Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients

Qu et al.

The finding, in our words

VAMS microsampling of capillary blood provided accurate measurement of hydroxychloroquine and metabolites in rheumatoid arthritis patients, with results agreeing with venous blood while overcoming dried blood spot limitations of haematocrit bias and inhomogeneity, and offered potential for home self-collection.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    Clinical Validation of Venetoclax Volumetric Microsampling in Leukemia, with Whole-Blood-to-Plasma Conversion and Self-Microsampling Feasibility

    In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.

    Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗

    • vams
    • volumetric
    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • capillary
    • validation
  2. 2026

    Multi-Matrix LC-MS/MS Validation of Methotrexate Polyglutamates: Comparison of VAMS, DBS, and Conventional Blood Sampling in Rheumatoid Arthritis

    In matched clinical samples from rheumatoid arthritis, VAMS and DBS showed strong agreement for methotrexate polyglutamates (slopes 0.95-1.07; bias within -4.21% to 0.36%; SRCC ≥ 0.969), with up to 100% of total MTXPG results within ±20% limits; capillary microsampling agreed closely with whole blood but differed from red blood cells, indicating matrix-specific differences that must be accounted for when interpreting against RBC-based reference values.

    Kocur et al., International journal of molecular sciences · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
    • validation
  3. 2025

    Patient centric blood sampling and analysis for diagnostics and laboratory medicine

    A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.

    Spooner et al., Bioanalysis · source ↗

    • vams
    • dct
    • volumetric
    • venous-agreement
    • acceptability
    • doping
    • blood
    • economics
    • dbs
    • tdm
    • standards
    • self-collection
    • haematocrit
    • dried
    • steroids
    • serology
    • oncology
    • toxicology
    • capillary
    • pediatric
    • hormones
    • liquid
    • immunosuppressants
    • validation
    • biomarkers
  4. 2025

    Blood self-sampling devices: innovation, interpretation and implementation in total lab automation

    The authors observe that self-sampling devices for capillary blood are gaining traction as a patient-preferred alternative to venous collection, with one centre reporting a 15 percent reduction in laboratory test volumes when local collection was offered. They argue that successful integration into total laboratory automation requires addressing cost, transport regulations and sample volume adequacy while ensuring robust device design and seamless workflow compatibility.

    Poland & Cobbaert, Clinical chemistry and laboratory medicine (paywalled) · source ↗

    • vams
    • venous-agreement
    • acceptability
    • blood
    • economics
    • dbs
    • qdbs
    • tdm
    • standards
    • self-collection
    • dried
    • serology
    • oncology
    • capillary
    • liquid
    • immunosuppressants
    • validation
  5. 2023

    VAMS and parallel-reaction-monitoring mass spectrometry for tacrolimus trough measurements at home in paediatric heart-transplant patients

    VAMS microsampling found no significant difference from venous blood for tacrolimus in paediatric patients; samples were stable for 14 days, with average difference between paired at-home samples of 0.12 ± 0.94 ng/mL.

    Zhao et al., J. Mass Spectrometry and Advances in the Clinical Lab · source ↗

    • vams
    • venous-agreement
    • acceptability
    • blood
    • dbs
    • tdm
    • self-collection
    • dried
    • capillary
    • pediatric
    • immunosuppressants
    • validation