Skip to content
OpenSampling

2020 · Nutrition research and practice · open access

Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion

Kim et al.

The finding, in our words

In fifteen men consuming a controlled salt intake, second-void urine provided more reliable estimates of 24-hour urinary sodium excretion than first-void urine, with the sodium-to-potassium ratio in first-day second-void samples showing significant correlation with measured 24-hour output. This suggests spot second-void sampling could replace cumbersome 24-hour collections for sodium intake assessment in decentralised nutrition monitoring.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2024

    Concentration strategies for spiked and naturally present biomarkers in non-invasively collected first-void urine

    Adding polyethylene glycol to first-void urine before centrifugation markedly improved cell-free DNA recovery in the pellet, whereas low-speed centrifugation alone removed cellular DNA while keeping cell-free DNA in the supernatant. Pseudovirions pelleted reliably under all conditions, but the study revealed substantial variation between self-collected samples, highlighting the need for standardised protocols in decentralised HPV screening programmes.

    Téblick et al., European journal of medical research · source ↗

    • first-void
    • hpv
    • liquid-biopsy
    • liquid
    • urine
    • validation
    • biomarkers
  2. 2017

    First-void urine: A potential biomarker source for triage of high-risk human papillomavirus infected women

    The review concludes that first-void urine is a feasible source for molecular biomarkers, such as host and viral gene methylation, to triage high-risk HPV infections, offering a non-invasive and preferred method for women that may improve screening adherence.

    Van Keer et al., European journal of obstetrics, gynecology, and reproductive biology (paywalled) · source ↗

    • urine
    • first-void
    • self-collection
    • validation
    • hpv
    • biomarkers
    • liquid-biopsy
  3. 2017

    Inflammatory reaction found in prostate-specific material - method standardization and proposed optimal cut-off points

    The study standardises leukocyte and interleukin-6 measurements in first-void urine, expressed prostatic secretion and post-massage urine from 541 adults and defines ROC-based cut-offs to distinguish inflammatory from non-inflammatory prostate disease, enabling more precise treatment selection in decentralised settings.

    Korrovits et al., Andrology (paywalled) · source ↗

    • first-void
    • urine
    • validation
    • biomarkers
  4. 2015

    Optimization and validation of a chiral GC-MS method for the determination of free D-amino acids ratio in human urine: application to a gestational diabetes mellitus study

    The authors developed and validated a chiral GC-MS method to quantify D-amino acid ratios in 1 mL first-void urine samples. In a study of 40 pregnant women, those with gestational diabetes mellitus showed altered urinary D-amino acid profiles compared to controls, suggesting that minimally invasive urine metabolomics could support decentralised screening for pregnancy-related metabolic disorders.

    Lorenzo et al., Journal of pharmaceutical and biomedical analysis (paywalled) · source ↗

    • urine
    • first-void
    • validation
    • metabolome
    • biomarkers
  5. 2026

    Diagnostic Performance of HPV Testing Using Self-Collected Urine and Vaginal Samples for Detecting Cervical Precancer or Worse: A Meta-Analysis

    This meta-analysis found that HPV testing using self-collected vaginal and urine samples showed sensitivities of 88.6% and 81% for detecting cervical precancer. Using a standardised device for first-void urine increased sensitivity to 86.6%, supporting decentralised patient-centric screening, though data on specificity and specific commercial devices were not consistently reported.

    Hsiao et al., The journal of obstetrics and gynaecology research (paywalled) · source ↗

    • urine
    • first-void
    • self-collection
    • validation
    • hpv
    • sti