Evaluation of the Mitra microsampling device for use with key urinary metabolites in patients with Alkaptonuria

Taylor et al.

The finding, in our words

Volumetric absorptive microsampling provided accurate and precise measurement of key urinary metabolites in alkaptonuria with good recovery and reproducibility, and dried samples compared favourably with liquid specimens, although variable analyte stability may present barriers to routine implementation.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    The authors developed and optimised a dual LC-MS workflow for non-targeted metabolomics from blood microsamples, comprising a 15-minute HILIC-MS method for polar metabolites and an RPLC-MS method for mid- to non-polar compounds. A 20% water/80% methanol extraction with rehydration offered a practical compromise that detected numerous metabolite features across amino acid, acylcarnitine and bile acid pathways, enabling decentralised metabolomic analysis.

    RPLC- and HILIC-based non-targeted metabolomics workflow for blood microsamplesCouacault & Witting, Metabolomics : Official journal of the Metabolomic Society · source ↗

    • vams
    • neoteryx-mitra
    • blood
    • dbs
    • metabolome
    • dried
    • validation
  2. 2026

    Untargeted metabolomic profiles from three blood microsampling devices aligned more closely with whole blood than with plasma, and all devices distinguished sex based on amino acids, lipids, and acylcarnitines. This validates that device choice can be tailored to the metabolites of interest for decentralised human biomonitoring.

    An LC-MS untargeted metabolomic comparison between three blood microsampling devices, whole blood, and plasmaAvella et al., Metabolomics : Official journal of the Metabolomic Society · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • metabolome
    • biomarkers
  3. 2025

    A comparison of three patient-centric dried blood microsampling devices, paper DBS, Mitra and Tasso-M20, found strong to excellent correlation with traditional venous plasma for measuring branched-chain amino acids and ketoacids. Participants reported high acceptability and expressed a strong willingness to use these devices for decentralised self-collection.

    Quantitation of BCAA and BCKA in plasma and patient-centric dried blood microsamples in a clinical settingTierney et al., Bioanalysis · source ↗

    • vams
    • venous-agreement
    • acceptability
    • neoteryx-mitra
    • blood
    • dbs
    • metabolome
    • dried
    • validation
    • biomarkers
  4. 2025

    In an untargeted metabolomics study, microsampling devices, particularly the Mitra and Capitainer, yielded metabolic profiles comparable or superior to plasma in feature number and intensity, and in the precision and stability of some metabolites. This supports their potential for large-scale, decentralised metabolic profiling, though the captured metabolite profile was application-dependent.

    LC-MS-Based Global Metabolic Profiles of Alternative Blood Specimens Collected by MicrosamplingThaitumu et al., Metabolites · source ↗

    • vams
    • neoteryx-mitra
    • blood
    • dbs
    • qdbs
    • metabolome
    • dried
    • validation
    • biomarkers
  5. 2025

    This study found that dried blood microsamples, particularly those collected with the Mitra device, provided metabolic profiles comparable or superior to conventional plasma, supporting their use as a viable alternative for untargeted metabolomics.

    Toward minimally invasive metabolomics: GC-MS metabolic fingerprints of dried blood microsamples in comparison to plasmaMarques de Sá E Silva et al., The Analyst (paywalled) · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • metabolome
    • dried
    • capillary
    • validation