A comprehensive approach for detection of biotin deficiency from dried blood spot samples using liquid chromatography-mass spectrometry
Raveendran et al.
The finding, in our words
The authors developed and fully validated a liquid chromatography-mass spectrometry method to measure biotin deficiency biomarkers from dried blood spot samples. They demonstrated correlation with plasma measurements and applied the method to establish population reference ranges in South India, supporting decentralised screening and monitoring of biotin deficiency.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.
An IQ Consortium position paper from sponsor scientists positioning patient-centric sampling as the enabling technology for decentralised trials, and stating that a bridging study against conventional sampling “has quickly been established as a regulatory expectation”.
Maass et al., Clinical and Translational Science · source ↗
Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.
Heughebaert et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗
Capillary finger-stick dried blood spots demonstrated strong analytical agreement with venous serum for prostate-specific antigen (R² = 0.987) and remained stable for 31 days across a wide temperature range. This less invasive microsampling approach enables at-home self-collection, supporting decentralised screening and tele-diagnostics for prostate cancer.
van Vugt et al., The journal of applied laboratory medicine (paywalled) · source ↗
The study validated an LC-MS/MS method for eight antiepileptic drugs and two metabolites in dried blood spot and VAMS formats, with satisfactory analytical performance and stability, and was the first to include the oxcarbazepine metabolite DHCB. In 80 paired patient samples, microsampling concentrations showed promising correlation with plasma, supporting decentralised therapeutic drug monitoring of antiepileptic treatment.
Cobo-Golpe et al., Journal of analytical toxicology · source ↗