2020 · Biomedical chromatography : BMC · paywalled
Development and validation of volumetric absorptive microsampling coupled with UHPLC-MS/MS for the analysis of gamma-hydroxybutyric acid in human blood
Mohamed et al.
The finding, in our words
A VAMS method for measuring gamma-hydroxybutyric acid in blood was fully validated, showing linearity from 0.5 to 200 μg/ml and a lower limit of quantitation of 0.5 μg/ml. The method compared well with conventional plasma analysis in a patient receiving GHB therapy, suggesting microsampling could support decentralised therapeutic drug monitoring for this compound.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.