Volumetric absorptive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs

Velghe & Stove

The finding, in our words

The study validated a method for measuring four anti-epileptic drugs and one metabolite using volumetric absorptive microsampling, showing high precision and accuracy with minimal haematocrit bias. The compounds remained stable in VAMS samples for at least one month at various temperatures, supporting the use of this microsampling technique for therapeutic drug monitoring.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    Evaluation of hematocrit-adjusted conversion strategies for mycophenolic acid and tacrolimus monitoring using volumetric absorptive microsampling in lung and renal transplant recipients

    In lung and renal transplant recipients, VAMS sampling with LC-MS/MS quantification of mycophenolic acid and tacrolimus showed good linearity and accuracy, and with a haematocrit-adjusted conversion formula achieved clinical agreement in most samples; tacrolimus did not require haematocrit correction. The approach is virtually painless and enables richer sampling for more accurate drug exposure estimates, supporting decentralised therapeutic drug monitoring.

    Juan et al., Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit
  2. 2026

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug Monitoring

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.

    Huhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗

    • vams
    • volumetric
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  3. 2026

    Development and application of an LC-MS/MS method for 8 antiepileptic drugs and 2 metabolites using microsampling techniques (DBS and VAMS)

    The study validated an LC-MS/MS method for eight antiepileptic drugs and two metabolites in dried blood spot and VAMS formats, with satisfactory analytical performance and stability, and was the first to include the oxcarbazepine metabolite DHCB. In 80 paired patient samples, microsampling concentrations showed promising correlation with plasma, supporting decentralised therapeutic drug monitoring of antiepileptic treatment.

    Cobo-Golpe et al., Journal of analytical toxicology · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • haematocrit
    • dried
    • pediatric
    • validation
  4. 2026

    Rapid, robust LC-MS/MS quantification of cefazolin in whole blood microsamples, plasma, and plasma ultrafiltrate: Analytical method validation and preliminary clinical application in pediatric population

    The study developed and validated a rapid LC-MS/MS method for quantifying cefazolin in capillary whole blood collected via VAMS, plasma, and plasma ultrafiltrate, showing robust performance across matrices and successful application in a pediatric pilot cohort for therapeutic drug monitoring.

    Kocur et al., Clinica chimica acta; international journal of clinical chemistry (paywalled) · source ↗

    • vams
    • neoteryx-mitra
    • blood
    • tdm
    • haematocrit
    • dried
    • antimicrobials
    • capillary
    • pediatric
    • validation
  5. 2026

    Volumetric absorptive microsampling and conductive vial electromembrane extraction for the analysis of pharmaceuticals in whole blood

    This study demonstrates that a commercial conductive vial electromembrane extraction device can reliably isolate basic pharmaceuticals from whole blood collected on volumetric absorptive microsampling tips, showing superior reproducibility and reduced matrix effects compared to conventional treatment.

    Reguli et al., Talanta (paywalled) · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • tdm