2026 · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · paywalled
Matrix fidelity in microsampling: Plasma-first LC-MS/MS quantification of mycophenolic acid and MPAG
Kocur et al.
The finding, in our words
This study validated a method for monitoring mycophenolic acid in paediatric patients, demonstrating that quantitative dried plasma spots achieved close agreement with venous plasma. Quantitative dried blood spots showed significant haematocrit-related bias, making the plasma-based format more suitable for decentralised monitoring.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
A validated LC-MS/MS method for everolimus using Mitra and Capitainer devices found excellent agreement between capillary microsamples and venous whole blood in 33 adult transplant recipients. The results showed high accuracy and negligible haematocrit effects, supporting the use of microsampling for decentralised therapeutic drug monitoring.
In children with SLE, VAMS finger-prick capillary blood gave haematocrit-adjusted MPA and MPAG concentrations indistinguishable from plasma, and the AUC from VAMS derived plasma-equivalent concentrations matched plasma AUC with R2 0.97. This supports accurate pharmacokinetically guided dosing of MMF using only three timed capillary microsamples.
Zhao et al., The journal of applied laboratory medicine (paywalled) · source ↗
A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.
The study validated a VAMS-based LC-MS/MS method for measuring sirolimus levels, showing it was clinically equivalent to the standard whole blood method and suitable for therapeutic drug monitoring in paediatric transplant patients, supporting the use of decentralised microsampling for this purpose.
Kocur et al., Pharmacological reports : PR · source ↗
A study of 50 paediatric renal transplant recipients found that a validated VAMS LC-MS/MS method for tacrolimus showed high correlation with the reference method over 0.5–60 ng/mL, with minimal haematocrit effect.