Clinical Validation of a Capillary Blood Home-Based Self-Sampling Technique for Monitoring of Infliximab, Vedolizumab, and C-Reactive Protein Concentrations in Patients With Inflammatory Bowel Disease
Otten et al.
The finding, in our words
Capillary finger prick sampling at home showed close agreement with venous sampling for measuring infliximab, vedolizumab and CRP, with no systematic bias and high patient tolerability and practicality, supporting decentralised monitoring of biologic therapy in IBD.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
Capillary blood collection using liquid and dried microsampling devices yielded pharmacokinetic profiles comparable to venous sampling for two monoclonal antibodies and a small molecule, whereas haematocrit correction was necessary for dried formats and bridging was ineffective for hydroxychloroquine. The findings demonstrate the bioanalytical feasibility and patient acceptability of remote microsampling tools for pharmacokinetic evaluations in decentralised clinical trials.
Volumetric microsampling can enable patient-centred therapeutic drug monitoring with high patient preference and acceptable method validation for many drugs, but conversion from capillary to plasma and agreement with venous sampling varies by analyte and requires careful validation.
In a cohort of 62 participants evaluating home self-collection with the TassoPlus device, 38 returned samples, with 29% excluded due to insufficient plasma volume below 200 ΔL. Although viral load measurements in adequate samples correlated well with conventional testing (r = 0.800), the high failure rate and missed detection in low-volume viremic samples indicate that further technical refinements are necessary before clinical adoption.
Home DBS sampling gave testosterone results that agreed well with venous blood in men on intramuscular testosterone undecanoate, but showed falsely high values in those using topical gel, likely from skin contamination. Patients preferred home collection for its convenience, suggesting DBS is viable for decentralised monitoring of injectable testosterone if patients are taught proper technique.
This study established conversion methods for estimating plasma concentrations from whole blood VAMS samples for seven out of ten oral anticancer drugs, finding good agreement between capillary and venous samples. Patients reported a positive experience with home sampling using this microsampling technique.