Skip to content
OpenSampling

2023 · Analytical chemistry · open access

Microfluidic Device for Patient-Centric Multiplexed Assays with Readout in Centralized Laboratories

Hauser et al.

The finding, in our words

The authors developed a capillary microfluidic device that captures multiple blood biomarkers at collection and dries them on-chip, enabling safe shipment to centralised laboratories for multiplexed analysis. This patient-centric approach could support remote health monitoring and decentralised trials.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2026

    Serial Dried Blood Spot C-Peptide Sampling, but Not Urine C-Peptide-to-Creatinine Ratio, Detects Early Preservation of β-Cell Function in New-Onset Type 1 Diabetes: Experience From the USTEKID Trial

    Frequent dried blood spot sampling detected early changes in beta-cell function more effectively than mixed-meal tolerance tests or urine ratios, supporting its potential as a decentralised monitoring tool for clinical trials.

    Dunseath et al., Diabetes care (paywalled) · source ↗

    • dct
    • blood
    • dbs
    • self-collection
    • dried
    • capillary
    • pediatric
    • urine
    • biomarkers
  2. 2025

    Quantitative Assessment of a Novel Device Designed for Patient-centric Sampling of Dried Plasma Using Targeted Proteomics

    Targeted proteomic evaluation of a novel finger-prick dried plasma device demonstrated strong quantitative correlation with conventional plasma (R = 0.99) and precision under 10% CV for 80% of quantified peptides across healthy donors. Quantified targets also remained stable during room temperature storage for up to 232 days, supporting its use for decentralised biomarker monitoring.

    Hober et al., Analytical chemistry · source ↗

    • blood
    • dried
    • capillary
    • self-collection
    • validation
    • venous-agreement
    • dct
    • biomarkers
  3. 2026

    Clinical validation of a DBS-based LC-MS/MS method for 25-hydroxyvitamin D: from lab sampling to home sampling

    Capillary dried blood spots, after haematocrit-dependent conversion, showed good agreement with plasma for 25-hydroxyvitamin D quantification, with 90 per cent of results within 20 per cent of plasma and substantial to almost perfect agreement in status classification, supporting reliable home self-collection for large-scale vitamin D monitoring.

    Heughebaert et al., Clinical chemistry and laboratory medicine (paywalled) · source ↗

    • venous-agreement
    • blood
    • dbs
    • self-collection
    • haematocrit
    • dried
    • capillary
    • validation
    • biomarkers
  4. 2026

    A minimally invasive dried blood spot biomarker test for the detection of Alzheimer's disease pathology

    The study found that capillary dried plasma spots correlated strongly with venous plasma for detecting the Alzheimer's disease biomarker p-tau217. This suggests that microsampling offers a viable, minimally invasive alternative to venipuncture for screening and monitoring Alzheimer's disease pathology.

    Huber et al., Nature medicine · source ↗

    • blood
    • dried
    • capillary
    • dbs
    • venous-agreement
    • biomarkers
  5. 2026

    Limited agreement of cytokines and CRP through patient-centric microsampling compared to venipuncture in healthy adults

    The study found that although participants preferred patient-centric microsampling devices for home use, the agreement with venous plasma for measuring CRP and cytokines was inconsistent, indicating that further validation is required before these methods replace standard venipuncture.

    Tuttle et al., Bioanalysis (paywalled) · source ↗

    • dct
    • venous-agreement
    • acceptability
    • blood
    • dbs
    • self-collection
    • dried
    • biomarkers