2018 · Clinica chimica acta; international journal of clinical chemistry · paywalled
Study of measurement of the alcohol biomarker phosphatidylethanol (PEth) in dried blood spot (DBS) samples and application of a volumetric DBS device
Beck et al.
The finding, in our words
Dried blood spot sampling showed close agreement with venous whole blood for phosphatidylethanol measurement, with both Whatman 903 cards and a volumetric DBS device yielding comparable results. Haematocrit correlated positively with PEth concentration, and quantification imprecision was acceptable at clinically relevant levels.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.
An IQ Consortium position paper from sponsor scientists positioning patient-centric sampling as the enabling technology for decentralised trials, and stating that a bridging study against conventional sampling “has quickly been established as a regulatory expectation”.
Maass et al., Clinical and Translational Science · source ↗
In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.
Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗
Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.
Heughebaert et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗
This study found that measuring thyroid-stimulating hormone via dried blood spots and a volumetric device showed high agreement with serum results, with classification accuracy exceeding 96 per cent. The volumetric approach demonstrated improved reproducibility and stability, supporting its use for decentralised thyroid function monitoring.
Bornikowska et al., Practical laboratory medicine · source ↗