Skip to content
OpenSampling

2019 · Analytical and bioanalytical chemistry · paywalled

Volumetric absorptive microsampling as an alternative sampling strategy for the determination of paracetamol in blood and cerebrospinal fluid

Delahaye et al.

The finding, in our words

The study developed and validated two LC-MS/MS methods for quantifying paracetamol in dried blood and dried cerebrospinal fluid using VAMS, showing acceptable precision and accuracy, limited haematocrit influence, and stability under various storage conditions, thus proving the utility of VAMS for CSF microsampling.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    In lung and renal transplant recipients, VAMS sampling with LC-MS/MS quantification of mycophenolic acid and tacrolimus showed good linearity and accuracy, and with a haematocrit-adjusted conversion formula achieved clinical agreement in most samples; tacrolimus did not require haematocrit correction. The approach is virtually painless and enables richer sampling for more accurate drug exposure estimates, supporting decentralised therapeutic drug monitoring.

    Evaluation of hematocrit-adjusted conversion strategies for mycophenolic acid and tacrolimus monitoring using volumetric absorptive microsampling in lung and renal transplant recipientsJuan et al., Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit
  2. 2026

    This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.

    A Review of Blood-Based Microsampling Devices for Patient-Centered Application in Therapeutic Drug MonitoringHuhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗

    • vams
    • volumetric
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
  3. 2026

    A liquid chromatography-tandem mass spectrometry method was successfully validated for measuring androstenedione, 17α-hydroxyprogesterone, and 11-ketotestosterone in dried blood samples collected via volumetric absorptive microsampling. The dried samples remained stable at room temperature for up to a week and after postal transit, and plasma concentrations could be reliably estimated from the microsamples when adjusting for haematocrit.

    Analytical validation of a dried blood microsampling method to measure androstenedione, 17α‑hydroxyprogesterone, and 11‑ketotestosterone for congenital adrenal hyperplasia monitoringDe Baets et al., Talanta (paywalled) · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • pediatric
    • hormones
    • haematocrit
  4. 2026

    The study validated an LC-MS/MS method for eight antiepileptic drugs and two metabolites in dried blood spot and VAMS formats, with satisfactory analytical performance and stability, and was the first to include the oxcarbazepine metabolite DHCB. In 80 paired patient samples, microsampling concentrations showed promising correlation with plasma, supporting decentralised therapeutic drug monitoring of antiepileptic treatment.

    Development and application of an LC-MS/MS method for 8 antiepileptic drugs and 2 metabolites using microsampling techniques (DBS and VAMS)Cobo-Golpe et al., Journal of analytical toxicology · source ↗

    • blood
    • dried
    • vams
    • dbs
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • haematocrit
  5. 2026

    The study developed and validated a rapid LC-MS/MS method for quantifying cefazolin in capillary whole blood collected via VAMS, plasma, and plasma ultrafiltrate, showing robust performance across matrices and successful application in a pediatric pilot cohort for therapeutic drug monitoring.

    Rapid, robust LC-MS/MS quantification of cefazolin in whole blood microsamples, plasma, and plasma ultrafiltrate: Analytical method validation and preliminary clinical application in pediatric populationKocur et al., Clinica chimica acta; international journal of clinical chemistry (paywalled) · source ↗

    • vams
    • neoteryx-mitra
    • blood
    • tdm
    • haematocrit
    • dried
    • antimicrobials
    • capillary
    • pediatric
    • validation