Skip to content
OpenSampling

2023 · Molecules · open access

New Trend in Toxicological Screening Using Volumetric Absorptive Microsampling (VAMS) and High-Resolution Mass Spectrometry (HR/MS) Combination

Houzé et al.

The finding, in our words

In whole blood spiked with 90 drugs, the VAMS method using the Neoteryx Mitra device confirmed 87 compounds with identification limits below 12.5 ng/mL for 82.2% of drugs and extraction yields of 80.6 to 108.7%. In 15 poisoned patients, 98% of plasma compounds were detected in VAMS with satisfactory concordance (R2 = 0.827), supporting its use for decentralised toxicology screening.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2025

    A validated method for capillary phosphatidylethanol 16:0/18:1 quantification with two different 10-µl volumetric absorptive microsample devices in the same setup

    This study validated a method for measuring the alcohol biomarker phosphatidylethanol using two volumetric absorptive microsampling devices, finding that the Mitra device met all validation criteria and agreed with venous sampling. The Capitainer device was deemed suitable but showed reduced accuracy at higher concentrations, with a small proportional negative bias compared to venous results.

    Andreassen et al., Journal of analytical toxicology (paywalled) · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • dried
    • toxicology
    • capillary
    • validation
  2. 2023

    Method development for the quantification of lead levels in whole blood sampled on Mitra<sup>®</sup> with VAMS<sup>®</sup> tips by inductively coupled plasma-MS/MS

    A VAMS method using Mitra devices for whole blood lead quantification showed no significant difference compared with the centre's routine method, supporting VAMS as a practical alternative for blood lead and other trace element analyses.

    Breton et al., Bioanalysis (paywalled) · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • toxicology
  3. 2022

    Mercury biomonitoring in German adults using volumetric absorptive microsampling

    Capillary VAMS combined with direct mercury analysis demonstrated strong correlation with venous blood mercury concentrations in adult volunteers, with acceptable accuracy and precision above 1.0 µg/l. Storage in pre-cleaned glass vials following two hours of desiccator drying maintained analyte stability for at least four weeks.

    Koutsimpani-Wagner et al., Environmental monitoring and assessment · source ↗

    • blood
    • dried
    • capillary
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • toxicology
  4. 2026

    Surrogate-based LC-MS/MS quantification of endogenous creatinine in plasma, plasma-equivalent dried spots (qDPS), and volumetric absorptive microsampling (VAMS): an ICH M10-compliant bridging study

    Researchers successfully validated an analytical method for measuring creatinine across plasma and volumetric absorptive microsampling devices, demonstrating strong correlation between conventional plasma and dried microsamples. This provides a reliable, patient-centric approach for monitoring kidney function remotely during transplant follow-up.

    Kocur et al., European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences (paywalled) · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dried
    • validation
    • biomarkers
  5. 2026

    Evaluation of hematocrit-adjusted conversion strategies for mycophenolic acid and tacrolimus monitoring using volumetric absorptive microsampling in lung and renal transplant recipients

    In lung and renal transplant recipients, VAMS sampling with LC-MS/MS quantification of mycophenolic acid and tacrolimus showed good linearity and accuracy, and with a haematocrit-adjusted conversion formula achieved clinical agreement in most samples; tacrolimus did not require haematocrit correction. The approach is virtually painless and enables richer sampling for more accurate drug exposure estimates, supporting decentralised therapeutic drug monitoring.

    Juan et al., Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit