Patterned Dried Blood Spot Cards for the Improved Sampling of Whole Blood
Baillargeon et al.
The finding, in our words
Patterned dried blood spot cards that use wax barriers to control blood flow reduced the haematocrit effect, delivering threefold better accuracy for haemoglobin and about 95 per cent recovery of sodium compared with standard cards, while also improving inter-card precision for amino acids. This approach makes quantitative blood sampling more reliable in limited-resource settings without cold-chain transport.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
In AML and CLL, 91% of VAMS venetoclax results fell within 20% of plasma after individualised haematocrit correction; in home sampling, 18 of 21 patients self-sampled independently and 76% of returned samples were analysable, which shows home microsampling is workable, though the authors ask for multicentre validation.
Levens et al., Clinical Pharmacokinetics (paywalled) · source ↗
This review found that volumetric microsampling devices, such as Mitra, HemaPEN, HemaXis DB10, and Tasso-M20, overcome haematocrit bias, whilst Telimmune plasma separation cards enable direct plasma collection without centrifugation. These technologies support patient-centric, decentralised sampling, though the authors note that clinical validation remains limited across different drugs and patient populations.
Huhn & Scherf-Clavel, Therapeutic drug monitoring (paywalled) · source ↗
Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.
Heughebaert et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗
This study found that measuring thyroid-stimulating hormone via dried blood spots and a volumetric device showed high agreement with serum results, with classification accuracy exceeding 96 per cent. The volumetric approach demonstrated improved reproducibility and stability, supporting its use for decentralised thyroid function monitoring.
Bornikowska et al., Practical laboratory medicine · source ↗
Capillary finger-stick dried blood spots demonstrated strong analytical agreement with venous serum for prostate-specific antigen (R² = 0.987) and remained stable for 31 days across a wide temperature range. This less invasive microsampling approach enables at-home self-collection, supporting decentralised screening and tele-diagnostics for prostate cancer.
van Vugt et al., The journal of applied laboratory medicine (paywalled) · source ↗