Skip to content
OpenSampling

2023 · Molecules · open access

Analytical and Clinical Validation of Assays for VAMS of Drugs in Different Blood Matrices: A Literature Review

Nugraha et al.

The finding, in our words

A structured review: many VAMS assays are analytically validated and can substitute for venous sampling for well-characterised analytes, though clinical-validation depth varies.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    In lung and renal transplant recipients, VAMS sampling with LC-MS/MS quantification of mycophenolic acid and tacrolimus showed good linearity and accuracy, and with a haematocrit-adjusted conversion formula achieved clinical agreement in most samples; tacrolimus did not require haematocrit correction. The approach is virtually painless and enables richer sampling for more accurate drug exposure estimates, supporting decentralised therapeutic drug monitoring.

    Evaluation of hematocrit-adjusted conversion strategies for mycophenolic acid and tacrolimus monitoring using volumetric absorptive microsampling in lung and renal transplant recipientsJuan et al., Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit
  2. 2026

    In matched clinical samples from rheumatoid arthritis, VAMS and DBS showed strong agreement for methotrexate polyglutamates (slopes 0.95-1.07; bias within -4.21% to 0.36%; SRCC ≥ 0.969), with up to 100% of total MTXPG results within ±20% limits; capillary microsampling agreed closely with whole blood but differed from red blood cells, indicating matrix-specific differences that must be accounted for when interpreting against RBC-based reference values.

    Multi-Matrix LC-MS/MS Validation of Methotrexate Polyglutamates: Comparison of VAMS, DBS, and Conventional Blood Sampling in Rheumatoid ArthritisKocur et al., International journal of molecular sciences · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • dbs
    • tdm
    • dried
    • capillary
    • immunosuppressants
    • validation
  3. 2025

    A study of 12 kidney transplant recipients providing 69 paired samples found that a VAMS-based assay for mycophenolic acid and its metabolite had 90% to 106% accuracy. Converting microsampling results to plasma concentrations met agreement criteria, supporting decentralised monitoring, though the study was small and limited to a single centre.

    Development and Clinical Validation of a Volumetric Absorptive Capillary Microsampling Method for Quantification of Mycophenolic Acid and Mycophenolic Acid Glucuronide in Kidney Transplant RecipientsDrevland et al., Therapeutic drug monitoring (paywalled) · source ↗

    • vams
    • venous-agreement
    • blood
    • tdm
    • dried
    • capillary
    • immunosuppressants
    • validation
  4. 2025

    A validated LC-MS/MS method for everolimus using Mitra and Capitainer devices found excellent agreement between capillary microsamples and venous whole blood in 33 adult transplant recipients. The results showed high accuracy and negligible haematocrit effects, supporting the use of microsampling for decentralised therapeutic drug monitoring.

    Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative StudyKocur et al., Molecules · source ↗

    • vams
    • venous-agreement
    • neoteryx-mitra
    • blood
    • qdbs
    • tdm
    • haematocrit
    • dried
    • capillary
    • immunosuppressants
    • validation
  5. 2025

    In children with SLE, VAMS finger-prick capillary blood gave haematocrit-adjusted MPA and MPAG concentrations indistinguishable from plasma, and the AUC from VAMS derived plasma-equivalent concentrations matched plasma AUC with R2 0.97. This supports accurate pharmacokinetically guided dosing of MMF using only three timed capillary microsamples.

    Volumetric Absorptive Microsampling Combined with Mass Spectrometry to Support Pharmacokinetically-Guided Precision Dosing of Mycophenolate Mofetil in Pediatric Lupus Nephritis PatientsZhao et al., The journal of applied laboratory medicine (paywalled) · source ↗

    • vams
    • venous-agreement
    • blood
    • tdm
    • haematocrit
    • dried
    • capillary
    • pediatric
    • immunosuppressants
    • validation