Remote Fingerstick Blood Collection for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Antibody Testing
Garcia-Beltran et al.
The finding, in our words
Capillary blood collected by fingerstick with the Mitra volumetric absorptive microsampling device showed near identical sensitivity and specificity for SARS-CoV-2 antibodies compared with venous serum when analysed with the Roche Elecsys assay. This validation enables decentralised, patient-centric serology testing for remote or at-home use and large-scale community seroprevalence studies.