Shipping Conditions May Impact the Reliability of At-Home Microsampling Devices
Villanueva Raisman et al.
The finding, in our words
DBS microsampling devices produced unreliable proteomic results when samples were shipped at high ambient temperatures typical of summer conditions. Ensuring sample stability during transport is therefore critical for trustworthy biomarker measurement in decentralised healthcare and population screening.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
Volumetric absorptive microsampling showed better precision than dried blood spots and a metabolic profile closer to whole blood, with stable signalling lipids for 24 hours at room temperature but significant changes after one week unless stabilised, indicating feasibility for decentralised sampling with the need for storage strategies.
Thangavelu et al., Analytical and bioanalytical chemistry · source ↗
This study validated a method for measuring the alcohol biomarker phosphatidylethanol using two volumetric absorptive microsampling devices, finding that the Mitra device met all validation criteria and agreed with venous sampling. The Capitainer device was deemed suitable but showed reduced accuracy at higher concentrations, with a small proportional negative bias compared to venous results.
Andreassen et al., Journal of analytical toxicology (paywalled) · source ↗
A 2025 review maps 28 microsampling devices, from dried spots and volumetric absorptive tips to upper-arm liquid capillary collectors, and names what a laboratory must control before their results are used: the haematocrit effect in non-volumetric dried samples, interstitial fluid from finger milking, volume, haemolysis and transport stability. Regulators on both sides of the Atlantic ask for the same two things, a device the patient can use safely and a sample fit for the test.
Volumetric dried blood spot microsampling enables retinol analysis with over 90% extraction efficiency from only 10 µL of blood, though α-tocopherol recovery ranges from 53 to 75% depending on filter paper. The method improves sample stability to 30 days at -80°C and reduces shipping volume more than a thousandfold, making micronutrient monitoring practical for decentralised settings.
In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.
Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗