Skip to content
OpenSampling

2024 · Brain, behavior, and immunity · paywalled

Remote dried blood spot collection for inflammatory markers in older adults is feasible, reliable, and valid

Reed et al.

The finding, in our words

Older adults achieved 98% adherence when self-collecting dried blood spots at home for inflammatory markers, with 97% of samples yielding valid results. Test-retest reliability was good (ICCs 0.70–0.76) and correlation with venous blood was strong (r=0.60–0.99), demonstrating that remote capillary sampling is a feasible and valid method for decentralised assessment of inflammation in older adults.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2025

    Patient centric blood sampling and analysis for diagnostics and laboratory medicine

    A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.

    Spooner et al., Bioanalysis · source ↗

    • vams
    • dct
    • volumetric
    • venous-agreement
    • acceptability
    • doping
    • blood
    • economics
    • dbs
    • tdm
    • standards
    • self-collection
    • haematocrit
    • dried
    • steroids
    • serology
    • oncology
    • toxicology
    • capillary
    • pediatric
    • hormones
    • liquid
    • immunosuppressants
    • validation
    • biomarkers
  2. 2022

    Leveraging patient-centric sampling for clinical drug development and decentralized clinical trials: Promise to reality

    An IQ Consortium position paper from sponsor scientists positioning patient-centric sampling as the enabling technology for decentralised trials, and stating that a bridging study against conventional sampling “has quickly been established as a regulatory expectation”.

    Maass et al., Clinical and Translational Science · source ↗

    • vams
    • dct
    • volumetric
    • venous-agreement
    • biologics
    • acceptability
    • blood
    • dbs
    • qdbs
    • tdm
    • standards
    • self-collection
    • haematocrit
    • dried
    • capillary
    • pediatric
    • liquid
    • validation
    • biomarkers
  3. 2021

    Digitally Enabled, Patient-Centric Clinical Trials: Shifting the Drug Development Paradigm

    Merck describes a digitally enabled, patient-centric trial initiative that combines outpatient PK/PD sampling with digital biomarkers and smart dosing technologies to improve exposure-response understanding and reduce patient burden, while acknowledging adoption challenges.

    Dockendorf et al., Clinical and translational science · source ↗

    • vams
    • dct
    • volumetric
    • actigraphy
    • wearable
    • venous-agreement
    • acceptability
    • multimodal
    • blood
    • rpm
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
    • digital-biomarker
    • validation
    • biomarkers
  4. 2026

    Clinical validation of a DBS-based LC-MS/MS method for 25-hydroxyvitamin D: from lab sampling to home sampling

    Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.

    Heughebaert et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗

    • venous-agreement
    • blood
    • dbs
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
    • biomarkers
  5. 2026

    Dried Blood Spot for CXCL-10 and Tacrolimus: Integrated Non-Invasive Monitoring to Guide Personalized Treatment in Adult Kidney Transplant Recipients

    This study validated a dried blood spot method for tacrolimus monitoring and demonstrated agreement with venous whole blood measurements in kidney transplant recipients. It also found that dried blood spot analysis of the biomarker CXCL-10 was elevated in patients experiencing rejection or infection, supporting its use for decentralised monitoring.

    Millán et al., Pharmaceuticals · source ↗

    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
    • immunosuppressants
    • validation
    • biomarkers