Comprehensive lipidomic profiling by plasma separation cards
Bishop & Fiehn
The finding, in our words
Plasma separation cards (PSC) provided quantitative lipidomic profiles from a single blood drop that correlated well with wet plasma and outperformed dried blood spots (DBS), though inter-lot variability was modestly higher (14.6% RSD). While 60% of lipids remained stable at room temperature for 28 days, stability limitations persist for non-clinical settings and comparability varies by lipid class.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
Volumetric absorptive microsampling showed better precision than dried blood spots and a metabolic profile closer to whole blood, with stable signalling lipids for 24 hours at room temperature but significant changes after one week unless stabilised, indicating feasibility for decentralised sampling with the need for storage strategies.
Thangavelu et al., Analytical and bioanalytical chemistry · source ↗
Untargeted metabolomic profiles from three blood microsampling devices aligned more closely with whole blood than with plasma, and all devices distinguished sex based on amino acids, lipids, and acylcarnitines. This validates that device choice can be tailored to the metabolites of interest for decentralised human biomonitoring.
Avella et al., Metabolomics : Official journal of the Metabolomic Society · source ↗
This study validated a method for measuring the alcohol biomarker phosphatidylethanol using two volumetric absorptive microsampling devices, finding that the Mitra device met all validation criteria and agreed with venous sampling. The Capitainer device was deemed suitable but showed reduced accuracy at higher concentrations, with a small proportional negative bias compared to venous results.
Andreassen et al., Journal of analytical toxicology (paywalled) · source ↗
A comparison of three patient-centric dried blood microsampling devices, paper DBS, Mitra and Tasso-M20, found strong to excellent correlation with traditional venous plasma for measuring branched-chain amino acids and ketoacids. Participants reported high acceptability and expressed a strong willingness to use these devices for decentralised self-collection.
A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.