Liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring of immunosuppressants and creatinine from a single dried blood spot using the Capitainer® qDBS device

Deprez et al.

The finding, in our words

Deprez et al. validated LC‑MS/MS methods for four immunosuppressants and creatinine from a single 10 μL quantitative dried blood spot. With biases under 10 % and CVs below 8 %, the approach enables accurate patient‑centric therapeutic drug monitoring from capillary blood at home, mitigating the haematocrit effect through volumetric collection.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2025

    Microsampling, particularly VAMS and quantitative DBS, can enable patient-centric therapeutic drug monitoring of immunosuppressants after transplantation, allowing home self-sampling and long-term monitoring when patients live far from transplant centres. These volumetric dried formats have largely overcome the haematocrit effect and sample heterogeneity that limit conventional dried blood spots.

    Microsampling techniques and patient-centric therapeutic drug monitoring of immunosuppressantsKocur & Pawiński, Bioanalysis (paywalled) · source ↗

    • vams
    • volumetric
    • venous-agreement
    • blood
    • qdbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
  2. 2026

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug MonitoringHuhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗

    • vams
    • volumetric
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  3. 2026

    Volumetric microsampling can enable patient-centred therapeutic drug monitoring with high patient preference and acceptable method validation for many drugs, but conversion from capillary to plasma and agreement with venous sampling varies by analyte and requires careful validation.

    Volumetric Microsampling for Patient-Centric Therapeutic Drug Monitoring in Clinical Pharmacology: A Scoping ReviewTummala et al., Journal of clinical pharmacology (paywalled) · source ↗

    • volumetric
    • venous-agreement
    • acceptability
    • blood
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  4. 2025

    A validated LC-MS/MS method for everolimus using Mitra and Capitainer devices found excellent agreement between capillary microsamples and venous whole blood in 33 adult transplant recipients. The results showed high accuracy and negligible haematocrit effects, supporting the use of microsampling for decentralised therapeutic drug monitoring.

    Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative StudyKocur et al., Molecules · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • qdbs
    • tdm
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
    • validation
  5. 2023

    A study of 37 kidney transplant recipients found Capitainer and Mitra microsampling feasible for decentralised monitoring. Capitainer showed consistent sampling success, 92%-96%, and higher analytical accuracy than Mitra, 52%-88% success. Proportions within ±15% of venous reference for creatinine and haemoglobin were 92%-100% and 93%-100% for Capitainer, versus 79%-96% and 67%-92% for Mitra, despite small cohorts.

    Clinical performance of volumetric finger-prick sampling for the monitoring of tacrolimus, creatinine and haemoglobin in kidney transplant recipientsVethe et al., British journal of clinical pharmacology (paywalled) · source ↗

    • blood
    • capillary
    • qdbs
    • volumetric
    • neoteryx-mitra
    • self-collection
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants