2024 · Analytical and bioanalytical chemistry · paywalled
A miniaturized sample preparation method for routine elemental determination in whole blood using volumetric absorptive micro-sampling by ICP-QQQ
Schmidt et al.
The finding, in our words
The study validated a method for determining 15 trace elements in whole blood collected via VAMS, showing high precision and accuracy with agreement to a liquid sampling method. This supports the use of VAMS for decentralised trace element analysis in clinical and research settings.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
Researchers successfully validated an analytical method for measuring creatinine across plasma and volumetric absorptive microsampling devices, demonstrating strong correlation between conventional plasma and dried microsamples. This provides a reliable, patient-centric approach for monitoring kidney function remotely during transplant follow-up.
Untargeted metabolomic profiles from three blood microsampling devices aligned more closely with whole blood than with plasma, and all devices distinguished sex based on amino acids, lipids, and acylcarnitines. This validates that device choice can be tailored to the metabolites of interest for decentralised human biomonitoring.
A comparison of three patient-centric dried blood microsampling devices, paper DBS, Mitra and Tasso-M20, found strong to excellent correlation with traditional venous plasma for measuring branched-chain amino acids and ketoacids. Participants reported high acceptability and expressed a strong willingness to use these devices for decentralised self-collection.
A validated offline SPE-LC-MS/MS method using the Mitra microsampling device successfully quantified tacrolimus, cyclosporine A, tryptophan, kynurenine, and creatinine simultaneously. The method met EMA and FDA criteria, showing agreement between capillary and venous sampling, which could facilitate decentralised therapeutic drug monitoring and transplant follow-up through patient self-collection.
Capillary blood collection using volumetric absorptive microsampling demonstrated equivalent quantification of principal colonic polyphenol metabolites compared with matched venous plasma across a six-hour period following barley biscuit consumption. The technique successfully captured the pharmacokinetic profiles over 48 hours, confirming VAMS as a reliable alternative to venepuncture for dietary biomarker monitoring.