2016 · PLoS neglected tropical diseases · open access
Pharmacokinetic Study of Praziquantel Enantiomers and Its Main Metabolite R-trans-4-OH-PZQ in Plasma, Blood and Dried Blood Spots in Opisthorchis viverrini-Infected Patients
Meister et al.
The finding, in our words
DBS sampling yielded drug concentrations that agreed with plasma at 79–94% for praziquantel enantiomers and 108–122% for its metabolite in nine opisthorchiasis patients. This validates DBS as a practical alternative to conventional venous sampling for therapeutic drug monitoring in resource-limited settings.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.
This study validated a dried blood spot method for tacrolimus monitoring and demonstrated agreement with venous whole blood measurements in kidney transplant recipients. It also found that dried blood spot analysis of the biomarker CXCL-10 was elevated in patients experiencing rejection or infection, supporting its use for decentralised monitoring.
Home DBS sampling gave testosterone results that agreed well with venous blood in men on intramuscular testosterone undecanoate, but showed falsely high values in those using topical gel, likely from skin contamination. Patients preferred home collection for its convenience, suggesting DBS is viable for decentralised monitoring of injectable testosterone if patients are taught proper technique.
The study validated an LC-MS/MS method for eight antiepileptic drugs and two metabolites in dried blood spot and VAMS formats, with satisfactory analytical performance and stability, and was the first to include the oxcarbazepine metabolite DHCB. In 80 paired patient samples, microsampling concentrations showed promising correlation with plasma, supporting decentralised therapeutic drug monitoring of antiepileptic treatment.
In matched clinical samples from rheumatoid arthritis, VAMS and DBS showed strong agreement for methotrexate polyglutamates (slopes 0.95-1.07; bias within -4.21% to 0.36%; SRCC ≥ 0.969), with up to 100% of total MTXPG results within ±20% limits; capillary microsampling agreed closely with whole blood but differed from red blood cells, indicating matrix-specific differences that must be accounted for when interpreting against RBC-based reference values.