillary samples collected using dried blood spots and Mitra microsamplers showed strong agreement with venous plasma for quantifying IgG antibodies against most vaccine-preventable diseases. Sensitivity was high for the majority of pathogens, though the study noted that antibody stability declined at room temperature over time, favouring cold storage for longer durations.
Ombati et al., Scientific reports (paywalled) · source ↗
In participants 11 months after SARS-CoV-2 infection, the nano-immunoassay achieved 98.33% sensitivity and 97.62% specificity on venous serum. When combined with dried capillary microsampling, sensitivity was 95.05% with Mitra, 61.11% with repurposed glucose strips and 83.16% with HemaXis (91.49% after automated extraction), with no loss of specificity, supporting home-based sampling for serology.
Clinical validation for tacrolimus and mycophenolic acid monitoring showed that while volumetric absorptive microsampling met analytical criteria after concentration correction, conventional dried blood spots achieved superior adherence to strict clinical criteria, sample quality, and cost efficiency without significant haematocrit bias.
Paniagua-González et al., Journal of pharmaceutical and biomedical analysis (paywalled) · source ↗