2020 · Sexually transmitted diseases · paywalled
Comparison of Assays for the Diagnosis of Mycoplasma genitalium and Macrolide Resistance Mutations in Self-Collected Vaginal Swabs and Urine
Chernesky et al.
The finding, in our words
A head-to-head comparison of three commercial assays on self-collected vaginal swabs and first-void urine from 300 women showed Aptima MG achieved 100% sensitivity for Mycoplasma genitalium on both specimen types, while ResistancePlus MG sensitivity fell to 83.3% on urine versus 100% on swabs, and Seeplex STD6 ACE performed poorly on both. This demonstrates that for decentralised STI diagnostics, both assay choice and specimen type profoundly affect accuracy, with vaginal swabs proving more reliable than urine for two of the three tests.