Application of volumetric absorptive microsampling for robust, high-throughput mass spectrometric quantification of circulating protein biomarkers

van den Broek et al.

The finding, in our words

Volumetric absorptive microsampling with the Mitra device enables accurate, reproducible quantification of circulating protein biomarkers from a 10 µL finger-prick blood sample, with extraction recovery of 100–111% across haematocrit levels and stable peptide responses after 22 weeks at -80°C. The automated mass spectrometry workflow reproducibly detected 1661 peptides from 423 proteins, correlating with plasma measurements, which supports remote, personalised disease monitoring.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug Monitoring

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.

    Huhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗

    • vams
    • volumetric
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  2. 2026

    Rapid, robust LC-MS/MS quantification of cefazolin in whole blood microsamples, plasma, and plasma ultrafiltrate: Analytical method validation and preliminary clinical application in pediatric population

    The study developed and validated a rapid LC-MS/MS method for quantifying cefazolin in capillary whole blood collected via VAMS, plasma, and plasma ultrafiltrate, showing robust performance across matrices and successful application in a pediatric pilot cohort for therapeutic drug monitoring.

    Kocur et al., Clinica chimica acta; international journal of clinical chemistry (paywalled) · source ↗

    • vams
    • neoteryx-mitra
    • blood
    • tdm
    • haematocrit
    • dried
    • antimicrobials
    • capillary
    • pediatric
    • validation
  3. 2026

    Multi-Matrix LC-MS/MS Validation of Methotrexate Polyglutamates: Comparison of VAMS, DBS, and Conventional Blood Sampling in Rheumatoid Arthritis

    In matched clinical samples from rheumatoid arthritis, VAMS and DBS showed strong agreement for methotrexate polyglutamates (slopes 0.95-1.07; bias within -4.21% to 0.36%; SRCC ≥ 0.969), with up to 100% of total MTXPG results within ±20% limits; capillary microsampling agreed closely with whole blood but differed from red blood cells, indicating matrix-specific differences that must be accounted for when interpreting against RBC-based reference values.

    Kocur et al., International journal of molecular sciences · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
    • validation
  4. 2025

    A validated method for capillary phosphatidylethanol 16:0/18:1 quantification with two different 10-µl volumetric absorptive microsample devices in the same setup

    This study validated a method for measuring the alcohol biomarker phosphatidylethanol using two volumetric absorptive microsampling devices, finding that the Mitra device met all validation criteria and agreed with venous sampling. The Capitainer device was deemed suitable but showed reduced accuracy at higher concentrations, with a small proportional negative bias compared to venous results.

    Andreassen et al., Journal of analytical toxicology (paywalled) · source ↗

    • vams
    • volumetric
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • dried
    • toxicology
    • capillary
    • validation
    • biomarkers
  5. 2025

    Quantitation of BCAA and BCKA in plasma and patient-centric dried blood microsamples in a clinical setting

    A comparison of three patient-centric dried blood microsampling devices, paper DBS, Mitra and Tasso-M20, found strong to excellent correlation with traditional venous plasma for measuring branched-chain amino acids and ketoacids. Participants reported high acceptability and expressed a strong willingness to use these devices for decentralised self-collection.

    Tierney et al., Bioanalysis · source ↗

    • vams
    • venous-agreement
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • metabolome
    • dried
    • capillary
    • validation
    • biomarkers