Skip to content
OpenSampling

2026 · Drug and alcohol dependence reports · open access

Reference values for the alcohol biomarker phosphatidylethanol (PEth) in the Belgian population: Insights from a nationwide microsampling study

Vandenbroucke et al.

The finding, in our words

PEth reference values for Belgium were derived from VAMS microsampling of 487 participants in a national survey, showing distinct biomarker distributions between the general population and higher‑alcohol‑consumption subgroups. This validates capillary blood collection as a practical method for decentralised alcohol monitoring and forensic assessment.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    Stressing the limits of capillary blood in anti-doping analysis: perspectives on alkylamine-like stimulants and carbonic anhydrase II inhibitors in result management

    Capillary blood collected by volumetric absorptive microsampling gave a shorter detection window than urine for a stimulant, helping to distinguish recent from earlier use, and more reliable detection of long-acting diuretics that bind red cells. This shows microsampling can improve interpretation in drug-monitoring programmes where urinary data alone may be ambiguous.

    da Costa Nunes et al., Frontiers in sports and active living · source ↗

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • doping
    • toxicology
  2. 2026

    Thiamine status in Belgian adults assessed by volumetric absorptive microsampling: a nation-wide cross-sectional survey

    In a nationwide survey of 1047 Belgian adults, at-home VAMS achieved a 63% participation-to-analysis completion rate with 16% of samples excluded due to insufficient quality. While dietary intake suggested adequate thiamine consumption, 11% of participants had blood thiamine diphosphate concentrations below the reference threshold, showing the utility of remote microsampling for identifying true nutritional status.

    Heughebaert et al., The American journal of clinical nutrition (paywalled) · source ↗

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • self-collection
    • biomarkers
  3. 2025

    A validated method for capillary phosphatidylethanol 16:0/18:1 quantification with two different 10-µl volumetric absorptive microsample devices in the same setup

    This study validated a method for measuring the alcohol biomarker phosphatidylethanol using two volumetric absorptive microsampling devices, finding that the Mitra device met all validation criteria and agreed with venous sampling. The Capitainer device was deemed suitable but showed reduced accuracy at higher concentrations, with a small proportional negative bias compared to venous results.

    Andreassen et al., Journal of analytical toxicology (paywalled) · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • dried
    • toxicology
    • capillary
    • validation
  4. 2025

    An Offline SPE-LC-MS/MS Method for Simultaneous Quantification of Tacrolimus, Cyclosporine A, Kynurenine, Tryptophan, and Creatinine Using Volumetric Absorptive Microsampling Device Mitra

    A validated offline SPE-LC-MS/MS method using the Mitra microsampling device successfully quantified tacrolimus, cyclosporine A, tryptophan, kynurenine, and creatinine simultaneously. The method met EMA and FDA criteria, showing agreement between capillary and venous sampling, which could facilitate decentralised therapeutic drug monitoring and transplant follow-up through patient self-collection.

    Nierychlewski et al., Therapeutic drug monitoring · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • tdm
    • dried
    • capillary
    • immunosuppressants
    • validation
    • biomarkers
  5. 2025

    Inflammation markers associated with symptoms and neighborhood deprivation in black adults with heart failure

    In 41 Black adults with heart failure, elevated xanthine oxidase activity from capillary blood collected with Mitra microsampling associated significantly with dyspnoea severity. This demonstrates that microsampling can capture clinically relevant inflammatory biomarkers linked to symptom burden in underserved populations, supporting its use in decentralised cardiovascular monitoring.

    Butts et al., Heart & lung : the journal of critical care (paywalled) · source ↗

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • biomarkers