The finding, in our words

In 33 patients, dried blood spots showed high correlation with venipuncture for adalimumab, Pearson ≥0.96, whereas home sampling showed moderate correlation with predicted concentrations, Pearson 0.51.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2022

    Leveraging patient-centric sampling for clinical drug development and decentralized clinical trials: Promise to reality

    An IQ Consortium position paper from sponsor scientists positioning patient-centric sampling as the enabling technology for decentralised trials, and stating that a bridging study against conventional sampling “has quickly been established as a regulatory expectation”.

    Maass et al., Clinical and Translational Science · source ↗

    • vams
    • dct
    • volumetric
    • venous-agreement
    • biologics
    • acceptability
    • blood
    • dbs
    • qdbs
    • tdm
    • standards
    • self-collection
    • haematocrit
    • dried
    • capillary
    • pediatric
    • liquid
    • validation
    • biomarkers
  2. 2019

    Dried blood samples can support monitoring of infliximab concentrations in patients with inflammatory bowel disease: A clinical validation

    A clinical validation showing dried blood samples can support infliximab concentration monitoring in inflammatory bowel disease.

    Berends et al., British Journal of Clinical Pharmacology · source ↗

    • vams
    • venous-agreement
    • biologics
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  3. 2026

    Clinical Validation of Venetoclax Volumetric Microsampling in Leukemia, with Whole-Blood-to-Plasma Conversion and Self-Microsampling Feasibility

    In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.

    Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗

    • vams
    • volumetric
    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • capillary
    • validation
  4. 2026

    Dried Blood Spot for CXCL-10 and Tacrolimus: Integrated Non-Invasive Monitoring to Guide Personalized Treatment in Adult Kidney Transplant Recipients

    This study validated a dried blood spot method for tacrolimus monitoring and demonstrated agreement with venous whole blood measurements in kidney transplant recipients. It also found that dried blood spot analysis of the biomarker CXCL-10 was elevated in patients experiencing rejection or infection, supporting its use for decentralised monitoring.

    Millán et al., Pharmaceuticals · source ↗

    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
    • immunosuppressants
    • validation
    • biomarkers
  5. 2026

    Patient-centric capillary dried blood spot sampling for tacrolimus and creatinine monitoring in clinical practice

    The study found that quantitative dried blood spot sampling provided high clinical agreement for tacrolimus and creatinine monitoring, with patients rating the self-collection devices as user-friendly. These results support the feasibility of decentralised therapeutic drug monitoring for immunosuppressants.

    De Baets et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗

    • blood
    • dried
    • capillary
    • dbs
    • qdbs
    • self-collection
    • venous-agreement
    • acceptability
    • tdm
    • immunosuppressants