Diagnostic accuracy of the VISITECT CD4 lateral-flow assay for screening advanced HIV disease: a systematic review and meta-analysis
Gebremeskele et al.
The finding, in our words
In a meta-analysis of ten studies comprising 6962 people with HIV, the VISITECT CD4 lateral-flow assay showed high pooled sensitivity of 98% and 71% specificity against flow cytometry. Performance from capillary blood fingerstick sampling demonstrated comparable sensitivity to venous blood, supporting its potential for decentralised screening of advanced HIV disease.
A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.
The study validated a semi-quantitative protocol for Epstein-Barr virus serology using dried blood spots, demonstrating 98.8% sensitivity and 96.5% specificity compared to paired venous serum samples. The successful validation in a self-sampling cohort confirms the suitability of this patient-centric microsampling approach for large-scale seroprevalence studies and decentralised trials.
Capillary blood samples collected by staff or self-collected by participants showed strong correlation and clinically acceptable agreement with venipuncture for influenza haemagglutination inhibition titers. The small differences observed were not clinically meaningful, and adequate sample volume was achieved in most attempts, supporting the feasibility of decentralised serological testing.
Rick et al., Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology (paywalled) · source ↗
Capillary samples collected using dried blood spots and Mitra microsamplers showed strong agreement with venous plasma for quantifying IgG antibodies against most vaccine-preventable diseases. Sensitivity was high for the majority of pathogens, though the study noted that antibody stability declined at room temperature over time, favouring cold storage for longer durations.
Ombati et al., Scientific reports (paywalled) · source ↗
In a cohort of 62 participants evaluating home self-collection with the TassoPlus device, 38 returned samples, with 29% excluded due to insufficient plasma volume below 200 ΔL. Although viral load measurements in adequate samples correlated well with conventional testing (r = 0.800), the high failure rate and missed detection in low-volume viremic samples indicate that further technical refinements are necessary before clinical adoption.
The study found very strong correlation between venous blood collection and capillary VAMS using Mitra devices for detecting SARS-CoV-2 spike antibodies, with samples remaining stable at room temperature for several months. This enables reliable at-home, patient-centric serological testing for large-scale community surveillance and vaccine studies.
Mayer et al., Journal of immunological methods (paywalled) · source ↗