2022 · Frontiers in immunology · open access

A Wipe-Based Stool Collection and Preservation Kit for Microbiome Community Profiling

Hua et al.

The finding, in our words

A dissolvable wipe with DESS solution captured stool for metagenomics with high species-level agreement to frozen storage, R2 0.96, preserved Shannon diversity and species richness, and performed comparably to a commercial preservation kit, R2 0.98, enabling stable room temperature collection and transport for decentralised sampling.

A paraphrase to the Library’s standard, never the abstract. The source is one link away and is always the authority.

Labels

  1. 2021

    A study found that fecal samples on FOBT cards and RNAlater, and oral samples in Scope mouthwash, remained stable for four days at room temperature, with fecal comparability ICCs ranging from 0.63 to 0.93. These methods support decentralised sampling, though consistent method choice is required as each may introduce modest differences.

    Comparison of fecal and oral collection methods for studies of the human microbiota in two Iranian cohortsWu et al., BMC microbiology · source ↗

    • stabilised
    • self-collection
    • microbiome
    • stool
    • validation
    • saliva
  2. 2019

    This study compared four stool collection methods for infant gut microbiome analysis via post and found that the OMNIgene•GUT kit showed the closest agreement with the frozen standard compared to swabs or plain tubes. The findings suggest that stabilised collection offers a viable decentralised solution for parents to sample infant stool at home with minimal DNA degradation.

    Gut microbiome analysis by post: Evaluation of the optimal method to collect stool samples from infants within a national cohort studyWilliams et al., PloS one · source ↗

    • stool
    • stabilised
    • dna-genotek-omnigene
    • self-collection
    • validation
    • pediatric
    • microbiome
  3. 2018

    The OMNIgene•GUT kit proved reliable for stool microsampling and ambient storage, with samples stored at room temperature for seven days showing comparable bacterial DNA quantity and diversity to fresh samples; transient phylum-level differences were seen at 24 hours but not at seven days. This supports decentralised, patient-centric microbiome research by enabling home self-collection and postal transport, while emphasising that DNA extraction method has greater impact on microbiome profiles than storage conditions.

    Reliability of a participant-friendly fecal collection method for microbiome analyses: a step towards large sample size investigationSzopinska et al., BMC microbiology · source ↗

    • stool
    • stabilised
    • dna-genotek-omnigene
    • self-collection
    • validation
    • microbiome
  4. 2017

    Gammaproteobacteria proliferate in stool samples shipped at room temperature, distorting microbiome profiles. A computational correction method that removes sequences from these blooming taxa enables reliable microbiome analysis from self-collected samples sent without cold chain, producing results comparable to frozen specimens.

    Correcting for Microbial Blooms in Fecal Samples during Room-Temperature ShippingAmir et al., mSystems · source ↗

    • stool
    • stabilised
    • dna-genotek-omnigene
    • self-collection
    • validation
    • microbiome
  5. 2026

    Saliva samples collected using the OMNIgene ORAL device and oral wash samples remain stable for microbiome diversity and relative abundance analyses for up to five years when stored at -80°C. This supports the use of these self-collection methods for long-term prospective biobanking and decentralised clinical studies.

    Long-term stability at -80°C of oral wash and saliva samples for microbiome analysesSlack et al., Microbiology spectrum (paywalled) · source ↗

    • stabilised
    • dna-genotek-omnigene
    • self-collection
    • microbiome
    • liquid
    • validation
    • saliva