Skip to content
OpenSampling

2025 · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · paywalled

Imatinib and norimatinib therapeutic monitoring using dried blood spots: Analytical and clinical validation, and performance comparison of volumetric collection devices

Orleni et al.

The finding, in our words

LC-MS/MS measurement of imatinib and its active metabolite from volumetric dried blood spots collected via HemaXis DB10 and Capitainer B demonstrated analytical precision across hematocrits from 22% to 55% alongside 43-day ambient stability. Clinical evaluation across 52 paired samples showed high agreement with plasma concentrations, verifying both devices as reliable options for decentralised therapeutic drug monitoring.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    Clinical Validation of Venetoclax Volumetric Microsampling in Leukemia, with Whole-Blood-to-Plasma Conversion and Self-Microsampling Feasibility

    In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.

    Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗

    • vams
    • volumetric
    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • capillary
    • validation
  2. 2025

    Patient centric blood sampling and analysis for diagnostics and laboratory medicine

    A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.

    Spooner et al., Bioanalysis · source ↗

    • vams
    • dct
    • volumetric
    • venous-agreement
    • acceptability
    • doping
    • blood
    • economics
    • dbs
    • tdm
    • standards
    • self-collection
    • haematocrit
    • dried
    • steroids
    • serology
    • oncology
    • toxicology
    • capillary
    • pediatric
    • hormones
    • liquid
    • immunosuppressants
    • validation
    • biomarkers
  3. 2023

    Blood microsampling technologies: Innovations and applications in 2022

    Microsampling reduces sample volume, invasiveness, logistics and biohazard risk while improving stability and enabling at-home self-sampling, yet clinical adoption remains slow and requires standardisation and harmonisation to realise its patient-centric and decentralised potential.

    Thangavelu et al., Analytical science advances · source ↗

    • vams
    • volumetric
    • biologics
    • doping
    • blood
    • dbs
    • metabolome
    • tdm
    • standards
    • haematocrit
    • dried
    • serology
    • antimicrobials
    • oncology
    • toxicology
    • capillary
    • liquid
    • immunosuppressants
    • validation
    • biomarkers
  4. 2023

    LC-MS/MS Method for the Quantification of PARP Inhibitors Olaparib, Rucaparib and Niraparib in Human Plasma and Dried Blood Spot: Development, Validation and Clinical Validation for Therapeutic Drug Monitoring

    The authors developed and validated an LC-MS/MS method for measuring three PARP inhibitors in both plasma and dried blood spots. They found strong agreement between the two matrices for olaparib and niraparib, suggesting DBS could support therapeutic drug monitoring for these oncology drugs in decentralised settings.

    Canil et al., Pharmaceutics · source ↗

    • blood
    • dried
    • dbs
    • volumetric
    • validation
    • venous-agreement
    • tdm
    • oncology
    • haematocrit
  5. 2022

    Leveraging patient-centric sampling for clinical drug development and decentralized clinical trials: Promise to reality

    An IQ Consortium position paper from sponsor scientists positioning patient-centric sampling as the enabling technology for decentralised trials, and stating that a bridging study against conventional sampling “has quickly been established as a regulatory expectation”.

    Maass et al., Clinical and Translational Science · source ↗

    • vams
    • dct
    • volumetric
    • venous-agreement
    • biologics
    • acceptability
    • blood
    • dbs
    • qdbs
    • tdm
    • standards
    • self-collection
    • haematocrit
    • dried
    • capillary
    • pediatric
    • liquid
    • validation
    • biomarkers