Fluispotter, a novel automated and wearable device for accurate volume serial dried blood spot sampling
Adhikari et al.
The finding, in our words
The Fluispotter device automated serial dried blood spot collection with high accuracy and precision for cortisol quantification across a haematocrit range of 22–55% when validated against plasma. This supports its use for reliable, patient-centric microsampling of steroid hormones in decentralised diagnostics.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.
Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗
This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.
Huhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗
Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.
Heughebaert et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗
Capillary finger-stick dried blood spots demonstrated strong analytical agreement with venous serum for prostate-specific antigen (R² = 0.987) and remained stable for 31 days across a wide temperature range. This less invasive microsampling approach enables at-home self-collection, supporting decentralised screening and tele-diagnostics for prostate cancer.
van Vugt et al., The journal of applied laboratory medicine (paywalled) · source ↗
Finger-stick dried blood spots produce creatinine measurements that correlate strongly with venous plasma (R² = 0.97), with 91% sensitivity and 96% specificity for detecting reduced eGFR. Creatinine stays stable in dried spots for up to one month at refrigerated or frozen temperatures, supporting accurate home-based kidney function screening, patient follow-up, and medication management.
van Dam et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗