Comparability of different analytical workflows for steroid esters detection in doping control field

Mazzarino et al.

The finding, in our words

The study compared five microsampling devices, including Mitra tips and Tasso-M20, for detecting 27 steroid esters in dried blood by LC-MS/MS, and found that methanol extraction with Girard's reagent P or T provided the best screening sensitivity with detection limits of 0.05 to 1.0 ng/mL, while methoxyamine derivatization was recommended for confirming boldenone and certain testosterone esters. The Tasso-M20 device produced chromatographic interference with methanol extraction that was only partially resolved by using mixed solvents, at the cost of lower recoveries.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2025

    This study compared four dried blood spot devices for glucocorticoid detection, finding that the Mitra VAMS device offered the best combination of analytical recovery and user usability, whilst the HemaXis DB10 showed the least bias compared to whole blood.

    Analytical and usability comparison of microsampling dried blood spot devices for glucocorticoid detection in sports using ultra-high-performance liquid chromatography-tandem mass spectrometryChen et al., Analytica chimica acta (paywalled) · source ↗

    • vams
    • acceptability
    • neoteryx-mitra
    • doping
    • blood
    • dbs
    • haematocrit
    • dried
    • toxicology
    • hormones
    • validation
  2. 2026

    The analysis indicates that dried blood spots and volumetric absorptive microsampling enable minimally invasive monitoring of prohibited substances, with volumetric absorptive microsampling offering improved quantitative reliability over traditional dried spots.

    Liquid Chromatographic Methods for Microsampling in Sports Drug Monitoring: Progress in DBS and VAMSZhang, Biomedical chromatography : BMC (paywalled) · source ↗

    • vams
    • doping
    • blood
    • dbs
    • dried
    • steroids
    • toxicology
    • hormones
    • validation
    • biomarkers
  3. 2025

    The authors found that a single microdose of recombinant EPO was detectable up to 72 hours using ITP and CP methods, though the Tasso microsampling device showed lower sensitivity than Mitra and Capitainer. Additionally, isotope ratio mass spectrometry successfully detected testosterone micro-dosing in all analysed samples, supported by serum testosterone levels.

    Detection of a Single Microdose of Testosterone and Recombinant EPO in Healthy VolunteersHeiland et al., Drug testing and analysis · source ↗

    • neoteryx-mitra
    • doping
    • blood
    • dbs
    • dried
    • steroids
    • toxicology
    • capillary
    • hormones
    • urine
    • validation
  4. 2017

    The study developed and validated an LC-MS/MS method for THC, its metabolites and synthetic cannabinoids in both dried blood spots and VAMS, showing that VAMS eliminates the haematocrit effect that limits DBS accuracy, thereby providing a reliable tool for toxicological and anti-doping analysis in decentralised settings.

    Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoidsProtti et al., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (paywalled) · source ↗

    • vams
    • neoteryx-mitra
    • doping
    • blood
    • dbs
    • haematocrit
    • dried
    • toxicology
    • validation
  5. 2026

    A validated two-step LC-MS/MS protocol can identify 91 prohibited doping agents from a single dried blood spot collected on either cellulose cards or volumetric absorptive microsampling devices. This demonstrates robust multi-analyte screening from capillary blood, supporting decentralised anti-doping programmes where venous sampling is impractical.

    Dried Blood Spots for Doping Purpose-Two-Step Protocol for Analysis of Non-Threshold Substances and Anabolic Steroid Esters From One Spot/PebbleStojanovic et al., Biomedical chromatography : BMC (paywalled) · source ↗

    • blood
    • dried
    • capillary
    • vams
    • dbs
    • validation
    • doping
    • toxicology