Skip to content
OpenSampling

2025 · Therapeutic drug monitoring · paywalled

Implementation of Volumetric Finger-Prick Self-Sampling for Therapeutic Drug Monitoring of Immunosuppressants After Kidney Transplantation: Lessons Learned From the Practice

Vethe et al.

The finding, in our words

The paper summarises that volumetric finger-prick self-sampling is suitable for monitoring immunosuppressants and biomarkers after kidney transplantation, but successful implementation requires careful design of the entire workflow, including patient training and method validation. This matters because it provides a real-world framework for moving critical monitoring from the clinic to the patient's home.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug MonitoringHuhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗

    • vams
    • volumetric
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  2. 2025

    A validated offline SPE-LC-MS/MS method using the Mitra microsampling device successfully quantified tacrolimus, cyclosporine A, tryptophan, kynurenine, and creatinine simultaneously. The method met EMA and FDA criteria, showing agreement between capillary and venous sampling, which could facilitate decentralised therapeutic drug monitoring and transplant follow-up through patient self-collection.

    An Offline SPE-LC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Cyclosporine A, Kynurenine, Tryptophan, and Creatinine Using Volumetric Absorptive Microsampling Device MitraNierychlewski et al., Therapeutic drug monitoring · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • tdm
    • dried
    • capillary
    • immunosuppressants
    • validation
    • biomarkers
  3. 2024

    Head-to-head clinical validation of two VAMS devices for tacrolimus and mycophenolic acid, with roughly 86–88% of samples within ±20% of venous.

    Clinical validation of two volumetric absorptive microsampling devices to support home-based therapeutic drug monitoring of immunosuppressionLeino et al., British Journal of Clinical Pharmacology (paywalled) · source ↗

    • vams
    • venous-agreement
    • acceptability
    • neoteryx-mitra
    • blood
    • tdm
    • self-collection
    • dried
    • immunosuppressants
    • validation
  4. 2023

    A study of 37 kidney transplant recipients found Capitainer and Mitra microsampling feasible for decentralised monitoring. Capitainer showed consistent sampling success, 92%-96%, and higher analytical accuracy than Mitra, 52%-88% success. Proportions within ±15% of venous reference for creatinine and haemoglobin were 92%-100% and 93%-100% for Capitainer, versus 79%-96% and 67%-92% for Mitra, despite small cohorts.

    Clinical performance of volumetric finger-prick sampling for the monitoring of tacrolimus, creatinine and haemoglobin in kidney transplant recipientsVethe et al., British journal of clinical pharmacology (paywalled) · source ↗

    • blood
    • capillary
    • qdbs
    • volumetric
    • neoteryx-mitra
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
  5. 2022

    Clinical validation for tacrolimus and mycophenolic acid monitoring showed that while volumetric absorptive microsampling met analytical criteria after concentration correction, conventional dried blood spots achieved superior adherence to strict clinical criteria, sample quality, and cost efficiency without significant haematocrit bias.

    Comparison of conventional dried blood spots and volumetric absorptive microsampling for tacrolimus and mycophenolic acid determinationPaniagua-González et al., Journal of pharmaceutical and biomedical analysis (paywalled) · source ↗

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • neoteryx-mitra
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • economics
    • haematocrit