Hepcidin determination in dried blood by microfluidic LC-MS/MS: comparison of DBS and volumetric absorptive microsampling for matrix effect and recovery
Houbart et al.
The finding, in our words
Combining volumetric absorptive microsampling with phospholipid removal plates reduces matrix effects and delivers high sensitivity for dried blood hepcidin quantification. This method establishes a reliable microsampling protocol to quantify this peptide hormone while mitigating haematocrit bias.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
This study compared four dried blood spot devices for glucocorticoid detection, finding that the Mitra VAMS device offered the best combination of analytical recovery and user usability, whilst the HemaXis DB10 showed the least bias compared to whole blood.
This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.
A liquid chromatography-tandem mass spectrometry method was successfully validated for measuring androstenedione, 17α-hydroxyprogesterone, and 11-ketotestosterone in dried blood samples collected via volumetric absorptive microsampling. The dried samples remained stable at room temperature for up to a week and after postal transit, and plasma concentrations could be reliably estimated from the microsamples when adjusting for haematocrit.
The study validated an LC-MS/MS method for eight antiepileptic drugs and two metabolites in dried blood spot and VAMS formats, with satisfactory analytical performance and stability, and was the first to include the oxcarbazepine metabolite DHCB. In 80 paired patient samples, microsampling concentrations showed promising correlation with plasma, supporting decentralised therapeutic drug monitoring of antiepileptic treatment.
The study compared five microsampling devices, including Mitra tips and Tasso-M20, for detecting 27 steroid esters in dried blood by LC-MS/MS, and found that methanol extraction with Girard's reagent P or T provided the best screening sensitivity with detection limits of 0.05 to 1.0 ng/mL, while methoxyamine derivatization was recommended for confirming boldenone and certain testosterone esters. The Tasso-M20 device produced chromatographic interference with methanol extraction that was only partially resolved by using mixed solvents, at the cost of lower recoveries.