Skip to content
OpenSampling

2026 · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · paywalled

Toward needle-free lamotrigine monitoring: Proof-of-concept for saliva and dried saliva spot analysis by LC-MS/MS - a short communication

Ďurčová et al.

The finding, in our words

Saliva and dried saliva spot lamotrigine concentrations correlated strongly with plasma (R approximately 0.84 to 0.85), supporting saliva and DSS as needle-free alternatives for therapeutic drug monitoring.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    A UPLC-MS/MS method for linezolid and metabolites in oral fluid and VAMS capillary blood satisfied ICH M10 validation requirements. Linezolid concentrations correlated strongly with venous plasma in both matrices, offering a non‑invasive option for therapeutic drug monitoring, whereas metabolites were systematically underestimated in VAMS and seldom detectable in oral fluid, restricting metabolite measurement.

    Simultaneous quantification of linezolid and its metabolites (PNU-142300 and PNU-142586) in oral fluid and capillary blood by UPLC-MS/MS: method validation and clinical application using non-invasive sampling techniquesGonzález-Berdullas et al., Journal of translational medicine (paywalled) · source ↗

    • blood
    • saliva
    • dried
    • capillary
    • vams
    • validation
    • venous-agreement
    • tdm
    • antimicrobials
    • haematocrit
  2. 2026

    In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.

    Clinical Validation of Venetoclax Volumetric Microsampling in Leukemia, with Whole-Blood-to-Plasma Conversion and Self-Microsampling FeasibilityLevens et al., Clinical Pharmacokinetics (paywalled) · source ↗

    • vams
    • venous-agreement
    • blood
    • dbs
    • tdm
    • self-collection
    • haematocrit
    • dried
    • oncology
    • capillary
    • validation
  3. 2026

    Guidance on capillary-to-plasma conversion: method- and analyte-specific clinical validation with paired capillary–venous samples before reporting plasma-equivalent results.

    To Convert or Not to Convert? Official IATDMCT Guideline on Converting Capillary-Blood Microsampling Concentrations to Plasma ConcentrationsBoffel et al., Therapeutic Drug Monitoring (paywalled) · source ↗

    • venous-agreement
    • blood
    • tdm
    • standards
    • dried
    • capillary
    • validation
  4. 2026

    In lung and renal transplant recipients, VAMS sampling with LC-MS/MS quantification of mycophenolic acid and tacrolimus showed good linearity and accuracy, and with a haematocrit-adjusted conversion formula achieved clinical agreement in most samples; tacrolimus did not require haematocrit correction. The approach is virtually painless and enables richer sampling for more accurate drug exposure estimates, supporting decentralised therapeutic drug monitoring.

    Evaluation of hematocrit-adjusted conversion strategies for mycophenolic acid and tacrolimus monitoring using volumetric absorptive microsampling in lung and renal transplant recipientsJuan et al., Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques · source ↗

    • blood
    • dried
    • vams
    • neoteryx-mitra
    • validation
    • venous-agreement
    • tdm
    • immunosuppressants
    • haematocrit
  5. 2026

    This study found that volumetric absorptive microsampling shows satisfactory agreement with venous plasma for monitoring several antiseizure medications in paediatric patients. However, a blood-to-plasma conversion factor was required to estimate plasma concentrations for clobazam and carbamazepine metabolites due to poor capillary-to-plasma interchangeability.

    Volumetric Absorptive Microsampling (VAMS) for Therapeutic Drug Monitoring of Antiseizure Medications (ASMs) in Pediatric PatientsSimeoli et al., Pharmaceuticals (paywalled) · source ↗

    • blood
    • dried
    • vams
    • validation
    • venous-agreement
    • pediatric
    • tdm