Skip to content
OpenSampling

2021 · Journal of pharmaceutical and biomedical analysis · paywalled

A validated surrogate analyte LC-MS/MS assay for quantification of endogenous cortisol in human whole blood

Agrawal et al.

The finding, in our words

A surrogate-analyte LC-MS/MS method for cortisol in whole blood was validated, showing linearity from 0.5 to 500 ng/mL with acceptable accuracy and precision per regulatory guidance. Evaluation of patient samples demonstrated comparable cortisol concentrations in whole blood and plasma, indicating that whole blood sampling could support patient-centric, at-home collection in decentralised trials and clinical diagnostics.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    This study validated a lateral flow fluorescence assay using quantum dots for saliva and europium nanoparticles for serum to detect cortisol within physiological ranges. The test operates in 15 minutes with a handheld reader, supporting point-of-care and at-home monitoring without a cold chain.

    Ultrasensitive de novo Protein Sandwich Lateral flow Fluorescence Assay for Cortisol in Saliva and Serum using Quantum dots and Europium NanoparticlesBruno et al., Journal of fluorescence (paywalled) · source ↗

    • blood
    • saliva
    • liquid
    • self-collection
    • validation
    • hormones
    • cortisol
  2. 2023

    During ACTH stimulation, salivary cortisol correlated only weakly with serum and gave modest accuracy: saliva does not reliably replace serum cortisol for adrenal insufficiency. A concrete limit.

    Reliability of Salivary versus Serum Cortisol for Diagnosing Adrenal Insufficiency in ChildrenCiancia et al., Children · source ↗

    • venous-agreement
    • blood
    • cortisol
    • pediatric
    • hormones
    • liquid
    • validation
    • saliva
  3. 2026

    This study used home self-collected saliva samples to successfully monitor cytokines and cortisol in mothers and infants, finding that a community singing intervention significantly reduced salivary interleukin-6 levels in mothers with postnatal depression.

    Community singing intervention reduces maternal salivary cytokines and enhances maternal-infant cortisol synchrony in postnatal depression: biological findings from the SHAPER-PND trialKirkpatrick et al., Brain, behavior, and immunity (paywalled) · source ↗

    • dct
    • cortisol
    • self-collection
    • pediatric
    • hormones
    • liquid
    • saliva
    • biomarkers
  4. 2026

    This study found that salivary 11-dehydrodexamethasone correlates strongly with serum dexamethasone, unlike salivary dexamethasone which shows poor agreement. This validation suggests patients could self-collect saliva samples at home to verify dexamethasone absorption for the overnight suppression test.

    The Utility of Salivary 11-Dehydrodexamethasone as a Marker of Dexamethasone AbsorptionMarshall et al., The Journal of clinical endocrinology and metabolism (paywalled) · source ↗

    • venous-agreement
    • tdm
    • cortisol
    • self-collection
    • hormones
    • liquid
    • validation
    • saliva
  5. 2026

    A machine learning model called Remote Control was trained on 2685 blood samples to predict change due to instability, enabling accurate calibration of results to approximate the time zero value at collection. With calibration, unprocessed whole blood could be transported for up to 9 days under ambient conditions and temperatures between 3.4 and 47.4 degrees Celsius, achieving agreement with CLIA TEa between 98.1 and 100 per cent and expanding the catalog of tests available for at-home collection.

    Prolonging Sample Stability with Machine Learning Expands the Catalog of Tests Available for Mail-In Capillary Blood Collected At-HomeO'Meara et al., Analytical chemistry (paywalled) · source ↗

    • dct
    • blood
    • self-collection
    • capillary
    • liquid
    • validation
    • biomarkers